Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
PLoS One ; 11(12): e0167548, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27936027

RESUMO

Nanomaterials can be synthesized from a wide range of material systems in numerous morphologies, creating an extremely diverse portfolio. As result of this tunability, these materials are emerging as a new class of nanotherapeutics and imaging agents. One particularly interesting nanomaterial is the gold nanoparticle. Due to its inherent biocompatibility and tunable photothermal behavior, it has made a rapid transition from the lab setting to in vivo testing. In most nanotherapeutic applications, the efficacy of the agent is directly related to the target of interest. However, the optimization of the AuNP size and shape for efficacy in vitro, prior to testing in in vivo models of a disease, has been largely limited to two dimensional monolayers of cells. Two dimensional cell cultures are unable to reproduce conditions experienced by AuNP in the body. In this article, we systematically investigate the effect of different properties of AuNP on the penetration depth into 3D cell spheroids using two-photon microscopy. The 3D spheroids are formed from the HCT116 cell line, a colorectal carcinoma cell line. In addition to studying different sizes and shapes of AuNPs, we also study the effect of an oligo surface chemistry. There is a significant difference between AuNP uptake profiles in the 2D monolayers of cells as compared to the 3D cell spheroids. Additionally, the range of sizes and shapes studied here also exhibit marked differences in uptake penetration depth and efficacy. Finally, our results demonstrate that two-photon microscopy enables quantitative AuNP localization and concentration data to be obtained at the single spheroid level without fluorescent labeling of the AuNP, thus, providing a viable technique for large scale screening of AuNP properties in 3D cell spheroids as compared to tedious and time consuming techniques like electron microscopy.


Assuntos
Ouro/análise , Nanopartículas Metálicas/análise , Esferoides Celulares/citologia , Técnicas de Cultura de Células/métodos , Ouro/metabolismo , Células HCT116 , Humanos , Nanopartículas Metálicas/ultraestrutura , Microscopia Confocal/métodos , Imagem Óptica/métodos , Permeabilidade , Esferoides Celulares/metabolismo , Células Tumorais Cultivadas/metabolismo
2.
Sci Rep ; 5: 13795, 2015 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-26333806

RESUMO

We present a continuous-flow droplet-based digital Enzyme-Linked Oligonucleotide Hybridization Assay (droplet digital ELOHA) for sensitive detection and absolute quantification of RNA molecules. Droplet digital ELOHA incorporates direct hybridization and single enzyme reaction via the formation of single probe-RNA-probe (enzyme) complex on magnetic beads. It enables RNA detection without reverse transcription and PCR amplification processes. The magnetic beads are subsequently encapsulated into a large number of picoliter-sized droplets with enzyme substrates in a continuous-flow device. This device is capable of generating droplets at high-throughput. It also integrates in-line enzymatic incubation and detection of fluorescent products. Our droplet digital ELOHA is able to accurately quantify (differentiate 40% difference) as few as ~600 RNA molecules in a 1 mL sample (equivalent to 1 aM or lower) without molecular replication. The absolute quantification ability of droplet digital ELOHA is demonstrated with the analysis of clinical Neisseria gonorrhoeae 16S rRNA to show its potential value in real complex samples.


Assuntos
Ensaio de Imunoadsorção Enzimática/métodos , Separação Imunomagnética/métodos , Hibridização In Situ/métodos , RNA/genética , Análise de Sequência de RNA/métodos , Sequência de Bases , Dados de Sequência Molecular , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
Lab Chip ; 15(3): 776-82, 2015 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-25431886

RESUMO

Digital nucleic acid detection is rapidly becoming a popular technique for ultra-sensitive and quantitative detection of nucleic acid molecules in a wide range of biomedical studies. Digital polymerase chain reaction (PCR) remains the most popular way of conducting digital nucleic acid detection. However, due to the need for thermocycling, digital PCR is difficult to implement in a streamlined manner on a single microfluidic device, leading to complex fragmented workflows and multiple separate devices and instruments. Loop-mediated isothermal amplification (LAMP) is an excellent isothermal alternative to PCR with potentially better specificity than PCR because of the use of multiple primer sets for a nucleic acid target. Here we report a microfluidic droplet device implementing all the steps required for digital nucleic acid detection including droplet generation, incubation and in-line detection for digital LAMP. As compared to microchamber or droplet array-based digital assays, the continuous flow operation of this device eliminates the constraints on the number of total reactions imposed by the footprint of the device and the analysis throughput caused by the time for lengthy incubation and transfer of materials between instruments.


Assuntos
DNA/análise , Técnicas Analíticas Microfluídicas , Técnicas de Amplificação de Ácido Nucleico , Reação em Cadeia da Polimerase , Temperatura , DNA/genética , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas de Amplificação de Ácido Nucleico/instrumentação , Tamanho da Partícula , Reação em Cadeia da Polimerase/instrumentação
4.
Anal Chem ; 87(3): 1950-6, 2015 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-25543856

RESUMO

Application of droplet microfluidics to combinatorial screening applications remains elusive because of the need for composition-identifying unique barcodes. Here we propose a barcode-free continuous flow droplet microfluidic platform to suit the requirements of combinatorial screening applications. We demonstrate robust and repeatable functioning of this platform with matrix metalloproteinase activity screening as a sample application.


