Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
PLoS One ; 13(8): e0202275, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30096188

RESUMO

Drug-resistant bacteria such as methicillin-resistant Staphylococcus aureus (MRSA) are a target for new antimicrobial technologies. Far-UVC technology is an emerging disinfection method that directly kills microorganisms using light. In contrast with conventional UV sterilization, far-UVC light has antimicrobial capabilities without apparent harm to mammalian cells. This study examines the application of 224 nm far-UVC light delivered from a laser using an optical diffuser towards the goal of protecting against bacterial invasion around skin penetrating devices. Delivery of far-UVC using a laser and optical fibers enables exposure to unique geometries that would otherwise be shielded when using a lamp. Testing of the bactericidal potential of diffusing the far-UVC laser output over a large area was tested and yielded qualitative area killing results. The killing of MRSA using this method was also examined using an in vitro survival assay. Results followed a classic log-linear disinfection model with a rate constant of k = 0.51 cm2/mJ, which corresponds to an inactivation cross section of D90 = 4.5 mJ/cm2. This study establishes far-UVC delivered from a laser through an optical diffuser as a viable solution for disinfection of susceptible regions such as around catheters, drivelines, or other skin penetrating medical devices.


Assuntos
Desinfecção/instrumentação , Desinfecção/métodos , Lasers , Staphylococcus aureus Resistente à Meticilina/efeitos da radiação , Fibras Ópticas , Raios Ultravioleta , Tecnologia de Fibra Óptica , Técnicas In Vitro
3.
PLoS One ; 13(2): e0192053, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29466457

RESUMO

BACKGROUND: Prevention of superficial surgical wound infections from drug-resistant bacteria such as methicillin resistant Staphylococcus aureus (MRSA) currently present major health care challenges. The majority of surgical site infections (SSI) are believed to be caused by airborne transmission of bacteria alighting onto the wound during surgical procedures. We have previously shown that far-ultraviolet C light in the wavelength range of 207-222 nm is significantly harmful to bacteria, but without damaging mammalian cells and tissues. It is important that the lamp be fitted with a filter to remove light emitted at wavelengths longer than 230 nm which are harmful. AIMS: Using a hairless mouse model of infection of superficial wounds, here we tested the hypothesis that 222-nm light kills MRSA alighting onto a superficial skin incisions as efficiently as typical germicidal light (254 nm), but without inducing skin damage. METHODS: To simulate the scenario wherein incisions are infected during surgical procedures as pathogens in the room alight on a wound, MRSA was spread on a defined area of the mouse dorsal skin; the infected skin was then exposed to UVC light (222 nm or 254 nm) followed by a superficial incision within the defined area, which was immediately sutured. Two and seven days post procedure, bactericidal efficacy was measured as MRSA colony formation unit (CFU) per gram of harvested skin whereas fixed samples were used to assess skin damage measured in terms of epidermal thickness and DNA photodamage. RESULTS: In the circumstance of superficial incisions infected with bacteria alighting onto the wound, 222-nm light showed the same bactericidal properties of 254-nm light but without the associated skin damage. CONCLUSIONS: Being safe for patient and hospital staff, our results suggested that far-UVC light (222 nm) might be a convenient approach to prevent transmission of drug-resistant infectious agents in the clinical setting.


Assuntos
Modelos Animais de Doenças , Staphylococcus aureus Resistente à Meticilina/patogenicidade , Infecções Estafilocócicas/prevenção & controle , Raios Ultravioleta , Ferimentos e Lesões/microbiologia , Animais , Contagem de Colônia Microbiana , Masculino , Staphylococcus aureus Resistente à Meticilina/isolamento & purificação , Camundongos , Camundongos Pelados , Infecções Estafilocócicas/microbiologia
4.
Sci Rep ; 8(1): 2752, 2018 02 09.
Artigo em Inglês | MEDLINE | ID: mdl-29426899

