Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nanotechnology ; 35(1)2023 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-37783203

RESUMO

Metallic nanoparticles and carbon nanotubes are two of the most promising nanomaterials, due to their distinctive properties occurring from spatial confinement of electron-hole pairs. The unique combination of metallic nanoparticles and carbon nanotubes (CNTs) in a polymer matrix offers unparalleled advantages, making them highly desirable in various fields. Advanced methods and techniques for synthesizing and characterizing hybrid metal-CNT-polymer nanocomposites have undergone significant progress in recent years, paving their integration into various fields, including aerospace, electronics, energy, water treatment and environmental remediation. These advances have allowed better understanding of nanocomposite properties and imparted ability to tune specific properties through size, shape, and distribution control of the nanofillers within the matrix material or by altering filler properties through functionalization. This study aims to critically judge the emerging tools, techniques and methods used in polymer nanocomposites with specific focus on metal-CNT based hybrid polymer nanocomposites, and suggest new avenues for research in the field. Furthermore, by examining the mechanisms affecting the performance of these composites, we can understand how the inclusion of fillers alters the microstructure and overall behavior of the material. Ultimately, this knowledge could lay the foundation for the development of novel nanocomposites with tailored properties and enhanced performance in a plethora of applications.

2.
ACS Appl Mater Interfaces ; 15(42): 49427-49435, 2023 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-37830921

RESUMO

Contact resistance (RC) in organic devices originates from a mismatch in energy levels between injecting electrodes and organic semiconductors (OSCs). However, the microscopic effects governing charge transfer between electrodes and the OSCs have not been analyzed in detail. We fabricated transistors with different OSCs (PTB7, PCDTBT, and PTB7-Th) and electrodes (MoO3, Au, and Ag) and measured their contact resistance. Regardless of the electrodes, devices with PTB7-Th exhibit the lowest values of RC. To explain the trends observed, first-principles computations were performed on contact interfaces based on the projector operator diabatization method. Our results revealed that differences in energy levels and the electronic couplings between OSCs' highest occupied molecular orbitals and vacant states on the electrodes influence device RC. Further, based on values obtained from the first-principles, the rate of charge transfer between OSCs and electrodes is calculated and found to correlate strongly with trends in RC for devices with different OSCs. We thus show that device RC is governed by the feasibility of charge transfer at the contact interface and hence determined by energy levels and electronic coupling among orbitals and states located on OSCs and electrodes.

3.
ACS Omega ; 6(27): 17413-17423, 2021 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-34278127

RESUMO

The development of a nanoparticle-based optical platform has been presented as a biosensor for detecting target-specific plant virus DNA. The binding dynamics of gold nanoparticles has been studied on the amine-functionalized surface by the attenuated total reflection (ATR)-based evanescent wave absorption method monitoring the localized surface plasmon resonance (LSPR). The developed surface was established as a refractive index sensor by monitoring the LSPR absorption peak of gold nanoparticles. This nanoparticle-immobilized surface was explored to establish as a biosensing platform with target-specific immunoglobulin (IgG) antibody-antigen interaction. The IgG concentration-dependent variation of absorbance was correlated with the refractive index change. After successfully establishing this ATR configuration as an LSPR-based biosensor, the single-stranded DNA of the chilli leaf curl virus was detected using its complementary DNA sequence as a receptor. The limit of detection of this sensor was determined to be 1.0 µg/mL for this target viral DNA. This ATR absorption technique has enormous potential as an LSPR based nano-biosensor for the detection of other begomoviruses.

4.
Analyst ; 145(3): 917-928, 2020 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-31820747

RESUMO

The high energy density (4.2 MJ kg-1) and low vapour pressure (7.2 × 10-9 atm) of chemical explosives such as TNT (2,4,6-trinitrotoluene) pose a grave security risk demanding immediate attention. Detection of such hazardous and highly challenging chemicals demands specific, ultra-sensitive and rapid detection platforms that can concomitantly transduce the signal as an electrical readout. Although chemo-sensitive strategies have been investigated, the majority of them are restricted to detecting TNT from solutions and are therefore not implementable in real-time, on-field situations. Addressing this demand, we report an ultra-sensitive (parts-per-billion) and rapid (∼40 s) detection platform for TNT based on non-covalently functionalized graphene field effect transistors (GFETs). This multi-parametric GFET detector exhibits a reliable and specific modulation in its Dirac point upon exposure to TNT in the vapour phase. The chemical specificity provided by 5-(4-hydroxyphenyl)-10,15,20-tri(p-tolyl) zinc porphyrin (ZnTTPOH) is synergistically combined with the high surface sensitivity of graphene through a non-covalent functionalization approach to realise p-doped GFETs (Zn-GFETs). Such a FET platform exhibits extremely sensitive shifts in Dirac point (ΔDP) that correlate with the number of nitro groups present in the analyte. Analytes with mono-, di-, and tri-nitro substituted aromatic molecules exhibit distinctly different ΔDP, leading to unprecedented specificity towards TNT. Additionally, the Dirac point of Zn-GFETs is invariant for common and potential interferons such as acetone and 2-propanol (perfume emulsifiers) thereby validating their practical applicability. Furthermore, the ΔDP is also manifested as changes in the contact potential of GFETs, indicating that sub-monolayer coverage of ZnTTPOH is sufficient to modulate the transfer characteristics of GFETs over an area 1000 times larger than the dopant dimensions. Specifically, ZnTTPOH-functionalized GFETs exhibit p-doped behaviour with positive ΔDP with respect to pristine GFETs. Such p-doped Zn-GFETs undergo selective charge-transfer mediated interactions with TNT resulting in enhanced electron withdrawal from Zn-GFETs. Thus the ΔDP shifts to a higher positive gate voltage leading to the dichotomous combination of the highest signal generation (1.2 × 1012 V mol-1) with ppb level molecular sensitivity. Significantly, the signal generated due to TNT is 105 times higher in magnitude compared to other potential interferons. The signal reliability is established in cross-sensitivity measurements carried out with a TNT-mDNB (1 : 10 molar ratio) mixture pointing to high specificity for immediate applications under atmospherically relevant conditions pertaining to homeland security and global safety.

