Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Transplant Direct ; 7(12): e789, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34805491

RESUMO

Perfusate lactate clearance (LC) is considered one of the useful indicators of liver viability assessment during normothermic machine perfusion (NMP); however, the applicable scope and potential mechanisms of LC remain poorly defined in the setting of liver donation after circulatory death. METHODS: The ex situ NMP of end-ischemic human livers was performed using the OrganOx Metra device. We further studied the extracellular signal-regulated kinases (phospho-extracellular signal-regulated kinase1/2 [pERK1/2]) pathway and several clinical parameters of these livers with successful LC (sLC, n = 5) compared with non-sLC (nLC, n = 5) in the perfusate (<2.2 mmol/L at 2 h, n = 5, rapid retrieval without normothermic regional perfusion). RESULTS: We found the pERK1/2 level was substantially higher in the nLC livers than in the sLC livers (n = 5) at 2- and 6-h NMP (P = 0.035 and P = 0.006, respectively). Immunostaining showed that upregulation of pERK1/2 was in both the hepatocytes and cholangiocytes in the nLC livers. Successful LC was associated with a marginally higher glycogen restoration than nLC at 2 h NMP (n = 5, P = 0.065). Furthermore, bile lactate levels in all sLC livers were cleared into the normal range at 6 h NMP, whereas in the nLC group, only 2 livers had lower bile lactate levels, and the other livers had rising bile lactate levels in comparison with the corresponding perfusate lactate levels. The necrosis scores were higher in the nLC than in the sLC livers (n = 5) at 0- and 6-h NMP (P = 0.047 and P = 0.053, respectively). CONCLUSIONS: The dual LC in perfusate and bile can be helpful in evaluating the hypoxic injury of hepatocytes and cholangiocytes during the NMP of donation after circulatory death in liver donors.

2.
Transpl Int ; 34(4): 709-720, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33462839

RESUMO

Transplantation of severely steatotic donor livers is associated with early allograft dysfunction and poorer graft survival. Histology remains the gold standard diagnostic of donor steatosis despite the lack of consensus definition and its subjective nature. In this prospective observational study of liver transplant patients, we demonstrate the feasibility of using a handheld optical backscatter probe to assess the degree of hepatic steatosis and correlate the backscatter readings with clinical outcomes. The probe is placed on the surface of the liver and emits red and near infrared light from the tip of the device and measures the amount of backscatter of light from liver tissue via two photodiodes. Measurement of optical backscatter (Mantel-Cox P < 0.0001) and histopathological scoring of macrovesicular steatosis (Mantel-Cox P = 0.046) were predictive of 5-year graft survival. Recipients with early allograft dysfunction defined according to both Olthoff (P = 0.0067) and MEAF score (P = 0.0097) had significantly higher backscatter levels from the donor organ. Backscatter was predictive of graft loss (AUC 0.75, P = 0.0045). This study demonstrates the feasibility of real-time measurement of optical backscatter in donor livers. Early results indicate readings correlate with steatosis and may give insight to graft outcomes such as early allograft dysfunction and graft loss.


Assuntos
Transplante de Fígado , Sobrevivência de Enxerto , Humanos , Fígado/diagnóstico por imagem , Projetos Piloto , Índice de Gravidade de Doença , Doadores de Tecidos
3.
Transplantation ; 104(5): 1019-1025, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31403552

RESUMO

BACKGROUND: The benefits of cold pulsatile machine perfusion (MP) for the storage and transportation of kidneys donated after circulatory death are disputed. We conducted a UK-based multicenter, randomized controlled trial to compare outcomes of kidneys stored with MP versus static cold storage (CS). METHODS: Fifty-one pairs of kidneys donated after circulatory death were randomly allocated to receive static CS or cold pulsatile MP. The primary endpoint, delayed graft function, was analyzed by "intention-to-treat" evaluation. RESULTS: There was no difference in the incidence of delayed graft function between CS and MP (32/51 (62.8%) and 30/51 (58.8%) P = 0.69, respectively), although the trial stopped early due to difficulty with recruitment. There was no difference in the incidence of acute rejection, or in graft or patient survival between the CS and MP groups. Median estimated glomerular filtration rate at 3 months following transplantation was significantly lower in the CS group compared with MP (CS 34 mL/min IQR 26-44 vs MP 45 mL/min IQR 36-60, P = 0.006), although there was no significant difference in estimated glomerular filtration rate between CS and MP at 12 months posttransplant. CONCLUSIONS: This study is underpowered, which limits definitive conclusions about the use of MP, as an alternative to static CS. It did not demonstrate that the use of MP reduces the incidence of delayed graft function in donation after circulatory death kidney transplantation.