RESUMO

Airborne-mediated microbial diseases such as influenza and tuberculosis represent major public health challenges. A direct approach to prevent airborne transmission is inactivation of airborne pathogens, and the airborne antimicrobial potential of UVC ultraviolet light has long been established; however, its widespread use in public settings is limited because conventional UVC light sources are both carcinogenic and cataractogenic. By contrast, we have previously shown that far-UVC light (207-222 nm) efficiently inactivates bacteria without harm to exposed mammalian skin. This is because, due to its strong absorbance in biological materials, far-UVC light cannot penetrate even the outer (non living) layers of human skin or eye; however, because bacteria and viruses are of micrometer or smaller dimensions, far-UVC can penetrate and inactivate them. We show for the first time that far-UVC efficiently inactivates airborne aerosolized viruses, with a very low dose of 2 mJ/cm2 of 222-nm light inactivating >95% of aerosolized H1N1 influenza virus. Continuous very low dose-rate far-UVC light in indoor public locations is a promising, safe and inexpensive tool to reduce the spread of airborne-mediated microbial diseases.


Assuntos
Desinfecção/métodos , Vírus da Influenza A Subtipo H1N1/efeitos da radiação , Influenza Humana/prevenção & controle , Influenza Humana/transmissão , Raios Ultravioleta , Humanos , Viabilidade Microbiana
5.
Radiat Prot Dosimetry ; 176(4): 341-346, 2017 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-28338819

RESUMO

Measurement of ultraviolet (UV) radiation is important for human health, especially with the expanded usage of short wavelength UV for sterilization purposes. This work examines unlaminated Gafchromic EBT3 film for UV radiation monitoring. The authors exposed the film to select wavelengths in the UV spectrum, ranging from 207 to 328 nm, and measured the change in optical density. The response of the film is wavelength dependent, and of the wavelengths tested, the film was most sensitive to 254 nm light, with measurable values as low as 10 µJ/cm2. The film shows a dose-dependent response that extends over more than four orders of magnitude. The response of the film to short wavelength UV is comparable to the daily safe exposure limits for humans, thus making it valuable as a tool for passive UV radiation monitoring.


Assuntos
Dosimetria Fotográfica/métodos , Raios Ultravioleta , Calibragem , Humanos , Análise Espectral/métodos
6.
Radiat Res ; 187(4): 433-442, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-28140787

RESUMO

Anatomically accurate phantoms are useful tools for radiation dosimetry studies. In this work, we demonstrate the construction of a new generation of life-like mouse phantoms in which the methods have been generalized to be applicable to the fabrication of any small animal. The mouse phantoms, with built-in density inhomogeneity, exhibit different scattering behavior dependent on where the radiation is delivered. Computer models of the mouse phantoms and a small animal irradiation platform were devised in Monte Carlo N-Particle code (MCNP). A baseline test replicating the irradiation system in a computational model shows minimal differences from experimental results from 50 Gy down to 0.1 Gy. We observe excellent agreement between scattered dose measurements and simulation results from X-ray irradiations focused at either the lung or the abdomen within our phantoms. This study demonstrates the utility of our mouse phantoms as measurement tools with the goal of using our phantoms to verify complex computational models.


Assuntos
Materiais Biomiméticos/efeitos da radiação , Imagens de Fantasmas/veterinária , Radiometria/instrumentação , Radiometria/veterinária , Espalhamento de Radiação , Irradiação Corporal Total/veterinária , Animais , Simulação por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Camundongos , Modelos Biológicos , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/veterinária , Irradiação Corporal Total/instrumentação
7.
Radiat Res ; 187(4): 483-491, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-28225654

RESUMO

We have previously shown that 207-nm ultraviolet (UV) light has similar antimicrobial properties as typical germicidal UV light (254 nm), but without inducing mammalian skin damage. The biophysical rationale is based on the limited penetration distance of 207-nm light in biological samples (e.g. stratum corneum) compared with that of 254-nm light. Here we extended our previous studies to 222-nm light and tested the hypothesis that there exists a narrow wavelength window in the far-UVC region, from around 200-222 nm, which is significantly harmful to bacteria, but without damaging cells in tissues. We used a krypton-chlorine (Kr-Cl) excimer lamp that produces 222-nm UV light with a bandpass filter to remove the lower- and higher-wavelength components. Relative to respective controls, we measured: 1. in vitro killing of methicillin-resistant Staphylococcus aureus (MRSA) as a function of UV fluence; 2. yields of the main UV-associated premutagenic DNA lesions (cyclobutane pyrimidine dimers and 6-4 photoproducts) in a 3D human skin tissue model in vitro; 3. eight cellular and molecular skin damage endpoints in exposed hairless mice in vivo. Comparisons were made with results from a conventional 254-nm UV germicidal lamp used as positive control. We found that 222-nm light kills MRSA efficiently but, unlike conventional germicidal UV lamps (254 nm), it produces almost no premutagenic UV-associated DNA lesions in a 3D human skin model and it is not cytotoxic to exposed mammalian skin. As predicted by biophysical considerations and in agreement with our previous findings, far-UVC light in the range of 200-222 nm kills bacteria efficiently regardless of their drug-resistant proficiency, but without the skin damaging effects associated with conventional germicidal UV exposure.


