1.
Modern Clinical Nursing ; (6): 9-12, 2017.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-511976

RESUMO

Objective To explore the effect of blood circulation punching apparatus on important vital signs and thrombus of lower extremity veins in stable blood pressure and normal cardiopulmonary function patients with cerebrovascular disease and hypertension and to evaluate safety and effectiveness of the apparatus for these patients.Methods We treated 30 patients with cerebrovascular disease and hypertension by blood circulation punching apparatus for 3 days,2 times per day,30 minutes per time.We monitored vital signs of these patients 15 minutes pre-,intra-and post-treatment.The thrombus of lower extremity veins and adverse reactions were observed during the treatment.Results We compared systolic pressure,diastolic pressure,pulse and breathe of patients 15 minutes pre-,intra-and post-treatment respectively.We didn't find any significant differences between these parameters.No patient had thrombus of lower extremity veins and adverse reactions in the hospital.Conclusion The blood circulation punching apparatus is suitable for cerebrovascular and hypertension patients with stable blood pressure and normal cardiopulmonary function and can prevent thrombus of lower extremity veins effectively.

2.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-498586

RESUMO

Objective To investigate the problems during using, standard and quality management of the POCT glucose meters in hospital, to analyze the solutions, and to provide reference data for improving the test level of POCT in hospital.Methods The amount, brand and application of portable glucose meters in the hospital were obtained by 3 rounds of surveillance from May to July in 2013.All of those glucose meters were taken part in external quality assessment of Clinical Laboratory Center of National Health and Family Planning Commission.The test results of those glucose meters were compared with that of automatic biochemical analyzer, the comparison results were then analyzed.Results The POCT glucose meters possessed 5 brands in our hospital, and the amount and type of glucose meters in some clinical departments were often changed.When 4 brands which were detected as quality control samples by ministry of health, the accuracy of detection results of 3 concentration of brand Ⅲ were substandard, the CV% of two levels were 11.9%and 10.1%respectively, the remaining 3 brands were in line with the requirements.The qualified percentages of 3 times of comparison were 85.0%, 92.0%and 97.4%.Conclusions The hospital should select the brand of portable glucose meters reasonably, correct use of glucose meters, and it is very necessary to build indoor and interstitial quality evaluation system, at the same time, suggesting the hospital to establish the POCT quality management team, to carry out the instrument comparison periodically, so to guarantee the accurate, reliable results of POCT in hospital.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...