Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 157
Filtrar
1.
Phys Imaging Radiat Oncol ; 31: 100598, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38993288

RESUMO

Background & purpose: Magnetic resonance imaging (MRI) is increasingly used in treatment preparation of ocular proton therapy, but its spatial accuracy might be limited by geometric distortions due to susceptibility artefacts. A correct geometry of the MR images is paramount since it defines where the dose will be delivered. In this study, we assessed the geometrical accuracy of ocular MRI. Materials & methods: A dedicated ocular 3 T MRI protocol, with localized shimming and increased gradients, was compared to computed tomography (CT) and X-ray images in a phantom and in 15 uveal melanoma patients. The MRI protocol contained three-dimensional T2-weighted and T1-weighted sequences with an isotropic reconstruction resolution of 0.3-0.4 mm. Tantalum clips were identified by three observers and clip-clip distances were compared between T2-weighted and T1-weighted MRI, CT and X-ray images for the phantom and between MRI and X-ray images for the patients. Results: Interobserver variability was below 0.35 mm for the phantom and 0.30(T1)/0.61(T2) mm in patients. Mean absolute differences between MRI and reference were below 0.27 ± 0.16 mm and 0.32 ± 0.23 mm for the phantom and in patients, respectively. In patients, clip-clip distances were slightly larger on MRI than on X-ray images (mean difference T1: 0.11 ± 0.38 mm, T2: 0.10 ± 0.44 mm). Differences did not increase at larger distances and did not correlate to interobserver variability. Conclusions: A dedicated ocular MRI protocol can produce images of the eye with a geometrical accuracy below half the MRI acquisition voxel (<0.4 mm). Therefore, these images can be used for ocular proton therapy planning, both in the current model-based workflow and in proposed three-dimensional MR-based workflows.

2.
Radiother Oncol ; 196: 110281, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38636708

RESUMO

BACKGROUND AND PURPOSE: This multicenter randomized phase III trial evaluated whether locoregional control of patients with LAHNSCC could be improved by fluorodeoxyglucose-positron emission tomography (FDG-PET)-guided dose-escalation while minimizing the risk of increasing toxicity using a dose-redistribution and scheduled adaptation strategy. MATERIALS AND METHODS: Patients with T3-4-N0-3-M0 LAHNSCC were randomly assigned (1:1) to either receive a dose distribution ranging from 64-84 Gy/35 fractions with adaptation at the 10thfraction (rRT) or conventional 70 Gy/35 fractions (cRT). Both arms received concurrent three-cycle 100 mg/m2cisplatin. Primary endpoints were 2-year locoregional control (LRC) and toxicity. Primary analysis was based on the intention-to-treat principle. RESULTS: Due to slow accrual, the study was prematurely closed (at 84 %) after randomizing 221 eligible patients between 2012 and 2019 to receive rRT (N = 109) or cRT (N = 112). The 2-year LRC estimate difference of 81 % (95 %CI 74-89 %) vs. 74 % (66-83 %) in the rRT and cRT arm, respectively, was not found statistically significant (HR 0.75, 95 %CI 0.43-1.31,P=.31). Toxicity prevalence and incidence rates were similar between trial arms, with exception for a significant increased grade ≥ 3 pharyngolaryngeal stenoses incidence rate in the rRT arm (0 versus 4 %,P=.05). In post-hoc subgroup analyses, rRT improved LRC for patients with N0-1 disease (HR 0.21, 95 %CI 0.05-0.93) and oropharyngeal cancer (0.31, 0.10-0.95), regardless of HPV. CONCLUSION: Adaptive and dose redistributed radiotherapy enabled dose-escalation with similar toxicity rates compared to conventional radiotherapy. While FDG-PET-guided dose-escalation did overall not lead to significant tumor control or survival improvements, post-hoc results showed improved locoregional control for patients with N0-1 disease or oropharyngeal cancer treated with rRT.


Assuntos
Fluordesoxiglucose F18 , Neoplasias de Cabeça e Pescoço , Carcinoma de Células Escamosas de Cabeça e Pescoço , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Carcinoma de Células Escamosas de Cabeça e Pescoço/radioterapia , Carcinoma de Células Escamosas de Cabeça e Pescoço/diagnóstico por imagem , Carcinoma de Células Escamosas de Cabeça e Pescoço/terapia , Idoso , Neoplasias de Cabeça e Pescoço/radioterapia , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos , Radioterapia Guiada por Imagem/métodos , Adulto , Dosagem Radioterapêutica , Fracionamento da Dose de Radiação , Quimiorradioterapia/métodos , Quimiorradioterapia/efeitos adversos
3.
Int J Radiat Oncol Biol Phys ; 119(3): 968-977, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38284961