Assuntos
Desinfecção/métodos , Staphylococcus aureus Resistente à Meticilina/efeitos da radiação , Pele/efeitos da radiação , Raios Ultravioleta , Animais , Diferenciação Celular/efeitos da radiação , Proliferação de Células/efeitos da radiação , DNA/efeitos da radiação , Dano ao DNA , Epiderme/anatomia & histologia , Epiderme/efeitos da radiação , Humanos , Queratinócitos/citologia , Queratinócitos/efeitos da radiação , Masculino , Camundongos , Camundongos Pelados , Radiodermite/etiologia , Radiodermite/metabolismo , Radiodermite/patologia , Pele/citologia , Pele/metabolismo , Pele/microbiologia , Terapia Ultravioleta
8.
Radiat Res ; 187(4): 465-475, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-28211757

RESUMO

Validation of biodosimetry assays is normally performed with acute exposures to uniform external photon fields. Realistically, exposure to a radiological dispersal device or reactor leak will include exposure to low dose rates and likely exposure to ingested radionuclides. An improvised nuclear device will likely include a significant neutron component in addition to a mixture of high- and low-dose-rate photons and ingested radionuclides. We present here several novel irradiation systems developed at the Center for High Throughput Minimally Invasive Radiation Biodosimetry to provide more realistic exposures for testing of novel biodosimetric assays. These irradiators provide a wide range of dose rates (from Gy/s to Gy/week) as well as mixed neutron/photon fields mimicking an improvised nuclear device.


Assuntos
Modelos Teóricos , Armas Nucleares , Exposição à Radiação/análise , Monitoramento de Radiação/métodos , Liberação Nociva de Radioativos , Radiometria/métodos , Animais , Sangue/efeitos da radiação , Relação Dose-Resposta à Radiação , Humanos , Camundongos , Nêutrons
9.
PLoS One ; 11(6): e0138418, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27275949

RESUMO

BACKGROUND: UVC light generated by conventional germicidal lamps is a well-established anti-microbial modality, effective against both bacteria and viruses. However, it is a human health hazard, being both carcinogenic and cataractogenic. Earlier studies showed that single-wavelength far-UVC light (207 nm) generated by excimer lamps kills bacteria without apparent harm to human skin tissue in vitro. The biophysical explanation is that, due to its extremely short range in biological material, 207 nm UV light cannot penetrate the human stratum corneum (the outer dead-cell skin layer, thickness 5-20 µm) nor even the cytoplasm of individual human cells. By contrast, 207 nm UV light can penetrate bacteria and viruses because these cells are physically much smaller. AIMS: To test the biophysically-based hypothesis that 207 nm UV light is not cytotoxic to exposed mammalian skin in vivo. METHODS: Hairless mice were exposed to a bactericidal UV fluence of 157 mJ/cm2 delivered by a filtered Kr-Br excimer lamp producing monoenergetic 207-nm UV light, or delivered by a conventional 254-nm UV germicidal lamp. Sham irradiations constituted the negative control. Eight relevant cellular and molecular damage endpoints including epidermal hyperplasia, pre-mutagenic UV-associated DNA lesions, skin inflammation, and normal cell proliferation and differentiation were evaluated in mice dorsal skin harvested 48 h after UV exposure. RESULTS: While conventional germicidal UV (254 nm) exposure produced significant effects for all the studied skin damage endpoints, the same fluence of 207 nm UV light produced results that were not statistically distinguishable from the zero exposure controls. CONCLUSIONS: As predicted by biophysical considerations and in agreement with earlier in vitro studies, 207-nm light does not appear to be significantly cytotoxic to mouse skin. These results suggest that excimer-based far-UVC light could potentially be used for its anti-microbial properties, but without the associated hazards to skin of conventional germicidal UV lamps.


