Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 94(5)2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-37184347

RESUMO

We report on progress implementing and testing cryogenically cooled platforms for Magnetized Liner Inertial Fusion (MagLIF) experiments. Two cryogenically cooled experimental platforms were developed: an integrated platform fielded on the Z pulsed power generator that combines magnetization, laser preheat, and pulsed-power-driven fuel compression and a laser-only platform in a separate chamber that enables measurements of the laser preheat energy using shadowgraphy measurements. The laser-only experiments suggest that ∼89% ± 10% of the incident energy is coupled to the fuel in cooled targets across the energy range tested, significantly higher than previous warm experiments that achieved at most 67% coupling and in line with simulation predictions. The laser preheat configuration was applied to a cryogenically cooled integrated experiment that used a novel cryostat configuration that cooled the MagLIF liner from both ends. The integrated experiment, z3576, coupled 2.32 ± 0.25 kJ preheat energy to the fuel, the highest to-date, demonstrated excellent temperature control and nominal current delivery, and produced one of the highest pressure stagnations as determined by a Bayesian analysis of the data.

2.
Rev Sci Instrum ; 89(10): 10F102, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399823

RESUMO

X-ray diffraction measurements to characterize phase transitions of dynamically compressed high-Z matter at Mbar pressures require both sufficient photon energy and fluence to create data with high fidelity in a single shot. Large-scale laser systems can be used to generate x-ray sources above 10 keV utilizing line radiation of mid-Z elements. However, the laser-to-x-ray energy conversion efficiency at these energies is low, and thermal x-rays or hot electrons result in unwanted background. We employ polycapillary x-ray lenses in powder x-ray diffraction measurements using solid target x-ray emission from either the Z-Beamlet long-pulse or the Z-Petawatt (ZPW) short-pulse laser systems at Sandia National Laboratories. Polycapillary lenses allow for a 100-fold fluence increase compared to a conventional pinhole aperture while simultaneously reducing the background significantly. This enables diffraction measurements up to 16 keV at the few-photon signal level as well as diffraction experiments with ZPW at full intensity.

3.
Rev Sci Instrum ; 89(10): 105106, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399920

RESUMO

Amplification of the transverse scattered component of stimulated Brillouin scattering (SBS) can contribute to optical damage in the large aperture optics of multi-kJ lasers. Because increased laser bandwidth from optical phase modulation (PM) can suppress SBS, high energy laser amplifiers are injected with PM light. Phase modulation distributes the single-frequency spectrum of a master oscillator laser among individual PM sidebands, so a sufficiently high modulation index ß can maintain the fluence for all spectral components below the SBS threshold. To avoid injection of single frequency light in the event of a PM failure, a high-speed PM failsafe system (PMFS) must be employed. Because PM is easily converted to AM, essentially all PM failsafes detect AM, with the one described here employing a novel configuration where optical heterodyne detection converts PM to AM, followed by passive AM power detection. Although the PMFS is currently configured for continuous monitoring, it can also detect PM for pulse durations ≥2 ns and could be modified to accommodate shorter pulses. This PMFS was deployed on the Z-Beamlet Laser (ZBL) at Sandia National Laboratories, as required by an energy upgrade to support programs at Sandia's Z Facility such as magnetized liner inertial fusion. Depending on the origin of a PM failure, the PMFS responds in as little as 7 ns. In the event of an instantaneous failure during initiation of a laser shot, this response time translates to a 30-50 ns margin of safety by blocking a pulse from leaving ZBL's regenerative amplifier, which prevents injection of single frequency light into the main amplification chain. The performance of the PMFS, without the need for operator interaction, conforms to the principles of engineered safety.

4.
Nat Commun ; 9(1): 280, 2018 01 18.
Artigo em Inglês | MEDLINE | ID: mdl-29348402

RESUMO

High-intensity lasers interacting with solid foils produce copious numbers of relativistic electrons, which in turn create strong sheath electric fields around the target. The proton beams accelerated in such fields have remarkable properties, enabling ultrafast radiography of plasma phenomena or isochoric heating of dense materials. In view of longer-term multidisciplinary purposes (e.g., spallation neutron sources or cancer therapy), the current challenge is to achieve proton energies well in excess of 100 MeV, which is commonly thought to be possible by raising the on-target laser intensity. Here we present experimental and numerical results demonstrating that magnetostatic fields self-generated on the target surface may pose a fundamental limit to sheath-driven ion acceleration for high enough laser intensities. Those fields can be strong enough (~105 T at laser intensities ~1021 W cm-2) to magnetize the sheath electrons and deflect protons off the accelerating region, hence degrading the maximum energy the latter can acquire.