RESUMO

PURPOSE: Our purpose was to compare robust intensity modulated proton therapy (IMPT) plans, automatically generated with wish-list-based multicriterial optimization as implemented in Erasmus-iCycle, with manually created robust clinical IMPT plans for patients with head and neck cancer. METHODS AND MATERIALS: Thirty-three patients with head and neck cancer were retrospectively included. All patients were previously treated with a manually created IMPT plan with 7000 cGy dose prescription to the primary tumor (clinical target volume [CTV]7000) and 5425 cGy dose prescription to the bilateral elective volumes (CTV5425). Plans had a 4-beam field configuration and were generated with scenario-based robust optimization (21 scenarios, 3-mm setup error, and ±3% density uncertainty for the CTVs). Three clinical plans were used to configure the Erasmus-iCycle wish-list for automated generation of robust IMPT plans for the other 30 included patients, in line with clinical planning requirements. Automatically and manually generated IMPT plans were compared for (robust) target coverage, organ-at-risk (OAR) doses, and normal tissue complication probabilities (NTCP). No manual fine-tuning of automatically generated plans was performed. RESULTS: For all automatically generated plans, voxel-wise minimum D98% values for the CTVs were within clinical constraints and similar to manual plans. All investigated OAR parameters were favorable in the automatically generated plans (all P < .001). Median reductions in mean dose to OARs went up to 667 cGy for the inferior pharyngeal constrictor muscle, and median reductions in D0.03cm3 in serial OARs ranged up to 1795 cGy for the spinal cord surface. The observed lower mean dose in parallel OARs resulted in statistically significant lower NTCP for xerostomia (grade ≥2: 34.4% vs 38.0%; grade ≥3: 9.0% vs 10.2%) and dysphagia (grade ≥2: 11.8% vs 15.0%; grade ≥3: 1.8% vs 2.8%). CONCLUSIONS: Erasmus-iCycle was able to produce IMPT dose distributions fully automatically with similar (robust) target coverage and improved OAR doses and NTCPs compared with clinical manual planning, with negligible hands-on planning workload.


Assuntos
Neoplasias de Cabeça e Pescoço , Órgãos em Risco , Terapia com Prótons , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Órgãos em Risco/diagnóstico por imagem , Órgãos em Risco/efeitos da radiação , Radioterapia de Intensidade Modulada/métodos , Neoplasias de Cabeça e Pescoço/radioterapia , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Estudos Retrospectivos , Terapia com Prótons/métodos , Automação , Masculino , Erros de Configuração em Radioterapia/prevenção & controle
4.
Invest Ophthalmol Vis Sci ; 65(1): 43, 2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38271188

RESUMO

Purpose: Although fundus photography is extensively used in ophthalmology, refraction prevents accurate distance measurement on fundus images, as the resulting scaling differs between subjects due to varying ocular anatomy. We propose a PARaxial Optical fundus Scaling (PAROS) method to correct for this variation using commonly available clinical data. Methods: The complete optics of the eye and fundus camera were modeled using ray transfer matrix formalism to obtain fundus image magnification. The subject's ocular geometry was personalized using biometry, spherical equivalent of refraction (RSE), keratometry, and/or corneal topography data. The PAROS method was validated using 41 different eye phantoms and subsequently evaluated in 44 healthy phakic subjects (of whom 11 had phakic intraocular lenses [pIOLs]), 29 pseudophakic subjects, and 21 patients with uveal melanoma. Results: Validation of the PAROS method showed small differences between model and actual image magnification (maximum 3.3%). Relative to the average eye, large differences in fundus magnification were observed, ranging from 0.79 to 1.48. Magnification was strongly inversely related to RSE (R2 = 0.67). In phakic subjects, magnification was directly proportional to axial length (R2 = 0.34). The inverse relation was seen in pIOL (R2 = 0.79) and pseudophakic (R2 = 0.12) subjects. RSE was a strong contributor to magnification differences (1%-83%). As this effect is not considered in the commonly used Bennett-Littmann method, statistically significant differences up to 40% (mean absolute 9%) were observed compared to the PAROS method (P < 0.001). Conclusions: The significant differences in fundus image scaling observed among subjects can be accurately accounted for with the PAROS method, enabling more accurate quantitative assessment of fundus photography.