Assuntos
Ensaios Enzimáticos/instrumentação , Metaloproteinases da Matriz/metabolismo , Técnicas Analíticas Microfluídicas/instrumentação , Desenho de Equipamento , Metaloproteinases da Matriz/análise
5.
J Lab Autom ; 17(5): 370-7, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22885789

RESUMO

There is an increasing demand for novel high-throughput screening (HTS) technologies in the pharmaceutical and biotechnological industries. The robotic sample-handling techniques currently used in these industries, although fast, are still limited to operating in multiwell plates with the sample volumes per reaction in the microliter regime. Digital microfluidics offers an alternative for reduction in sample volume consumption for HTS but lacks a reliable technique for transporting a large number of samples to the microfluidic device. In this report, we develop a technique for serial delivery of sample arrays to a microfluidic device from multiwell plates, through a single sample inlet. Under this approach, a serial array of sample plugs, separated by an immiscible carrier fluid, is loaded into a capillary and delivered to a microfluidic device. Similar approaches have been attempted in the past, however, either with a slower sample loading device such as a syringe pump or vacuum-based sample loading with limited driving pressure. We demonstrated the application of our positive-pressure-based serial sample loading (SSL) system to load a series of sample plugs into a capillary. The adaptability of the SSL system to generate sample plugs with a variety of volumes in a predictable manner was also demonstrated.


Assuntos
Automação Laboratorial/métodos , Ensaios de Triagem em Larga Escala/métodos , Técnicas Analíticas Microfluídicas/métodos , Manejo de Espécimes/métodos , Biotecnologia/métodos , Humanos , Robótica , Tecnologia Farmacêutica/métodos
6.
Lab Chip ; 12(18): 3341-7, 2012 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-22842841

RESUMO

In this article we present a novel droplet microfluidic chip enabling amplification-free detection of single pathogenic cells. The device streamlines multiple functionalities to carry out sample digitization, cell lysis, probe-target hybridization for subsequent fluorescent detection. A peptide nucleic acid fluorescence resonance energy transfer probe (PNA beacon) is used to detect 16S rRNA present in pathogenic cells. Initially the sensitivity and quantification abilities of the platform are tested using a synthetic target mimicking the actual expression level of 16S rRNA in single cells. The capability of the device to perform "sample-to-answer" pathogen detection of single cells is demonstrated using E. coli as a model pathogen.


Assuntos
Escherichia coli/isolamento & purificação , Microfluídica/métodos , Escherichia coli/metabolismo , Transferência Ressonante de Energia de Fluorescência , Microfluídica/instrumentação , Hibridização de Ácido Nucleico , Ácidos Nucleicos Peptídicos/química , Ácidos Nucleicos Peptídicos/metabolismo , RNA Ribossômico 16S/metabolismo
7.
Lab Chip ; 12(17): 3055-62, 2012 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-22810353

RESUMO

We propose a highly versatile and programmable nanolitre droplet-based platform that accepts an unlimited number of sample plugs from a multi-well plate, performs digitization of these sample plugs into smaller daughter droplets and subsequent synchronization-free, robust injection of multiple reagents into the sample daughter droplets on-demand. This platform combines excellent control of valve-based microfluidics with the high-throughput capability of droplet microfluidics. We demonstrate the functioning of a proof-of-concept device which generates combinatorial mixture droplets from a linear array of sample plugs and four different reagents, using food dyes to mimic samples and reagents. Generation of a one dimensional array of the combinatorial mixture droplets on the device leads to automatic spatial indexing of these droplets, precluding the need to include a barcode in each droplet to identify its contents. We expect this platform to further expand the range of applications of droplet microfluidics to include applications requiring a high degree of multiplexing as well as high throughput analysis of multiple samples.


Assuntos
Técnicas Analíticas Microfluídicas/instrumentação , Desenho de Equipamento , Corantes de Alimentos/química , Tensoativos/química
8.
J Am Chem Soc ; 133(18): 6898-901, 2011 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-21504160

RESUMO

Single-molecule free solution hydrodynamic separation (SML-FSHS) cohesively integrates cylindrical illumination confocal spectroscopy with free solution hydrodynamic separation. This technique enables single-molecule analysis of size separated DNA with 100% mass detection efficiency, high sizing resolution and wide dynamic range, surpassing the performance of single molecule capillary electrophoresis. Furthermore, SML-FSHS required only a bare fused silica microcapillary and simple pressure control rather than complex high voltage power supplies, sieving matrices, and wall coatings. The wide dynamic range and high sizing resolution of SML-FSHS was demonstrated by separating both large DNA (23 vs 27 kbp) and small DNA (100 vs 200 bp) under identical conditions. Separations were successfully performed with near zero sample consumption using as little as 5 pL of sample and 240 yoctomoles (∼150 molecules) of DNA. Quantitative accuracy was predominantly limited by molecular shot noise. Furthermore, the ability of this method to analyze of single molecule nanosensors was investigated. SML-FSHS was used to examine the thermodynamic equilibrium between stochastically open molecular beacon and target-bound molecular beacon in the detection of E. coli 16s rRNA targets.


Assuntos
Cromatografia/métodos , DNA/isolamento & purificação , Análise Espectral/métodos , Cromatografia/instrumentação , DNA/química , Hidrodinâmica , Soluções , Análise Espectral/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...