Assuntos
Função Retardada do Enxerto/prevenção & controle , Transplante de Rim/métodos , Preservação de Órgãos/métodos , Perfusão/métodos , Doadores de Tecidos , Adolescente , Adulto , Idoso , Criopreservação/métodos , Função Retardada do Enxerto/epidemiologia , Função Retardada do Enxerto/fisiopatologia , Feminino , Seguimentos , Taxa de Filtração Glomerular/fisiologia , Sobrevivência de Enxerto , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Reino Unido/epidemiologia , Adulto Jovem
4.
Am J Transplant ; 19(6): 1745-1758, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30589499

RESUMO

Livers from controlled donation after circulatory death (DCD) donors suffer a higher incidence of nonfunction, poor function, and ischemic cholangiopathy. In situ normothermic regional perfusion (NRP) restores a blood supply to the abdominal organs after death using an extracorporeal circulation for a limited period before organ recovery. We undertook a retrospective analysis to evaluate whether NRP was associated with improved outcomes of livers from DCD donors. NRP was performed on 70 DCD donors from whom 43 livers were transplanted. These were compared with 187 non-NRP DCD donor livers transplanted at the same two UK centers in the same period. The use of NRP was associated with a reduction in early allograft dysfunction (12% for NRP vs. 32% for non-NRP livers, P = .0076), 30-day graft loss (2% NRP livers vs. 12% non-NRP livers, P = .0559), freedom from ischemic cholangiopathy (0% vs. 27% for non-NRP livers, P < .0001), and fewer anastomotic strictures (7% vs. 27% non-NRP, P = .0041). After adjusting for other factors in a multivariable analysis, NRP remained significantly associated with freedom from ischemic cholangiopathy (P < .0001). These data suggest that NRP during organ recovery from DCD donors leads to superior liver outcomes compared to conventional organ recovery.


Assuntos
Transplante de Fígado/métodos , Preservação de Órgãos/métodos , Adolescente , Adulto , Idoso , Doenças dos Ductos Biliares/prevenção & controle , Ductos Biliares/irrigação sanguínea , Criança , Morte , Função Retardada do Enxerto/prevenção & controle , Circulação Extracorpórea , Feminino , Sobrevivência de Enxerto , Humanos , Isquemia/prevenção & controle , Transplante de Fígado/efeitos adversos , Masculino , Pessoa de Meia-Idade , Preservação de Órgãos/efeitos adversos , Perfusão/métodos , Estudos Retrospectivos , Temperatura , Coleta de Tecidos e Órgãos/efeitos adversos , Coleta de Tecidos e Órgãos/métodos , Obtenção de Tecidos e Órgãos/métodos , Adulto Jovem
5.
Transplantation ; 101(5): 1084-1098, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28437389

RESUMO

BACKGROUND: A program of normothermic ex situ liver perfusion (NESLiP) was developed to facilitate better assessment and use of marginal livers, while minimizing cold ischemia. METHODS: Declined marginal livers and those offered for research were evaluated. Normothermic ex situ liver perfusion was performed using an erythrocyte-based perfusate. Viability was assessed with reference to biochemical changes in the perfusate. RESULTS: Twelve livers (9 donation after circulatory death [DCD] and 3 from brain-dead donors), median Donor Risk Index 2.15, were subjected to NESLiP for a median 284 minutes (range, 122-530 minutes) after an initial cold storage period of 427 minutes (range, 222-877 minutes). The first 6 livers were perfused at high perfusate oxygen tensions, and the subsequent 6 at near-physiologic oxygen tensions. After transplantation, 5 of the first 6 recipients developed postreperfusion syndrome and 4 had sustained vasoplegia; 1 recipient experienced primary nonfunction in conjunction with a difficult explant. The subsequent 6 liver transplants, with livers perfused at lower oxygen tensions, reperfused uneventfully. Three DCD liver recipients developed cholangiopathy, and this was associated with an inability to produce an alkali bile during NESLiP. CONCLUSIONS: Normothermic ex situ liver perfusion enabled assessment and transplantation of 12 livers that may otherwise not have been used. Avoidance of hyperoxia during perfusion may prevent postreperfusion syndrome and vasoplegia, and monitoring biliary pH, rather than absolute bile production, may be important in determining the likelihood of posttransplant cholangiopathy. Normothermic ex situ liver perfusion has the potential to increase liver utilization, but more work is required to define factors predicting good outcomes.