5.
ACS Appl Mater Interfaces ; 11(12): 12017-12026, 2019 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-30821954

RESUMO

Organic molecular monolayers (MoLs) have been used for improving the performance of various electronic device structures. In this work, the concept of organic molecular surface modification is applied for improving the performance of GaN-based metal-semiconductor-metal (MSM) ultraviolet (UV) photodetectors (PDs). Organic molecules of phenol-functionalized metallated porphyrin (hydroxyl-phenyl-zinc-tetra-phenyl-porphyrin (Zn-TPPOH)) were adsorbed on GaN, and Ni/Zn-TPPOH/GaN/Zn-TPPOH/Ni PD structures were fabricated. This process was beneficial in two ways: first, the reverse-bias dark current was reduced by 1000 times, and second, the photocurrent was enhanced by ∼100 times, in comparison to the dark and photocurrent values obtained for Ni/GaN/Ni MSM PDs, at high voltages of ±10 V. The responsivity of the devices was increased from 0.22 to 4.14 kA/W at 5 µW/cm2 optical power density at -10 V bias and at other voltages also. In addition to this, other PD parameters such as photo-to-dark current ratio and UV-to-visible rejection ratio were also enhanced. The spectral selectivity of the PDs was improved, which means that the molecularly modified devices became more responsive to UV spectral region and less responsive to visible spectral region, in comparison to bare GaN-based devices. Photoluminescence measurements, power-dependent photocurrent characteristics, and time-resolved photocurrent measurements revealed that the MoL was passivating the defect-related states on GaN. In addition, Kelvin probe force microscopy showed that the MoL was also playing with the surface charge (due to surface states) on GaN, leading to increased Schottky barrier height in dark conditions. Resultant to both these phenomena, the reverse-bias dark current was reduced for metal/MoL/GaN/MoL/metal PD structures. Further, the unusual photoconductive gain in the molecularly modified devices has been attributed to Schottky barrier lowering for UV-illuminated conditions, leading to enhanced photocurrent.

6.
Sci Rep ; 7: 43905, 2017 03 02.
Artigo em Inglês | MEDLINE | ID: mdl-28252113

RESUMO

Distinguishing a specific biomarker from a biofluid sample containing a large variety of proteins often requires the selective preconcentration of that particular biomarker to a detectable level for analysis. Low-cost, paper-based device is an emerging opportunity in diagnostics. In the present study, we report a novel Zinc oxide nanorods functionalized paper platform for the preconcentration of Myoglobin, a cardiac biomarker. Zinc oxide nanorods were grown on a Whatman filter paper no. 1 via the standard hydrothermal route. The growth of Zinc oxide nanorods on paper was confirmed by a combination of techniques consisting of X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS,) scanning electron microscopy (SEM), and energy dispersive spectroscopy (EDX) analysis. The Zinc oxide nanorods modified Whatman filter paper (ZnO-NRs/WFP) was further tested for use as a protein preconcentrator. Paper-based ELISA was performed for determination of pre-concentration of cardiac marker protein Myoglobin using the new ZnO-NRs/WFP platform. The ZnO-NRs/WFP could efficiently capture the biomarker even from a very dilute solution (Myoglobin < 50 nM). Our ELISA results show a threefold enhancement in protein capture with ZnO-NRs/WFP compared to unmodified Whatman filter paper, allowing accurate protein analysis and showing the diagnostic concept.


Assuntos
Cromatografia em Papel/métodos , Mioglobina/isolamento & purificação , Nanotubos , Papel , Óxido de Zinco/metabolismo , Humanos
7.
ACS Appl Mater Interfaces ; 5(24): 13448-56, 2013 Dec 26.
Artigo em Inglês | MEDLINE | ID: mdl-24320549

RESUMO

A new benzimidazole-functionalized calix[4]arene receptor (R) was synthesized and characterized. The receptor R shows better selectivity toward trinitrotoluene (TNT) compared to the other nitro explosives in solution, which also retains its effectiveness for solid-phase detection. The chemical interactions of the molecule with different nitro explosive analytes were studied by fluorescence spectroscopy and by a molecular dynamics approach. The molecular dynamics studies show a 1:3 complex between R and TNT, and hence high sensitivity was imparted by fluorescence studies. The detection of explosive vapors in ambient conditions was tested by using a sensitive coating layer of R on an SU-8/CB-based piezoresistive cantilever surface. The developed device showed large sensitivity toward TNT compared to cyclotrimethylenetrinitramine (RDX) and pentaerythritol tetranitrate (PETN) in the solid state at their respective vapor pressures at room temperature. The detection sensitivity of the device was estimated to be 35 mV for TNT at ambient conditions. Moreover, the sensor does not show a response when exposed to humidity. These results demonstrate that R can be used as one of the coating materials for a cantilever for the detection of TNT using piezoresistivity measurement. R can also detect the explosives in solution with high sensitivity and selectivity by fluorescence spectroscopy.


Assuntos
Benzimidazóis/química , Calixarenos/química , Substâncias Explosivas/análise , Fenóis/química , Espectrometria de Fluorescência , Trinitrotolueno/análise , Compostos de Epóxi/química , Simulação de Dinâmica Molecular , Nanoestruturas/química , Polímeros/química , Propriedades de Superfície , Temperatura
8.
ACS Appl Mater Interfaces ; 4(3): 1434-9, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22332817

RESUMO

We report a unipolar operation in reduced graphene oxide (RGO) field-effect transistors (FETs) via modification of the source/drain (S/D) electrode interfaces with self-assembled monolayers (SAMs) of 5-(4-hydroxyphenyl)-10,15,20-tri-(p-tolyl) zinc(II) porphyrin (Zn(II)TTPOH) molecules. The dipolar Zn(II)TTPOH molecules at the RGO/platinum (Pt) S/D interface results in an increase of the electron injection barrier and a reduction of the hole-injection barrier. Using dipole measurements from Kelvin probe force microscopy and highest occupied molecular orbital-lowest unoccupied molecular orbital (HOMO-LUMO) calculations from cyclic voltammetry, the electron and hole injection barriers were calculated to be 2.2 and 0.11 eV, respectively, indicating a higher barrier for electrons, compared to that of holes. A reduced gate modulation in the electron accumulation regime in RGO devices with SAM shows that unipolar RGO FETs can be attained using a low-cost, solution-processable fabrication technique.

9.
Nanotechnology ; 23(2): 025501, 2012 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-22166842

RESUMO

In this paper, we present experimental results describing enhanced readout of the vibratory response of a doubly clamped zinc oxide (ZnO) nanowire employing a purely electrical actuation and detection scheme. The measured response suggests that the piezoelectric and semiconducting properties of ZnO effectively enhance the motional current for electromechanical transduction. For a doubly clamped ZnO nanowire resonator with radius ~10 nm and length ~1.91 µm, a resonant frequency around 21.4 MHz is observed with a quality factor (Q) of ~358 in vacuum. A comparison with the Q obtained in air (~242) shows that these nano-scale devices may be operated in fluid as viscous damping is less significant at these length scales. Additionally, the suspended nanowire bridges show field effect transistor (FET) characteristics when the underlying silicon substrate is used as a gate electrode or using a lithographically patterned in-plane gate electrode. Moreover, the Young's modulus of ZnO nanowires is extracted from a static bending test performed on a nanowire cantilever using an AFM and the value is compared to that obtained from resonant frequency measurements of electrically addressed clamped­clamped beam nanowire resonators.

10.
Nanotechnology ; 22(29): 295501, 2011 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-21673380

RESUMO

This paper reports an optimized and highly sensitive piezoresistive SU-8 nanocomposite microcantilever sensor and its application for detection of explosives in vapour phase. The optimization has been in improving its electrical, mechanical and transduction characteristics. We have achieved a better dispersion of carbon black (CB) in the SU-8/CB nanocomposite piezoresistor and arrived at an optimal range of 8-9 vol% CB concentration by performing a systematic mechanical and electrical characterization of polymer nanocomposites. Mechanical characterization of SU-8/CB nanocomposite thin films was performed using the nanoindentation technique with an appropriate substrate effect analysis. Piezoresistive microcantilevers having an optimum carbon black concentration were fabricated using a design aimed at surface stress measurements with reduced fabrication process complexity. The optimal range of 8-9 vol% CB concentration has resulted in an improved sensitivity, low device variability and low noise level. The resonant frequency and spring constant of the microcantilever were found to be 22 kHz and 0.4 N m(-1) respectively. The devices exhibited a surface stress sensitivity of 7.6 ppm (mN m(-1))(-1) and the noise characterization results support their suitability for biochemical sensing applications. This paper also reports the ability of the sensor in detecting TNT vapour concentration down to less than six parts per billion with a sensitivity of 1 mV/ppb.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...