5.
Phys Rev Lett ; 101(5): 055004, 2008 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-18764401

RESUMO

This Letter demonstrates the transporting and focusing of laser-accelerated 14 MeV protons by permanent magnet miniature quadrupole lenses providing field gradients of up to 500 T/m. The approach is highly reproducible and predictable, leading to a focal spot of (286 x 173) microm full width at half maximum 50 cm behind the source. It decouples the relativistic laser-proton acceleration from the beam transport, paving the way to optimize both separately. The collimation and the subsequent energy selection obtained are perfectly applicable for upcoming high-energy, high-repetition rate laser systems.

6.
Phys Rev Lett ; 95(24): 244503, 2005 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-16384385

RESUMO

To explore the validity of theories forwarded to explain the dynamics of hydrodynamic perturbations on high Mach number blast waves, we have studied the decay rate of perturbations on blast waves traveling through nitrogen gas. In our experiments, 1 kJ pulses from the Z-Beamlet laser at Sandia National Laboratories illuminated solid targets immersed in gas and created blast waves. The polytropic index implied by comparing experiment to theoretical predictions is compared to simulation results.

7.
Phys Rev Lett ; 90(3): 035005, 2003 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-12570498

RESUMO

Simulations of a double Z-pinch hohlraum, relevant to the high-yield inertial-confinement-fusion concept, predict that through geometry design the time-integrated P2 Legendre mode drive asymmetry can be systematically controlled from positive to negative coefficient values. Studying capsule elongation, recent experiments on Z confirm such control by varying the secondary hohlraum length. Since the experimental trend and optimum length are correctly modeled, confidence is gained in the simulation tools; the same tools predict capsule drive uniformity sufficient for high-yield fusion ignition.

8.
Phys Rev Lett ; 89(24): 245002, 2002 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-12484951

RESUMO

An inertial-confinement-fusion (ICF) concept using two 60-MA Z pinches to drive a cylindrical hohlraum to 220 eV has been recently proposed. The first capsule implosions relevant to this concept have been performed at the same physical scale with a lower 20-MA current, yielding a 70+/-5 eV capsule drive. The capsule shell shape implies a polar radiation symmetry, the first high-accuracy measurement of this type in a pulsed-power-driven ICF configuration, within a factor of 1.6-4 of that required for scaling to ignition. The convergence ratio of 14-21 is to date the highest in any pulsed-power ICF system.

9.
Mem Inst Oswaldo Cruz ; 92(1): 9-14, 1997.
Artigo em Inglês | MEDLINE | ID: mdl-9302406

RESUMO

Angiostrongylus costaricensis is a parasitic nematode of rodents and molluscs are the intermediate hosts. Nocturnal collection of molluscs and search for infective third stage larvae of A. costaricensis was carried out in 18 endemic foci identified by the notification of a confirmed diagnosis in human biopsies or surgical specimens. Molluscs were digested in acidic solution and isolation of larvae eventually present was done in a Baermann funnel. Larvae identified by the presence of a delicate groove in the tail were counted to assess the individual parasitic burden. Four species were found infected, with ranges of prevalence in parenthesis: Phyllocaulis variegatus (7% to 33.3%); Bradybaena similaris (11.7% to 24.1%); Belocaulus angustipes (8.3%) and Phyllocaulis soleiformis (3.3% to 14.2%). Parasitic burden varied from 1 to 75 with P. variegatus, 1 to 98 with B. similaris. 1 to 13 with B. angustipes and 1 larvae in each of two specimens of P. solciformis. P. variegatus was present in all sites and was found infected with the highest prevalence figures and the highest individual parasitic burdens. These data stress the importance of veronicellid slugs as intermediate hosts for A. costaricensis in the endemic areas in Rio Grande do Sul, Brazil.


Assuntos
Angiostrongylus , Doenças Endêmicas , Interações Hospedeiro-Parasita/imunologia , Moluscos/parasitologia , Infecções por Strongylida/epidemiologia , Infecções por Strongylida/parasitologia , Abdome , Animais , Brasil/epidemiologia , Humanos , Prevalência , Doenças dos Roedores/parasitologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...