Assuntos
Seleção do Doador , Hiperóxia/etiologia , Transplante de Fígado/métodos , Perfusão/métodos , Complicações Pós-Operatórias/etiologia , Vasoplegia/etiologia , Isquemia Quente/métodos , Adulto , Idoso , Isquemia Fria , Seguimentos , Humanos , Hiperóxia/prevenção & controle , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Perfusão/efeitos adversos , Complicações Pós-Operatórias/prevenção & controle , Vasoplegia/prevenção & controle , Isquemia Quente/efeitos adversos
7.
Liver Transpl ; 21(4): 487-99, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25545865

RESUMO

Ischemia/reperfusion injury (IRI) that develops after liver implantation may prejudice long-term graft survival, but it remains poorly understood. Here we correlate the severity of IRIs that were determined by histological grading of time-zero biopsies sampled after graft revascularization with patient and graft outcomes. Time-zero biopsies of 476 liver transplants performed at our center between 2000 and 2010 were graded as follows: nil (10.5%), mild (58.8%), moderate (26.1%), and severe (4.6%). Severe IRI was associated with donor age, donation after circulatory death, prolonged cold ischemia time, and liver steatosis, but it was also associated with increased rates of primary nonfunction (9.1%) and retransplantation within 90 days (22.7%). Longer term outcomes in the severe IRI group were also poor, with 1-year graft and patient survival rates of only 55% and 68%, respectively (cf. 90% and 93% for the remainder). Severe IRI on the time-zero biopsy was, in a multivariate analysis, an independent determinant of 1-year graft survival and was a better predictor of 1-year graft loss than liver steatosis, early graft dysfunction syndrome, and high first-week alanine aminotransferase with a positive predictive value of 45%. Time-zero biopsies predict adverse clinical outcomes after liver transplantation, and severe IRI upon biopsy signals the likely need for early retransplantation.


Assuntos
Transplante de Fígado/efeitos adversos , Traumatismo por Reperfusão/patologia , Adulto , Fatores Etários , Idoso , Alanina Transaminase/sangue , Aloenxertos , Biomarcadores/sangue , Biópsia , Isquemia Fria/efeitos adversos , Feminino , Sobrevivência de Enxerto , Humanos , Estimativa de Kaplan-Meier , Transplante de Fígado/mortalidade , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Valor Preditivo dos Testes , Modelos de Riscos Proporcionais , Traumatismo por Reperfusão/sangue , Traumatismo por Reperfusão/etiologia , Traumatismo por Reperfusão/mortalidade , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Doadores de Tecidos , Resultado do Tratamento , Adulto Jovem
8.
Transplantation ; 98(6): 612-7, 2014 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-25029386

RESUMO

INTRODUCTION: Phosphodiesterase-5 inhibitors prevent the breakdown of cyclic guanosine 3',5'-monophosphate (cGMP) and therefore may be useful in reducing the detrimental effects of ischemia-reperfusion (I/R) injury. The aim of this study was to assess the effects of the phosphodiesterase-5 inhibitor sildenafil, on I/R injury in a porcine model of donation after circulatory death kidney transplantation. METHODS: Kidneys were subjected to 20 min warm ischemia followed by 2 or 18 hr of cold storage (n=6 kidneys per group). After preservation kidneys were reperfused on an ex vivo perfusion system for 3 hr with an oxygenated blood based solution. Kidneys were treated with 1.4 mg/kg sildenafil infused 10 min before and for 20 min after reperfusion (n=6 kidneys per group). Renal function and injury markers were measured throughout reperfusion. RESULTS: Prolonged cold ischemia (CI) significantly reduced levels of cGMP (2 hr 3.5 [1.5-5.7] vs. 18 hr 1.2 [0.3-2.8] pmol/mL; P=0.010). The administration of sildenafil significantly increased the levels (P=0.047, 0.064). Sildenafil improved the renal blood flow for the first 30 min in the 2-hr group (sildenafil, 81.8 [43.8-101.9] vs. control 40.2 [6.4-76.9] mL/min/100 g; P=0.026) and up to 60 min in the 18-hr group (sildenafil, 67.4 [38.0-87.0] vs. control 36.2 [30.5-50.0] mL/min/100 g; P=0.009) during reperfusion. Renal function was significantly impaired after 18-hr CI (P=0.0.26), and treatment with sildenafil did not improve renal function in the 2-hr (P=0.384) or 18-hr CI (P=0.099) groups. CONCLUSION: Sildenafil had a vasodilatory action and increased levels of cGMP but did not affect recovery of renal function or protect against I/R injury.


