Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Ultrasound Obstet Gynecol ; 47(1): 58-64, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26415141

RESUMO

OBJECTIVES: Congenital cardiac malformations are commonly identified at perinatal autopsy, which can be challenging in fetuses of early gestation and in macerated fetuses. Our objective was to examine fetal complex congenital heart disease by microcomputed tomography (micro-CT), using standard autopsy as the gold standard. METHODS: In this ethically approved study, ex-vivo isolated fetal heart and fetal heart-lung blocks underwent iodine preparation prior to micro-CT, and were fixed in formalin after the micro-CT examination. Images were acquired using a microfocus-CT scanner with individual specimen image optimization. Twenty-one indices assessed normally at autopsy were evaluated for each dataset. Cardiac dissection was performed using a dissecting microscope within 24 h of the micro-CT examination. RESULTS: We examined six fetal hearts, comprising five with complex congenital cardiac malformations at a gestational age of 17-23 weeks and an anatomically normal heart of 23 weeks' gestation for reference. All specimens demonstrated excellent internal contrast at micro-CT examination, and the correct overall diagnosis was made in all cases. There was agreement for 114/126 indices assessed on micro-CT and at autopsy dissection (overall concordance of 95.8% (95% CI, 90.5-98.2%)). Micro-CT was particularly useful in the assessment of ventricular morphology in macerated fetuses. CONCLUSIONS: Micro-CT of small ex-vivo fetal specimens can provide highly accurate three-dimensional rendering of complex congenital fetal heart disease. This approach represents a significant advance in postmortem imaging and confirms the potential of this technology for non-invasive examination of small fetuses and organs.


Assuntos
Coração Fetal/diagnóstico por imagem , Cardiopatias Congênitas/diagnóstico , Autopsia/métodos , Dissecação , Feminino , Coração Fetal/patologia , Humanos , Masculino , Gravidez , Segundo Trimestre da Gravidez , Microtomografia por Raio-X
3.
Appl Opt ; 21(12): 2115-23, 1982 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-20395992

RESUMO

A compact vacuum ultraviolet spectrometer system has been developed to provide time-resolved impurity spectra from tokamak plasmas. Two interchangeable aberration-corrected toroidal diffraction gratings with flat focal fields provide simultaneous coverage over the ranges 100-1100 A or 160-1700 A. The detector is an intensified self-scanning photodiode array. Spectral resolution is 2 A with the higher dispersion grating. Minimum readout time for a full spectrum is 20 msec, but up to seven individual spectral lines can be measured with a 1-msec time resolution. The sensitivity of the system is comparable with that of a conventional grazing-incidence monochromator.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...