Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Prosthet Dent ; 130(2): 266.e1-266.e8, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37422420

RESUMO

STATEMENT OF PROBLEM: Studies on the mechanical, optical, and surface properties of 3-dimensionally (3D) printed denture base materials are scarce, and those available have reported conflicting results. PURPOSE: The purpose of this in vitro study was to compare the mechanical properties, surface roughness, and color stability of 3D-printed and conventional heat-polymerizing denture base materials. MATERIAL AND METHODS: A total of 34 rectangular specimens (64×10×3.3 mm) were fabricated from each of the conventional (SR Triplex Hot; Ivoclar AG) and 3D-printed (Denta base; Asiga) denture base materials. All specimens underwent coffee thermocycling for 5000 cycles, and half in each group (n=17) were evaluated in terms of color parameters, color change (ΔE00), and surface roughness (Ra) before and after coffee thermocycling. The specimens then underwent a 3-point bend test. The remaining specimens in each group (n=17) underwent impact strength and Vickers hardness testing. Data were analyzed by the paired samples, independent samples, and Wilcoxon signed rank tests (α=.05). RESULTS: The color change caused by coffee thermocycling in the 3D-printed group was higher than that in the conventional group (P<.001). Surface roughness significantly increased in both groups after coffee thermocycling (P<.001). The conventional group had higher surface roughness before coffee thermocycling, while the 3D-printed group had higher surface roughness after coffee thermocycling (P<.001). The flexural strength, flexural modulus, and surface hardness in the conventional group were significantly higher than those in the 3D-printed group (P<.001). However, the impact strength of the conventional group was lower than that of the 3D-printed group (P<.001). CONCLUSIONS: The 3D-printed denture base material showed higher impact strength and surface roughness than the conventional heat-polymerizing acrylic resin. However, flexural strength and modulus, surface hardness, and color stability were lower in the 3D-printed group.


Assuntos
Bases de Dentadura , Temperatura Alta , Café , Teste de Materiais , Propriedades de Superfície , Impressão Tridimensional , Cor
2.
Int J Dent ; 2023: 9523683, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36660317

RESUMO

Background: Zirconia has been used as a reliable core material in dental restorations for years; however, its bonding to resin cement is a matter of challenge. Physical, chemical, and combinations of these techniques have been investigated to boost the properties of zirconia surface bonding. The objective of this work was to evaluate the effect of hydroxyapatite coating as a chemical therapy in combination with physical modifications on the microshear bond strength of the resin cement over zirconia. Methods: In the present research, 60 sintered zirconia blocks (4 × 4 × 4 mm) were randomized into four groups of 15, including Al2O3 particle abrasion (group 1), HA coating (group 2), Al2O3 particle abrasion + HA coating (group 3), and Er, Cr: YSGG laser irradiation + HA coating (group 4). The microshear bond strength was determined by bonding the blocks to the resin cement. Results: The bond strengths (mean ± standard deviation) of modified zirconia surfaces were 16.93 ± 4.94 MPa, 16.14 ± 5.4 MPa, 19.4 ± 5.27 MPa, and 16.21 ± 3.7 MPa in groups 1-4, respectively. Test results of the ANOVA test revealed no significant difference regarding the bond strength values of zirconia surfaces to the resin cement between the studied preparation modalities (p > 0.05). Conclusion: Observations from the present study showed that HA coating can be as effective as the air-borne particle abrasion technique in improving bond strength to zirconia surfaces. Moreover, sandblasting by an aluminum oxide or Er, Cr: YSGG laser irradiation prior to HA coating of zirconia showed no significant effect on the reinforcement of bond strength values when compared to HA coating alone. The clinic hydroxyapatite coating alone or in combination with physical treatments improves the bond strength of zirconia to resin cement.

3.
Int J Comput Dent ; 25(2): 181-199, 2022 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-35851356

RESUMO

The integration of modern technologies in removable prosthodontics in terms of complete denture fabrication has revolutionized fabrication procedures, improved outcomes, and led to advancements in denture materials. Numerous publications have described the digital techniques of complete denture fabrication. The steps described in these publications for the proposed digital workflow are diverse. This is suggestive of the flexibility of these modern techniques in terms of their integration with the steps of conventional protocols. Automated technologies have reduced the need for skilled manual work, while particular knowledge and a new skills set are required for both clinicians and dental technicians. Moreover, the effectiveness and efficacy of these modern technologies in complete denture fabrication are yet to be determined. To consolidate the existing literature on digital techniques of complete denture fabrication, this review summarizes the current digital workflows of the clinical and laboratory stages, describes the digital alternatives in each step, and discusses their advantages and limitations.


Assuntos
Desenho Assistido por Computador , Prótese Total , Assistência Odontológica , Humanos , Fluxo de Trabalho
4.
Eur J Dent ; 16(3): 488-499, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35189643

RESUMO

The purpose of this systematic review was to evaluate the clinical and laboratory outcomes of angled screw channel (ASC) restorations and to summarize the influencing factors. An electronic search of the English language literature was performed in four databases and enriched by manual searches. Retrieved studies were screened against the predefined exclusion and inclusion criteria. Eight clinical and seven laboratory studies were eligible for the analysis. The risk of bias for included observational studies was performed using the Newcastle-Ottawa quality assessment scale. Laboratory studies quality assessment method was adapted from previous published systematic reviews. Two clinical studies focused on technical outcomes and the rest reported the biological outcomes of the ASC restorations. Out of the seven laboratory studies, two studies investigated the fracture resistance of ASC restorations, four studies evaluated the reverse torque value of the nonaxially tightened screws, and one study evaluated both variables. The present review revealed that while the performance of ASC restorations is promising in short-term clinical studies, the evidence of their long-term reliability is still lacking. The laboratory studies indicated comparable fracture resistance results of the ASC restorations with the straight screw channel restorations. In addition, factors, such as initial torque value, configuration of the screw driver, screw design, abutment system, and the angulation of screw channel, were shown to influence the screw resistance to loosening.

5.
J Prosthodont ; 30(6): 520-539, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33554361

RESUMO

PURPOSE: To systematically review clinical and laboratory studies that investigated the accuracy of intraoral scanners in recording denture bearing areas. MATERIALS AND METHODS: Electronic and manual searches were conducted to identify all the available clinical and laboratory studies reporting the accuracy of digital impressions for recording denture related soft tissues. After the application of predetermined inclusion and exclusion criteria, the final list of articles was reviewed to meet the objective of this study. RESULTS: The inclusion criteria were met by 18 studies out of which 8 were clinical and the rest were laboratory investigations. The eligible studies assessed the accuracy of intraoral scanners in recording both the denture supporting structures and the peripheral mobile tissues. The accuracy results were different among the various intraoral scanners. Likewise, the effect of several influencing factors, such as artificial markers, scanner head size, scanning strategy, and the operator's experience, were evaluated. CONCLUSION: While the accuracy of intraoral scanners was comparable to the conventional techniques in recording bony structures with attached mucosa, they were not capable of accurately registering the mobile tissues. In addition, factors such as presence of a marker, larger scanner head size and specific scanning techniques appeared to improve the accuracy of the digital impression.


Assuntos
Técnica de Moldagem Odontológica , Modelos Dentários , Desenho Assistido por Computador , Dentaduras , Imageamento Tridimensional
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...