1.
Clin Neurophysiol ; 132(3): 730-736, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33567379

RESUMO

OBJECTIVE: To study if limited frontotemporal electroencephalogram (EEG) can guide sedation changes in highly infectious novel coronavirus disease 2019 (COVID-19) patients receiving neuromuscular blocking agent. METHODS: 98 days of continuous frontotemporal EEG from 11 consecutive patients was evaluated daily by an epileptologist to recommend reduction or maintenance of the sedative level. We evaluated the need to increase sedation in the 6 h following this recommendation. Post-hoc analysis of the quantitative EEG was correlated with the level of sedation using a machine learning algorithm. RESULTS: Eleven patients were studied for a total of ninety-eight sedation days. EEG was consistent with excessive sedation on 57 (58%) and adequate sedation on 41 days (42%). Recommendations were followed by the team on 59% (N = 58; 19 to reduce and 39 to keep the sedation level). In the 6 h following reduction in sedation, increases of sedation were needed in 7 (12%). Automatized classification of EEG sedation levels reached 80% (±17%) accuracy. CONCLUSIONS: Visual inspection of a limited EEG helped sedation depth guidance. In a secondary analysis, our data supported that this determination may be automated using quantitative EEG analysis. SIGNIFICANCE: Our results support the use of frontotemporal EEG for guiding sedation in patients with COVID-19.


Assuntos
Tratamento Farmacológico da COVID-19 , Eletroencefalografia/métodos , Lobo Frontal/fisiologia , Hipnóticos e Sedativos/administração & dosagem , Aprendizado de Máquina , Lobo Temporal/fisiologia , Idoso , Anestesia/métodos , COVID-19/diagnóstico , COVID-19/fisiopatologia , Estudos de Coortes , Eletroencefalografia/efeitos dos fármacos , Feminino , Humanos , Unidades de Terapia Intensiva , Masculino , Pessoa de Meia-Idade
2.
Anesth Analg ; 109(3): 817-21, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19690251

RESUMO

Somatosensory-evoked potential (SSEP) monitoring is commonly used to detect changes in nerve conduction and prevent impending nerve injury. We present a case series of two patients who had SSEP monitoring for their surgical craniotomy procedure, and who, upon positioning supine with their head tilted 30 degrees-45 degrees, developed unilateral upper extremity SSEP changes. These SSEP changes were reversed when the patients were repositioned. These cases indicate the clinical usefulness of monitoring SSEPs while positioning the patient and adjusting position accordingly to prevent injury.


Assuntos
Craniotomia/métodos , Potenciais Somatossensoriais Evocados/fisiologia , Doenças do Sistema Nervoso/diagnóstico , Idoso , Anestesiologia/métodos , Eletrodos , Eletrofisiologia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória/métodos , Monitorização Fisiológica/métodos , Doenças do Sistema Nervoso/patologia , Valor Preditivo dos Testes
3.
Anesth Analg ; 99(5): 1334-1340, 2004 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-15502027

RESUMO

In this study we compared the effects of propofol, small-dose isoflurane, and nitrous oxide (N(2)O) on cortical somatosensory evoked potentials (SSEP) and bispectral index (BIS) monitoring in adolescents undergoing spinal fusion. Twelve patients received the following anesthetic maintenance combinations in a randomly determined order: treatment #1: isoflurane 0.4% + N(2)O 70% + O(2) 30%; treatment #2: isoflurane 0.6% + N(2)O 70% + O(2) 30%; treatment #3: isoflurane 0.6% + air + O(2) 30%; treatment #4: propofol 120 microg . kg(-1) . min(-1) + air + O(2) 30%. Cortical SSEP amplitudes measured during anesthesia maintenance with treatment #3 (isoflurane 0.6%/air) were more than those measured during maintenance with treatment #1 (isoflurane 0.4%/N(2)O 70%) (P < 0.0001) and treatment #2 (isoflurane 0.6%/N(2)O 70%) (P < 0.0052). Cortical SSEP amplitudes measured during treatment #4 (propofol 120 microg . kg(-1) . min(-1)/air) were more than treatment #1 (isoflurane 0.4%/N(2)O 70%) (P < 0.0001), treatment #2 (Iso 0.6%/N(2)O 70%) (P < 0.0007), and treatment #3 (isoflurane 0.6%/air) (P < 0.0191). In addition, average BIS values measured during treatments 1, 2, 3 and 4 were 62, 62, 61, and 44 respectively. Only treatment #4 (propofol 120 microg . kg(-1) . min(-1)/air) uniformly maintained BIS values less than 60. Our study demonstrates that propofol better preserves cortical SSEP amplitude measurement and provides a deeper level of hypnosis as measured by BIS values than combinations of small-dose isoflurane/N(2)O or small-dose isoflurane alone.


Assuntos
Anestésicos Inalatórios , Anestésicos Intravenosos , Eletroencefalografia/efeitos dos fármacos , Potenciais Somatossensoriais Evocados/efeitos dos fármacos , Isoflurano , Óxido Nitroso , Propofol , Fusão Vertebral , Adolescente , Criança , Feminino , Humanos , Masculino , Monitorização Intraoperatória , Escoliose/cirurgia