Multiplexing has been highlighted to save on costs, increase sample throughput, and maximize on the number of targets that can be sensitively detected within a small sample. With the ongoing SARS-CoV-2 pandemic, different articles have been published highlighting the superiority of droplet digital PCR (ddPCR) over the gold reverse transcription PCR (RT-PCR) in SARS-CoV-2 detection. However, few studies have been reported on developing multiplex ddPCR assays for SARS-CoV-2 detection and their performance. In this study, we developed simplex (1 target), duplex (2 targets), triplex probe mix (3 targets), and fourplex (4 targets) assays based on a two color ddPCR system for SARS-CoV-2 detection. Results showed that the fourplex assay had the similar limits of detection and accuracy to the lower multiplex assays. Analyzing 94 clinical isolates demonstrated that the ddPCR triplex probe mix assay had better sensitivity than the RT-qPCR assay. Additionally, the ddPCR multiplex assay showed that remdesivir could inhibit the growth of SARS-CoV-2 in vitro while another testing drug couldnt. Conclusively, our research shows that developing multiplex ddPCR assays is possible by combing probe mix and amplitude based multiplexing, which will help in developing multiplexed ddPCR assays for different SARS-CoV-2 applications.