Assuntos
Epiderme , Infecção da Ferida Cirúrgica/terapia , Raios Ultravioleta , Animais , Epiderme/metabolismo , Epiderme/microbiologia , Humanos , Masculino , Camundongos , Camundongos Pelados
10.
Radiat Res ; 184(4): 404-10, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26414507

RESUMO

We describe here an accelerator-based neutron irradiation facility, intended to expose blood or small animals to neutron fields mimicking those from an improvised nuclear device at relevant distances from the epicenter. Neutrons are generated by a mixed proton/deuteron beam on a thick beryllium target, generating a broad spectrum of neutron energies that match those estimated for the Hiroshima bomb at 1.5 km from ground zero. This spectrum, dominated by neutron energies between 0.2 and 9 MeV, is significantly different from the standard reactor fission spectrum, as the initial bomb spectrum changes when the neutrons are transported through air. The neutron and gamma dose rates were measured using a custom tissue-equivalent gas ionization chamber and a compensated Geiger-Mueller dosimeter, respectively. Neutron spectra were evaluated by unfolding measurements using a proton-recoil proportional counter and a liquid scintillator detector. As an illustration of the potential use of this facility we present micronucleus yields in single divided, cytokinesis-blocked human peripheral lymphocytes up to 1.5 Gy demonstrating 3- to 5-fold enhancement over equivalent X-ray doses. This facility is currently in routine use, irradiating both mice and human blood samples for evaluation of neutron-specific biodosimetry assays. Future studies will focus on dose reconstruction in realistic mixed neutron/photon fields.


Assuntos
Modelos Biológicos , Nêutrons , Guerra Nuclear , Animais , Humanos , Testes para Micronúcleos
11.
Nucl Instrum Methods Phys Res A ; 794: 234-239, 2015 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-26273118

RESUMO

A novel neutron irradiation facility at the Radiological Research Accelerator Facility (RARAF) has been developed to mimic the neutron radiation from an Improvised Nuclear Device (IND) at relevant distances (e.g. 1.5 km) from the epicenter. The neutron spectrum of this IND-like neutron irradiator was designed according to estimations of the Hiroshima neutron spectrum at 1.5 km. It is significantly different from a standard reactor fission spectrum, because the spectrum changes as the neutrons are transported through air, and it is dominated by neutron energies from 100 keV up to 9 MeV. To verify such wide energy range neutron spectrum, detailed here is the development of a combined spectroscopy system. Both a liquid scintillator detector and a gas proportional counter were used for the recoil spectra measurements, with the individual response functions estimated from a series of Monte Carlo simulations. These normalized individual response functions were formed into a single response matrix for the unfolding process. Several accelerator-based quasi-monoenergetic neutron source spectra were measured and unfolded to test this spectroscopy system. These reference neutrons were produced from two reactions: T(p,n)3He and D(d,n)3He, generating neutron energies in the range between 0.2 and 8 MeV. The unfolded quasi-monoenergetic neutron spectra indicated that the detection system can provide good neutron spectroscopy results in this energy range. A broad-energy neutron spectrum from the 9Be(d,n) reaction using a 5 MeV deuteron beam, measured at 60 degrees to the incident beam was measured and unfolded with the evaluated response matrix. The unfolded broad neutron spectrum is comparable with published time-of-flight results. Finally, the pair of detectors were used to measure the neutron spectrum generated at the RARAF IND-like neutron facility and a comparison is made to the neutron spectrum of Hiroshima.

12.
Radiat Environ Biophys ; 54(1): 137-144, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25335641

RESUMO

A noninvasive, self-referencing biosensor/probe system has been integrated into the Columbia University Radiological Research Accelerator Facility Microbeam II end station. A single-cell oxygen consumption measurement has been conducted with this type of oxygen probe in 37° C Krebs-Ringer Bicarbonate buffer immediately before and after a single-cell microbeam irradiation. It is the first such measurement made for a microbeam irradiation, and a six fold increment of oxygen flux induced during a 15-s period of time has been observed following radiation exposure. The experimental procedure and the results are discussed.


Assuntos
Técnicas Biossensoriais , Consumo de Oxigênio , Aceleradores de Partículas , Linhagem Celular , Eletrodos , Humanos , Radiobiologia/instrumentação
13.
Radiat Res ; 181(2): 146-61, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24502354

RESUMO

The development of, and results from an image analysis system are presented for automated detection and scoring of micronuclei in human peripheral blood lymphocytes. The system is part of the Rapid Automated Biodosimetry Tool, which was developed at the Center for High-Throughput Minimally Invasive Radiation Biodosimetry for rapid radiation dose assessment of many individuals based on single fingerstick samples of blood. Blood lymphocytes were subjected to the cytokinesis-block micronucleus assay and the images of cell cytoplasm and nuclei are analyzed to estimate the frequency of micronuclei in binucleated cells. We describe an algorithm that is based on dual fluorescent labeling of lymphocytes with separate analysis of images of cytoplasm and nuclei. To evaluate the performance of the system, blood samples of seven healthy donors were irradiated in vitro with doses from 0-10 Gy and dose-response curves of micronuclei frequencies were generated. To establish the applicability of the system to the detection of high doses, the ratios of mononucleated cells to binucleated cells were determined for three of the donors. All of the dose-response curves generated automatically showed clear dose dependence and good correlation (R(2) from 0.914-0.998) with the results of manual scoring.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imagem Molecular/métodos , Radiometria/métodos , Automação , Relação Dose-Resposta à Radiação , Humanos , Linfócitos/metabolismo , Linfócitos/efeitos da radiação , Testes para Micronúcleos , Software , Fatores de Tempo
14.
PLoS One ; 8(10): e76968, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24146947

RESUMO

BACKGROUND: 0.5% to 10% of clean surgeries result in surgical-site infections, and attempts to reduce this rate have had limited success. Germicidal UV lamps, with a broad wavelength spectrum from 200 to 400 nm are an effective bactericidal option against drug-resistant and drug-sensitive bacteria, but represent a health hazard to patient and staff. By contrast, because of its limited penetration, ~200 nm far-UVC light is predicted to be effective in killing bacteria, but without the human health hazards to skin and eyes associated with conventional germicidal UV exposure. AIMS: The aim of this work was to test the biophysically-based hypothesis that ~200 nm UV light is significantly cytotoxic to bacteria, but minimally cytotoxic or mutagenic to human cells either isolated or within tissues. METHODS: A Kr-Br excimer lamp was used, which produces 207-nm UV light, with a filter to remove higher-wavelength components. Comparisons were made with results from a conventional broad spectrum 254-nm UV germicidal lamp. First, cell inactivation vs. UV fluence data were generated for methicillin-resistant S. aureus (MRSA) bacteria and also for normal human fibroblasts. Second, yields of the main UV-associated pre-mutagenic DNA lesions (cyclobutane pyrimidine dimers and 6-4 photoproducts) were measured, for both UV radiations incident on 3-D human skin tissue. RESULTS: We found that 207-nm UV light kills MRSA efficiently but, unlike conventional germicidal UV lamps, produces little cell killing in human cells. In a 3-D human skin model, 207-nm UV light produced almost no pre-mutagenic UV-associated DNA lesions, in contrast to significant yields induced by a conventional germicidal UV lamp. CONCLUSIONS: As predicted based on biophysical considerations, 207-nm light kills bacteria efficiently but does not appear to be significantly cytotoxic or mutagenic to human cells. Used appropriately, 207-nm light may have the potential for safely and inexpensively reducing surgical-site infection rates, including those of drug-resistant origin.


Assuntos
Raios Ultravioleta , Sobrevivência Celular/efeitos da radiação , Dano ao DNA/efeitos da radiação , Humanos , Staphylococcus aureus Resistente à Meticilina/efeitos da radiação , Pele/metabolismo , Pele/microbiologia , Pele/efeitos da radiação , Infecção da Ferida Cirúrgica/prevenção & controle , Infecção da Ferida Cirúrgica/terapia , Terapia Ultravioleta/economia
15.
Rev Sci Instrum ; 84(5): 053701, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23742552

RESUMO

A novel technique for label-free imaging of live biological cells in aqueous medium that is insensitive to ambient vibrations is presented. This technique is a spin-off from previously developed immersion Mirau interferometry. Both approaches utilize a modified Mirau interferometric attachment for a microscope objective that can be used both in air and in immersion mode, when the device is submerged in cell medium and has its internal space filled with liquid. While immersion Mirau interferometry involves first capturing a series of images, the resulting images are potentially distorted by ambient vibrations. Overcoming these serial-acquisition challenges, simultaneous immersion Mirau interferometry incorporates polarizing elements into the optics to allow simultaneous acquisition of two interferograms. The system design and production are described and images produced with the developed techniques are presented.


Assuntos
Interferometria/instrumentação , Imagem Molecular/instrumentação , Células 3T3 , Animais , Desenho de Equipamento , Imersão , Luz , Camundongos , Fatores de Tempo , Vibração
16.
J Instrum ; 7(3)2012 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-22545061

RESUMO

Since the 1960s, the Radiological Research Accelerator Facility (RARAF) has been providing researchers in biology, chemistry and physics with advanced irradiation techniques, using charged particles, photons and neutrons.We are currently developing a unique facility at RARAF, to simulate neutron spectra from an improvised nuclear device (IND), based on calculations of the neutron spectrum at 1.5 km from the epicenter of the Hiroshima atom bomb. This is significantly different from a standard fission spectrum, because the spectrum changes as the neutrons are transported through air, and is dominated by neutron energies between 0.05 and 8 MeV. This facility will be based on a mixed proton/deuteron beam impinging on a thick beryllium target.A second, novel facility under development is our new neutron microbeam. The neutron microbeam will, for the first time, provide a kinematically collimated neutron beam, 10-20 micron in diameter. This facility is based on a Proton Microbeam, impinging on a thin lithium target near the threshold of the (7)Li(p,n)(7)Be reaction. This novel neutron microbeam will enable studies of neutron damage to small targets, such as single cells, individual organs within small animals or microelectronic components.

17.
J Instrum ; 72012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24058378

RESUMO

We fabricated ultrathin metal-semiconductor Schottky diodes for use as transmission particle detectors in the biological microbeam at Columbia University's Radiological Research Accelerator Facility (RARAF). The RARAF microbeam can deliver a precise dose of ionizing radiation in cell nuclei with sub-micron precision. To ensure an accurate delivery of charged particles, the facility currently uses a commercial charged-particle detector placed after the sample. We present here a transmission detector that will be placed between the particle accelerator and the biological specimen, allowing the irradiation of samples that would otherwise block radiation from reaching a detector behind the sample. Four detectors were fabricated with co-planar gold and aluminum electrodes thermally evaporated onto etched n-type crystalline silicon substrates, with device thicknesses ranging from 8.5 µm - 13.5 µm. We show coincident detections and pulse-height distributions of charged particles in both the transmission detector and the commercial detector above it. Detections are demonstrated at a range of operating conditions, including incoming particle type, count rate, and beam location on the detectors. The 13.5 µm detector is shown to work best to detect 2.7 MeV protons (H+), and the 8.5 µm detector is shown to work best to detect 5.4 MeV alpha particles (4He++). The development of a transmission detector enables a range of new experiments to take place at RARAF on radiation-stopping samples such as thick tissues, targets that need immersion microscopy, and integrated microfluidic devices for handling larger quantities of cells and small organisms.

18.
Nucl Instrum Methods Phys Res B ; 269(18): 1992-1996, 2011 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-21811347

RESUMO

A soft x-ray microbeam using proton-induced x-ray emission (PIXE) of characteristic titanium (K(α) 4.5 keV) as the x-ray source has been developed at the Radiological Research Accelerator Facility (RARAF) at Columbia University. The proton beam is focused to a 120 µm × 50 µm spot on the titanium target using an electrostatic quadrupole quadruplet previously used for the charged particle microbeam studies at RARAF. The proton induced x-rays from this spot project a 50 µm round x-ray generation spot into the vertical direction. The x-rays are focused to a spot size of 5 µm in diameter using a Fresnel zone plate. The x-rays have an attenuation length of (1/e length of ~145 µm) allowing more consistent dose delivery across the depth of a single cell layer and penetration into tissue samples than previous ultra soft x-ray systems. The irradiation end station is based on our previous design to allow quick comparison to charged particle experiments and for mixed irradiation experiments.

