Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Animals (Basel) ; 13(11)2023 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-37889733

RESUMO

Cardiac adaptation to conditioning in horses was evaluated after empirical training based on trainers' experience. Twelve purebred Arabian horses, aged (mean ± SD) 28.42 ± 3.75 months, which did not perform any type of exercise prior to the research, were submitted to treadmill conditioning for six weeks. The conditioning program was based on the velocity run by the horse at which the blood lactate concentration, determined in an incremental exercise test (IET), reached 2 mmol/L (V2). The velocity at which the blood lactate concentration reached 4 mmol/L (V4) was also determined. The echocardiograms were performed at rest with pulsed-wave and tissue Doppler imaging in B- and M-modes. All procedures were carried out before and after the conditioning period. The results showed increases in V2 (from 5.2 ± 0.3 to 6.7 ± 0.4 m/s) and V4 (from 5.8 ± 0.4 to 7.6 ± 0.5 m/s) (p < 0.0001). There were also increases in the left ventricle internal diameter at diastole (LVIDd), left ventricle mass (LV mass), and stroke volume (SV), while no changes were observed in the LV free wall thickness and mean and relative wall thicknesses. The conditioning protocol, which was completed by all horses, proved to be safe and efficient, as it improved the aerobic capacity of the animals. Finally, the cardiac remodeling that occurred was mainly associated with the effect of physical training.

2.
Animals (Basel) ; 13(20)2023 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-37894014

RESUMO

The effect of lactate minimum speed (LMS)-guided training on horses' homeostasis is still unknown. Thus, this study aimed to evaluate the effect of an LMS-guided training program on the fluid, electrolyte and acid-base status of horses. Ten untrained Arabian horses were submitted to an LMS test on a treadmill before and after six weeks of training. The training intensity was 80% of the LMS in the first three sessions and 100% of the LMS in the other sessions. The venous blood was collected before (T-1) and after (T-2) training at rest, during and after the LMS test for lactate, pH, pCO2, HCO3-, and electrolyte measurements. The LMS and strong ion difference (SID4) were calculated. A mild increase in the mean values (p > 0.05) was observed at rest in T-2 in comparison with T-1 in the following variables: pH (from 7.436 ± 0.013 to 7.460 ± 0.012), pCO2 (from 42.95 ± 1.58 to 45.06 ± 0.81 mmHg), HCO3- (from 27.01 ± 1.02 to 28.91 ± 0.86 mmol/L), and SID4 (from 33.42 ± 1.45 to 35.06 ± 2.94 mmol/L). During T-2, these variables were more stable than during T-1. Despite the improvement in fitness, the LMS did not indicate a significant difference (from 5.40 ± 0.55 to 5.52 ± 0.20 m/s). The results confirmed that the LMS-guided training program had a positive impact on the horses' acid-base status, although some adaptations are still required to improve their fitness.

3.
Anal Chim Acta ; 625(1): 22-7, 2008 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-18721535

RESUMO

In this work, a new approach is presented to allow interference-free determination of Cu (II) by stripping voltammetry using the bismuth-film electrode. The addition of hydrogen peroxide to the electroanalytical cell has promoted complete resolution between re-dissolution peaks of Bi (III) and Cu (II). The absence of interference could be evaluated by the correlation coefficient (r>0.99) between Cu (II) concentration and its shifted current peak (at +212 mV) while achieving a slightly fluctuation of the bismuth current peak at -180 mV. Studies were performed aiming towards the optimum conditions for trace determination of Cu (II) using hydrogen peroxide. The methodology was applied to a real sample (sugarcane spirits) and the results were compared to those from graphite furnace atomic absorption spectrometry. The analytical parameters of merit and the results of the analysis indicated that the analytical methodology could be readily used for trace determination of Cu (II).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...