Assuntos
Transplante de Rim/métodos , Rim/efeitos dos fármacos , Piperazinas/efeitos adversos , Sulfonas/efeitos adversos , Animais , Área Sob a Curva , Isquemia Fria , Creatina/sangue , GMP Cíclico/metabolismo , Endotelina-1/sangue , Óxido Nítrico/metabolismo , Inibidores da Fosfodiesterase 5/efeitos adversos , Purinas/efeitos adversos , Circulação Renal/efeitos dos fármacos , Traumatismo por Reperfusão/prevenção & controle , Citrato de Sildenafila , Suínos , Fatores de Tempo , Isquemia Quente
9.
Transplantation ; 97(12): 1272-8, 2014 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-24646774

RESUMO

BACKGROUND: Over 40% of deceased donors in the UK donate after circulatory death (DCD). Normothermic regional perfusion has been reported to improve outcomes in such donors in Europe and the United States. Unlike the United States, legal and professional requirements in the UK prevent cannulation and heparinization before verification of death, which must be a minimum of 5 min after circulatory arrest. We developed a novel protocol for in situ normothermic regional perfusion (NRP) which complied with these requirements. METHODS: NRP was achieved by cannulating the aorta and vena cava after death. Donor blood was then warmed and oxygenated using a bespoke extracorporeal membrane oxygenator circuit before return to the donor. A shunt was incorporated into the extracorporeal circuit to permit heparin mixing before oxygenation and warming was commenced to prevent thrombosis of the oxygenator. Normothermic perfusion was continued for 2 hr before in situ cold perfusion with preservation fluid. All organs were subject to static cold storage after recovery. RESULTS: Eight controlled DCD donors underwent NRP from which 3 livers, 2 pancreases, and 14 kidneys were transplanted. Four livers were not used because of biochemical evidence of hepatocellular damage and one because of cirrhosis. Two kidneys were lost from venous thrombosis before function returned and two developed delayed graft function; all transplanted livers and pancreases had primary function. CONCLUSIONS: Cannulation and heparinization after circulatory arrest does not prevent successful normothermic regional perfusion. The technique permits evaluation of donor organs before implantation and may improve short-term outcomes.


Assuntos
Anticoagulantes/administração & dosagem , Oxigenação por Membrana Extracorpórea , Heparina/administração & dosagem , Preservação de Órgãos/métodos , Perfusão/métodos , Doadores de Tecidos/provisão & distribuição , Coleta de Tecidos e Órgãos/métodos , Adulto , Idoso , Aorta , Cateterismo , Causas de Morte , Isquemia Fria , Função Retardada do Enxerto/etiologia , Seleção do Doador , Esquema de Medicação , Oxigenação por Membrana Extracorpórea/efeitos adversos , Humanos , Transplante de Rim/efeitos adversos , Transplante de Fígado/efeitos adversos , Pessoa de Meia-Idade , Preservação de Órgãos/efeitos adversos , Transplante de Pâncreas , Perfusão/efeitos adversos , Fatores de Tempo , Coleta de Tecidos e Órgãos/efeitos adversos , Resultado do Tratamento , Veias Cavas , Trombose Venosa/etiologia , Trombose Venosa/prevenção & controle , Adulto Jovem
10.
J Transplant ; 2013: 605326, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24062943

RESUMO

Poiseuille's equation describes the relationship between fluid viscosity, pressure, tubing diameter, and flow, yet it is not known if cold organ perfusion systems follow this equation. We investigated these relationships in an ex vivo model and aimed to offer some rationale for equipment selection. Increasing the cannula size from 14 to 20 Fr increased flow rate by a mean (SD) of 13 (12)%. Marshall's hyperosmolar citrate was three times less viscous than UW solution, but flows were only 45% faster. Doubling the bag pressure led to a mean (SD) flow rate increase of only 19 (13)%, not twice the rate. When external pressure devices were used, 100 mmHg of continuous pressure increased flow by a mean (SD) of 43 (17)% when compared to the same pressure applied initially only. Poiseuille's equation was not followed; this is most likely due to "slipping" of preservation fluid within the plastic tubing. Cannula size made little difference over the ranges examined; flows are primarily determined by bag pressure and fluid viscosity. External infusor devices require continuous pressurisation to deliver high flow. Future studies examining the impact of perfusion variables on graft outcomes should include detailed equipment descriptions.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...