Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Anal Chim Acta ; 1252: 341031, 2023 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-36935146

RESUMO

A novel method for near-infrared (NIR) spectroscopy spectra standardization is presented. NIR spectroscopies have been widely used in analytical chemistry, and many methods have been developed for NIR spectra standardization. To establish a robust standardization transformation, most existing methods require spectral data sets from both primal and secondary instruments for 1-1 correspondence validation. However, this limits the usage of standardization methods. This paper investigates an interesting issue, "Can spectra data in sets be arbitrarily order?" and further develops a completely different approach from existing methods in view of statistical signal processing. The key idea is to first compensate for the distortion along the wavelength and intensity of the spectra, and then transfer the second order statistic (2OS) from the primal spectra to the secondary spectra via data sphering and an inverse sphering transform so that the 2OS can be estimated regardless of the sample statistic order. To further demonstrate how the developed method can extend the usage of the NIR spectra standardization, several application-driven experiments on classification and regression are conducted for demonstration, and a comparison to the piecewise direct standardization (PDS) is also studied.

2.
Opt Express ; 25(22): 26885-26897, 2017 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-29092172

RESUMO

This is the first report of a simultaneous ultraviolet/visible/NIR and longwave infrared laser-induced breakdown spectroscopy (UVN + LWIR LIBS) measurement. In our attempt to study the feasibility of combining the newly developed rapid LWIR LIBS linear array detection system to existing rapid analytical techniques for a wide range of chemical analysis applications, two different solid pharmaceutical tablets, Tylenol arthritis pain and Bufferin, were studied using both a recently designed simultaneous UVN + LWIR LIBS detection system and a fast AOTF NIR (1200 to 2200 nm) spectrometer. Every simultaneous UVN + LWIR LIBS emission spectrum in this work was initiated by one single laser pulse-induced micro-plasma in the ambient air atmosphere. Distinct atomic and molecular LIBS emission signatures of the target compounds measured simultaneously in UVN (200 to 1100 nm) and LWIR (5.6 to 10 µm) spectral regions are readily detected and identified without the need to employ complex data processing. In depth profiling studies of these two pharmaceutical tablets without any sample preparation, one can easily monitor the transition of the dominant LWIR emission signatures from coating ingredients gradually to the pharmaceutical ingredients underneath the coating. The observed LWIR LIBS emission signatures provide complementary molecular information to the UVN LIBS signatures, thus adding robustness to identification procedures. LIBS techniques are more surface specific while NIR spectroscopy has the capability to probe more bulk materials with its greater penetration depth. Both UVN + LWIR LIBS and NIR absorption spectroscopy have shown the capabilities of acquiring useful target analyte spectral signatures in comparable short time scales. The addition of a rapid LWIR spectroscopic probe to these widely used optical analytical methods, such as NIR spectroscopy and UVN LIBS, may greatly enhance the capability and accuracy of the combined system for a comprehensive analysis.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA