Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Indian J Otolaryngol Head Neck Surg ; 76(1): 158-167, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38440628

RESUMO

To study and analyse the variations in ethmoid roof anatomy and estimate the anatomical location and variations of AEA on CT scans. The study is conducted on 200 patients for detailed analysis of the olfactory fossa (OF) depth, supraorbital pneumatisation, and AEA location and distance from the skull base. In our study, Keros type II was predominant type seen followed by type I. Asymmetry was noted in 32/200 subjects (16%). The anterior ethmoidal artery (AEA) canal was seen in 341/400 sides (85.2%). We found Keros type II was the most common type in our study. We also found grade I anterior ethmoidal artery as the most common variant and the dangerous grade III anterior ethmoidal artery was least common type found in this study, and there was a significant association of Keros type II with increasing anterior ethmoidal artery grading.

2.
Urol Ann ; 15(4): 373-382, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38074178

RESUMO

Introduction: Nephron-sparing surgery (NSS) is the standard of care for renal tumors, especially in the early stages. RENAL Nephrometry scores provide a comprehensive presurgical predictive module for the choice of NSS or Radical Nephrectomy. The validity and reliability of Nephrometry scores is being tested continuously with advancement in the surgical techniques. The Simplified PADUA Nephrometry score (SPARE NS) is a newer proposed score which aims to better the reproducibility of the previously established nephrometry scores. Materials and Methods: The retrospective observational study studied the comparative inter-observer reliability of RENAL (RENAL NS) and SPARE nephrometry scoring systems amongst two radiologists while assessing solid renal tumors in contrast-enhanced computed tomography scans of 42 patients. Interobserver reliability for all components of both scores, final scores and risk grading was done by Kendall's Concordance Coefficient (Tau). Results: Both RENAL NS and SPARE NS showed strong to excellent agreement (RENAL NS = 78.57% and SPARE NS = 88.09%) among observers with comparable correlation co-efficient (RENAL NS = 0.944 and SPARE NS = 0.935). Lesion radius and exophytic/endophytic properties were the most reproducible components of RENAL NS with 97.61% and 92.85% agreement, respectively. Location across polar lines was the least reproducible component with 85.71% agreement among observers. Exophytic rate (97.61%) and Rim location were the most reproducible components of SPARE NS. The final lesion risk stratification by both observers for both was concordant in 92.85% of cases. Conclusion: The SPARE system of scoring matches up to the RENAL NS in total score and risk stratification reproducibility. However, the individual components of the SPARE score are more reproducible than those of RENAL NS, bringing about better compliance among radiology consultants. Comparable reproducibility with the RENAL NS, lesser number of variables, and ease of doing make SPARE NS a plausible option for the customary preoperative assessment of renal tumors.

3.
Kidney360 ; 3(9): 1545-1555, 2022 09 29.
Artigo em Inglês | MEDLINE | ID: mdl-36245649

RESUMO

Background: Physical inactivity is common in patients receiving hemodialysis, but activity patterns throughout the day and in relation to dialysis are largely unknown. This knowledge gap can be addressed by long-term continuous activity monitoring, but this has not been attempted and may not be acceptable to patients receiving dialysis. Methods: Ambulatory patients with end-stage kidney disease receiving thrice-weekly hemodialysis wore commercially available wrist-worn activity monitors for 6 months. Step counts were collected every 15 minutes and were linked to dialysis treatments. Physical function was assessed using the Short Physical Performance Battery (SPPB). Fast time to recovery from dialysis was defined as ≤2 hours. Mixed effects models were created to estimate step counts over time. Results: Of 52 patients enrolled, 48 were included in the final cohort. The mean age was 60 years, and 75% were Black or Hispanic. Comorbidity burden was high, 38% were transported to and from dialysis by paratransit, and 79% had SPPB <10. Median accelerometer use (199 days) and adherence (95%) were high. Forty-two patients (of 43 responders) reported wearing the accelerometer every day, and few barriers to adherence were noted. Step counts were lower on dialysis days (3991 [95% CI, 3187 to 4796] versus 4561 [95% CI, 3757 to 5365]), but step-count intensity was significantly higher during the hour immediately after dialysis than during the corresponding time on nondialysis days (188 steps per hour increase [95% CI, 171 to 205]); these levels were the highest noted at any time. Postdialysis increases were more pronounced among patients with fast recovery time (225 [95% CI, 203 to 248] versus 134 [95% CI, 107 to 161] steps per hour) or those with SPPB ≥7. Estimates were unchanged after adjustment for demographics, diabetes status, and ultrafiltration rate. Conclusions: Long-term continuous monitoring of physical activity is feasible in patients receiving hemodialysis. Highly granular data collection and analysis yielded new insights into patterns of activity after dialysis treatments.


Assuntos
Monitores de Aptidão Física , Falência Renal Crônica , Monitorização Ambulatorial , Diálise Renal , Estudos de Coortes , Estudos de Viabilidade , Humanos , Falência Renal Crônica/terapia , Pessoa de Meia-Idade , Monitorização Ambulatorial/instrumentação , Monitorização Ambulatorial/métodos , Dispositivos Eletrônicos Vestíveis
4.
J Family Med Prim Care ; 11(6): 2938-2944, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36119172

RESUMO

Introduction: Vaccination against the global pandemic coronavirus disease 2019 (COVID-19) is a promising way out of the havoc caused by the disease. The clinico-radiological profile of COVID-19 patients in relation to the vaccination status is depicted in the present study. Materials and Methods: This is a retrospective observational imaging and hospital data-based study performed on 214 confirmed and clinically suspicious patients of COVID-19 who underwent high-resolution computed tomography (HRCT) scan of the thorax at the Department of Radio-Diagnosis of a tertiary medical center in the Himalayan foothills. The present study aims to evaluate the effect of vaccination on HRCT findings of COVID-19 populations. Results: Forty-three percent of the non-vaccinated population presented with severe HRCT scores (19-25) in comparison to only 11.5% of the study population who had taken both doses of vaccine (P = 0.018). Two doses of vaccination had a negative Pearson correlation coefficient with severe HRCT scores (-0.146). Co-morbidities had a significant correlation with HRCT severity score, with 61.5% diabetics and 63.33% of hypertensive patients showing scores >19 on HRCT. Conclusion: Vaccination proves to be a game changer in the pandemic with two doses of vaccination having a significant negative correlation with COVID-19-induced severe pneumonitis on HRCT of the thorax.

5.
BMC Nephrol ; 23(1): 74, 2022 02 22.
Artigo em Inglês | MEDLINE | ID: mdl-35193493

RESUMO

BACKGROUND: Patients with chronic kidney disease commonly experience gait abnormalities, which predispose to falls and fall-related injuries. An unmet need is the development of improved methods for detecting patients at high risk of these complications, using tools that are feasible to implement in nephrology practice. Our prior work suggested step length could be such a marker. Here we explored the use of step length as a marker of gait impairment and fall risk in adults with chronic kidney disease. METHODS: We performed gait assessments in 2 prospective studies of 82 patients with stage 4 and 5 chronic kidney disease (n = 33) or end-stage renal disease (ESRD) (n = 49). Gait speed and step length were evaluated during the 4-m walk component of the Short Physical Performance Battery (SPPB). Falls within 6 months prior to or following enrollment were identified by questionnaire. Associations of low step length (≤47.2 cm) and slow gait speed (≤0.8 m/s) with falls were examined using logistic regression models adjusted for demographics and diabetes and peripheral vascular disease status. RESULTS: Assessments of step length were highly reproducible (r = 0.88, p < 0.001 for duplicate measurements at the same visit; r = 0.78, p < 0.001 between baseline and 3-month evaluations). Patients with low step length had poorer physical function, including lower SPPB scores, slower gait speed, and lower handgrip strength. Although step length and gait speed were highly correlated (r = 0.73, p < 0.001), one-third (n = 14/43) of patients with low step length did not have slow gait speed. Low step length and slow gait speed were each independently associated with the likelihood of falls (odds ratio (OR) 3.90 (95% confidence interval (CI) 1.05-14.60) and OR 4.25 (95% CI 1.24-14.58), respectively). Compared with patients who exhibited neither deficit, those with both had a 6.55 (95% CI 1.40-30.71) times higher likelihood of falls, and the number of deficits was associated with a graded association with falls (p trend = 0.02). Effect estimates were similar after further adjustment for ESRD status. CONCLUSIONS: Step length and gait speed may contribute additively to the assessment of fall risk in a general adult nephrology population.


Assuntos
Acidentes por Quedas/estatística & dados numéricos , Análise da Marcha , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/fisiopatologia , Idoso , Feminino , Humanos , Falência Renal Crônica/complicações , Falência Renal Crônica/fisiopatologia , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos , Medição de Risco
6.
Nutrients ; 11(9)2019 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-31533272

RESUMO

The incidence of type 2 diabetes mellitus (DM) has increased in the US over the last several years. The consumption of low-fat dairy foods has been linked with decreasing the risk of DM but studies have yet to show a clear correlation. We conducted a systematic review and meta-analysis of randomized clinical trials (RCTs) evaluating the effects of dairy intake on homeostatic model assessment of insulin resistance (HOMA-IR), waist circumference, and body weight. In MEDLINE and Embase, we identified and reviewed 49 relevant RCTs: 30 had appropriate data format for inclusion in the meta-analysis. Using the Review Manager 5 software, we calculated the pooled standardized mean differences comparing dairy dietary interventions to control for our outcomes of interest. For HOMA-IR (794 individuals), we found a mean difference of -1.21 (95% CI -1.74 to -0.67; p-value < 0.00001; I2 = 92%). For waist circumference (1348 individuals), the mean difference was -1.09 cm (95% CI 1.68 to -0.58; p-value < 0.00001; I2 = 94%). For body weight (2362 individuals), the dairy intake intervention group weighed 0.42 kg less than control (p-value < 0.00001; I2 = 92%). Our findings suggest that dairy intake, especially low-fat dairy products, has a beneficial effect on HOMA-IR, waist circumference, and body weight. This could impact dietary recommendations to reduce DM risk.


Assuntos
Glicemia/metabolismo , Laticínios , Diabetes Mellitus Tipo 2/prevenção & controle , Dieta com Restrição de Gorduras , Gorduras na Dieta/administração & dosagem , Resistência à Insulina , Insulina/sangue , Valor Nutritivo , Adulto , Idoso , Biomarcadores/sangue , Diabetes Mellitus Tipo 2/sangue , Diabetes Mellitus Tipo 2/epidemiologia , Diabetes Mellitus Tipo 2/fisiopatologia , Gorduras na Dieta/metabolismo , Ingestão de Energia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ensaios Clínicos Controlados Aleatórios como Assunto , Recomendações Nutricionais , Circunferência da Cintura , Redução de Peso , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...