Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Photoacoustics ; 28: 100424, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36386296

RESUMO

Approximately 19 % of breast cancer patients undergoing breast conserving surgery (BCS) must return for a secondary surgery due to incomplete tumour removal. Our previous work demonstrated that the lower lipid content, characteristic of tumour tissue, was observed as regions of hypo-intense photoacoustic (PA) contrast. The goal of this work was to evaluate feasibility of a low-frequency, hand-held PA imaging probe for surgical margin assessment based on lipid content differences. Here, we describe (i) the design of a prototype hand-held PA imaging probe, (ii) the effect of limited-bandwidth on image contrast, (iii) accuracy towards hypo-intense contrast detection, (iv) the limited-view characteristics of the single sensor design, and (iv) early imaging results of an ex-vivo breast cancer specimen. The probe incorporates a single polyvinylidene fluoride acoustic sensor, a 1-to-4 optical fibre bundle and a polycarbonate axicon lens for light delivery. Imaging results on phantoms designed to mimic positive margins demonstrated the ability to detect gaps in optical absorption as small as 1 mm in width. Compared to images from a near full-view PAI system, the hand-held PAI probe had higher signal to noise ratio but suffered from negativity image artifacts. Lumpectomy specimen imaging showed that strong signals can be obtained from the fatty tissue. Taken together, the results show this imaging approach with a hand-held probe has potential for detection of residual breast cancer tissue during BCS; however, more work is needed to reduce the size of the probe to fit within the surgical cavity.

2.
Photoacoustics ; 28: 100404, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36185542

RESUMO

Photoacoustic tomography (PAT) provides high resolution optical images of tissue at depths of up to several centimetres. This modality has been of interest to researchers for at least 30 years and is still the subject of intensive research. However, PAT researchers lack access to a comprehensive open-source graphical simulation and reconstruction software package. In this article, we introduce PATLAB, an open-source MATLAB-based graphical software package that can perform both PAT simulation and image reconstruction. PATLAB is simple to use yet is capable of complex PAT data processing tasks and offers advanced users a framework to build and test new methods.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...