Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMJ Glob Health ; 6(9)2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34518203

RESUMO

OBJECTIVES: Kangaroo Mother Care (KMC), prolonged skin-to-skin care of the low birth weight baby with the mother plus exclusive breastfeeding reduces neonatal mortality. Global KMC coverage is low. This study was conducted to develop and evaluate context-adapted implementation models to achieve improved coverage. DESIGN: This study used mixed-methods applying implementation science to develop an adaptable strategy to improve implementation. Formative research informed the initial model which was refined in three iterative cycles. The models included three components: (1) maximising access to KMC-implementing facilities, (2) ensuring KMC initiation and maintenance in facilities and (3) supporting continuation at home postdischarge. PARTICIPANTS: 3804 infants of birth weight under 2000 g who survived the first 3 days, were available in the study area and whose mother resided in the study area. MAIN OUTCOME MEASURES: The primary outcomes were coverage of KMC during the 24 hours prior to discharge and at 7 days postdischarge. RESULTS: Key barriers and solutions were identified for scaling up KMC. The resulting implementation model achieved high population-based coverage. KMC initiation reached 68%-86% of infants in Ethiopian sites and 87% in Indian sites. At discharge, KMC was provided to 68% of infants in Ethiopia and 55% in India. At 7 days postdischarge, KMC was provided to 53%-65% of infants in all sites, except Oromia (38%) and Karnataka (36%). CONCLUSIONS: This study shows how high coverage of KMC can be achieved using context-adapted models based on implementation science. They were supported by government leadership, health workers' conviction that KMC is the standard of care, women's and families' acceptance of KMC, and changes in infrastructure, policy, skills and practice. TRIAL REGISTRATION NUMBERS: ISRCTN12286667; CTRI/2017/07/008988; NCT03098069; NCT03419416; NCT03506698.


Assuntos
Método Canguru , Assistência ao Convalescente , Etiópia , Feminino , Humanos , Índia , Recém-Nascido , Alta do Paciente
2.
J Vasc Access ; 22(3): 353-358, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-32667233

RESUMO

BACKGROUND: Intravenous cannulation is a common procedure and a valuable skill in the neonatal intensive care unit. Standardized procedure and personnel training are needed in the unit to prevent hospital-acquired blood stream infections. Hence, we evaluated the effect of training using a low-fidelity simulation on the improvement of the aseptic non-touch technique during intravenous cannulation and knowledge retention after 6 months. METHODS: The study was conducted in a tertiary care neonatal unit from June 2017 to July 2018. All the staff nurses and junior resident doctors posted in the neonatal intensive care were included in the study. A protocol and checklist score sheet was developed. The score sheet consisted of 23 items with a total score of 46. Participants were expected to obtain a minimum of 80%. A pre-test was conducted initially, followed by a formal training and then a post-test. The NITA newborn venous access mannequin was used to facilitate the training. A re-training for new nurses was conducted after 6 months. Data were analyzed using paired t-test. RESULTS: A total of 29 doctors and nurses were enrolled in the training. The mean pre-test score was 29.93 compared to 42.66 in the post-test scores (mean difference 12.24(95% confidence interval: 9.39-16.05), p < 0.01. The mean scores were higher when the simulation was conducted after 6 months. There was a significant decline in blood stream infection rates from 5.5 to 1.65 per 1000 patient days (p = 0.05). CONCLUSION: Simulation-based training of health care personnel is a good modality to improve aseptic non-touch technique during intravenous cannulation in the neonatal intensive care unit. Simulation-based training also helps in knowledge retention and standardization of training procedures.


Assuntos
Assepsia , Bacteriemia/prevenção & controle , Infecções Relacionadas a Cateter/prevenção & controle , Cateterismo Periférico/efeitos adversos , Infecção Hospitalar/prevenção & controle , Manequins , Treinamento por Simulação , Adulto , Bacteriemia/diagnóstico , Bacteriemia/microbiologia , Infecções Relacionadas a Cateter/diagnóstico , Infecções Relacionadas a Cateter/microbiologia , Lista de Checagem , Competência Clínica , Infecção Hospitalar/diagnóstico , Infecção Hospitalar/microbiologia , Escolaridade , Feminino , Humanos , Masculino , Melhoria de Qualidade , Indicadores de Qualidade em Assistência à Saúde , Retenção Psicológica , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
3.
J Perinatol ; 38(5): 512-516, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29410543

RESUMO

OBJECTIVE: To assess the efficacy of modified Tochen's formula (birth weight + 5 cm) when compared to Tochen's formula for optimum placement of endotracheal tubes (ET) in low birth weight (LBW) neonates. STUDY DESIGN: In the NICU of a tertiary care hospital, LBW babies requiring intubation were randomized to Tochen's formula or modified Tochen's formula. The incidence of inadequate placement and optimum length of ET insertion were estimated. Analysis was done by the Chi square and 't'-tests. RESULTS: Sixty-seven babies were included: 34 in Tochen's group and 33 in modified Tochen's group. Baseline characteristics were similar. Modified Tochen's formula was significantly (p = 0.006) closer to the optimum position when compared to Tochen's formula. The percentages of optimum and adequate placements of the ET tube was higher in the modified Tochen's group, though not statistically significant. CONCLUSION: Modified Tochen's formula in LBW babies may enable more optimum placement of ETs.


Assuntos
Algoritmos , Recém-Nascido de Baixo Peso , Intubação Intratraqueal/instrumentação , Intubação Intratraqueal/métodos , Peso ao Nascer , Feminino , Humanos , Índia , Recém-Nascido , Masculino , Centros de Atenção Terciária
4.
J Trop Pediatr ; 62(4): 263-8, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-26966242

RESUMO

BACKGROUND: Patent ductus arteriosus (PDA) is a significant problem in preterm babies <34 weeks old. Echocardiogram (echo) is the gold standard for diagnosing PDA. Perfusion index (PI) using a pulse oximeter could aid in diagnosing a hemodynamically significant PDA (HsPDA). OBJECTIVE: To evaluate the accuracy of delta-PI (ΔPI; pre-ductal - post-ductal PI) in diagnosing HsPDA in preterm babies <34 weeks old. DESIGN: Prospective analytical cross-sectional (observational) study. METHODS: Preterm infants <34 weeks old (n = 27) were enrolled in the study after parental consent. ΔPI was calculated on Days 1 and 3. Babies are categorized into two groups-HsPDA and no HsPDA based on echo on Day 3. RESULTS: The mean gestational ages were 30.4 ± 1.9 (HsPDA) and 31.7 ± 1.6 weeks (no HsPDA), and birth weights were 1.23 ± 0.32 kg and 1.43 ± 0.34 kg, respectively (p > 0.05). Ten infants had HsPDA. The ΔPI values in Groups A and B differed significantly on Days 1 and 3 (Day 1: 1.06 ± 0.3 vs. 0.54 ± 0.2 and Day 3: 1.11 ± 0.15 vs. 0.57 ± 0.3). The area under the receiver operating characteristic curve was significant for ΔPI on Days 1 and 3. The ΔPI > 0.85 on Day 1 and > 0.95 on Day 3 had a sensitivity and specificity of 80% and 94% and 80% and 88.2%, respectively, for diagnosing HsPDA. CONCLUSION: ΔPI is a useful, simple parameter, which could help in the assessment of PDA in preterm babies.


Assuntos
Permeabilidade do Canal Arterial/diagnóstico por imagem , Permeabilidade do Canal Arterial/fisiopatologia , Recém-Nascido Prematuro/fisiologia , Fluxo Pulsátil/fisiologia , Estudos Transversais , Ecocardiografia , Feminino , Idade Gestacional , Hemodinâmica/fisiologia , Humanos , Recém-Nascido , Masculino , Oximetria , Valor Preditivo dos Testes , Estudos Prospectivos , Curva ROC , Fluxo Sanguíneo Regional/fisiologia , Sensibilidade e Especificidade
5.
J Trop Pediatr ; 60(6): 422-7, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25053125

RESUMO

This prospective cross-sectional study was undertaken to determine the frequency of procedural pain among 101 neonates in the first 14 days of admission to a neonatal intensive care unit (NICU) in South India and to study the perception of health-care professionals (HCP) about newborn procedural pain. The total number of painful procedures was 8.09 ± 5.53 per baby per day and 68.32 ± 64.78 per baby during hospital stay. The most common procedure was heel prick (30%). The HCP were administered a questionnaire to assess their perception of pain for various procedures. Procedures were perceived as more painful by nurses than by doctors. Chest tube placements and lumbar puncture were considered most painful. This study shows that the neonates in the NICU in developing countries experience many painful procedures. The awareness about this intensity of pain should provide a valuable tool in formulating pain-reduction protocols for management in low resource settings.


Assuntos
Atitude do Pessoal de Saúde , Cuidados Críticos/métodos , Unidades de Terapia Intensiva Neonatal/estatística & dados numéricos , Dor/epidemiologia , Percepção , Adulto , Criança , Cuidados Críticos/estatística & dados numéricos , Estudos Transversais , Feminino , Humanos , Índia , Lactente , Recém-Nascido , Recém-Nascido Prematuro , Masculino , Pessoa de Meia-Idade , Dor/etiologia , Dor/prevenção & controle , Manejo da Dor , Medição da Dor/métodos , Estudos Prospectivos , Inquéritos e Questionários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...