19.
Int J Radiat Biol ; 87(8): 776-90, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21557703

RESUMO

PURPOSE: Over the past five years the Center for Minimally Invasive Radiation Biodosimetry at Columbia University has developed the Rapid Automated Biodosimetry Tool (RABiT), a completely automated, ultra-high throughput biodosimetry workstation. This paper describes recent upgrades and reliability testing of the RABiT. MATERIALS AND METHODS: The RABiT analyses fingerstick-derived blood samples to estimate past radiation exposure or to identify individuals exposed above or below a cut-off dose. Through automated robotics, lymphocytes are extracted from fingerstick blood samples into filter-bottomed multi-well plates. Depending on the time since exposure, the RABiT scores either micronuclei or phosphorylation of the histone H2AX, in an automated robotic system, using filter-bottomed multi-well plates. Following lymphocyte culturing, fixation and staining, the filter bottoms are removed from the multi-well plates and sealed prior to automated high-speed imaging. Image analysis is performed online using dedicated image processing hardware. Both the sealed filters and the images are archived. RESULTS: We have developed a new robotic system for lymphocyte processing, making use of an upgraded laser power and parallel processing of four capillaries at once. This system has allowed acceleration of lymphocyte isolation, the main bottleneck of the RABiT operation, from 12 to 2 sec/sample. Reliability tests have been performed on all robotic subsystems. CONCLUSIONS: Parallel handling of multiple samples through the use of dedicated, purpose-built, robotics and high speed imaging allows analysis of up to 30,000 samples per day.


Assuntos
Bioensaio/instrumentação , Lesões por Radiação/diagnóstico , Radioisótopos/sangue , Radiometria/instrumentação , Robótica/instrumentação , Triagem/métodos , Análise Química do Sangue/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
20.
Radiat Res ; 175(3): 282-90, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21388271

RESUMO

The immunofluorescence-based detection of γ-H2AX is a reliable and sensitive method for quantitatively measuring DNA double-strand breaks (DSBs) in irradiated samples. Since H2AX phosphorylation is highly linear with radiation dose, this well-established biomarker is in current use in radiation biodosimetry. At the Center for High-Throughput Minimally Invasive Radiation Biodosimetry, we have developed a fully automated high-throughput system, the RABIT (Rapid Automated Biodosimetry Tool), that can be used to measure γ-H2AX yields from fingerstick-derived samples of blood. The RABIT workstation has been designed to fully automate the γ-H2AX immunocytochemical protocol, from the isolation of human blood lymphocytes in heparin-coated PVC capillaries to the immunolabeling of γ-H2AX protein and image acquisition to determine fluorescence yield. High throughput is achieved through the use of purpose-built robotics, lymphocyte handling in 96-well filter-bottomed plates, and high-speed imaging. The goal of the present study was to optimize and validate the performance of the RABIT system for the reproducible and quantitative detection of γ-H2AX total fluorescence in lymphocytes in a multiwell format. Validation of our biodosimetry platform was achieved by the linear detection of a dose-dependent increase in γ-H2AX fluorescence in peripheral blood samples irradiated ex vivo with γ rays over the range 0 to 8 Gy. This study demonstrates for the first time the optimization and use of our robotically based biodosimetry workstation to successfully quantify γ-H2AX total fluorescence in irradiated peripheral lymphocytes.


Assuntos
Histonas/metabolismo , Linfócitos/metabolismo , Radiometria/instrumentação , Adulto , Forma Celular , Tamanho Celular , Raios gama , Heparina/metabolismo , Humanos , Linfócitos/citologia , Linfócitos/efeitos da radiação , Microscopia de Fluorescência , Pessoa de Meia-Idade , Controle de Qualidade , Doses de Radiação , Radiometria/normas , Reprodutibilidade dos Testes , Robótica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...