Assuntos
Técnicas de Diagnóstico Oftalmológico , Refração Ocular , Humanos , Oftalmoscopia , Fundo de Olho , Córnea
5.
Cancers (Basel) ; 15(22)2023 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-38001679

RESUMO

BACKGROUND: Uveal melanoma (UM) is a rare intraocular tumor with a dismal prognosis once metastasized. This study provides a nationwide overview and time trends of patients diagnosed with primary UM in the Netherlands between 1989 and 2019. METHODS: A retrospective population-based cohort study based on patients with primary UM from the database of the Netherlands Cancer Registry (NCR), linked with the national population registry Statistics Netherlands on inhabitants' cause of death. Two time periods (1989-2004, 2005-2019) were compared with descriptive statistics. Kaplan-Meier and (multivariate) Cox proportional hazard models were used to assess changes over time for overall survival (OS) and cancer-specific survival (CSS). RESULTS: In total, 5036 patients were analyzed with a median age of 64.0 years at the time of diagnosis. The number of patients increased over time. In the first (1989-2004) and second (2005-2019) period, 32% versus 54% of the patients received radiotherapy (p < 0.001). The median FU time was 13.4 years. The median OS of the first and second periods was 9.5 (95% CI 8.7-10.3) versus 11.3 years (95% CI 10.3-12.3; p < 0.001). The median CSS was 30.0 years (95% CI NA) in the first period and not reached in the second period (p = 0.008). In multivariate analysis (MVA), female gender (HR 0.85; 95% CI 0.79-0.92, p < 0.001) and radiotherapy treatment (HR 0.73; 95% CI 0.64-0.83, p < 0.001) were associated with better OS. Radiotherapy treatment (HR 0.74; 95% CI 0.61-0.90, p = 0.002) was also associated with better CSS. The period of diagnosis was not associated with OS or CSS. CONCLUSIONS: In this study of patients with primary UM, there was a shift to the diagnosis of smaller tumors, possibly due to stage migration. There was also an increase in eye-preserving treatments over time. OS and CSS were modestly improved in the second time period; however, the time period was not associated with OS or CSS in multivariate analyses.

6.
Front Cardiovasc Med ; 10: 1267800, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37799779

RESUMO

Background: Stereotactic arrhythmia radioablation (STAR) is a potential new therapy for patients with refractory ventricular tachycardia (VT). The arrhythmogenic substrate (target) is synthesized from clinical and electro-anatomical information. This study was designed to evaluate the baseline interobserver variability in target delineation for STAR. Methods: Delineation software designed for research purposes was used. The study was split into three phases. Firstly, electrophysiologists delineated a well-defined structure in three patients (spinal canal). Secondly, observers delineated the VT-target in three patients based on case descriptions. To evaluate baseline performance, a basic workflow approach was used, no advanced techniques were allowed. Thirdly, observers delineated three predefined segments from the 17-segment model. Interobserver variability was evaluated by assessing volumes, variation in distance to the median volume expressed by the root-mean-square of the standard deviation (RMS-SD) over the target volume, and the Dice-coefficient. Results: Ten electrophysiologists completed the study. For the first phase interobserver variability was low as indicated by low variation in distance to the median volume (RMS-SD range: 0.02-0.02 cm) and high Dice-coefficients (mean: 0.97 ± 0.01). In the second phase distance to the median volume was large (RMS-SD range: 0.52-1.02 cm) and the Dice-coefficients low (mean: 0.40 ± 0.15). In the third phase, similar results were observed (RMS-SD range: 0.51-1.55 cm, Dice-coefficient mean: 0.31 ± 0.21). Conclusions: Interobserver variability is high for manual delineation of the VT-target and ventricular segments. This evaluation of the baseline observer variation shows that there is a need for methods and tools to improve variability and allows for future comparison of interventions aiming to reduce observer variation, for STAR but possibly also for catheter ablation.

7.
Neuroradiology ; 65(8): 1271-1285, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37249621

RESUMO

PURPOSE: MRI is increasingly used in the diagnosis and therapy planning of uveal melanoma (UM). In this prospective cohort study, we assessed the radiological characteristics, in terms of anatomical and functional imaging, of UM after ruthenium-106 plaque brachytherapy or proton beam therapy (PBT) and compared them to conventional ultrasound. METHODS: Twenty-six UM patients were evaluated before and 3, 6 and 12 months after brachytherapy (n = 13) or PBT (n = 13). Tumour prominences were compared between ultrasound and MRI. On diffusion-weighted imaging, the apparent diffusion value (ADC), and on perfusion-weighted imaging (PWI), the time-intensity curves (TIC), relative peak intensity and outflow percentages were determined. Values were compared between treatments and with baseline. RESULTS: Pre-treatment prominences were comparable between MRI and ultrasound (mean absolute difference 0.51 mm, p = 0.46), but larger differences were observed post-treatment (e.g. 3 months: 0.9 mm (p = 0.02)). Pre-treatment PWI metrics were comparable between treatment groups. After treatment, brachytherapy patients showed favourable changes on PWI (e.g. 67% outflow reduction at 3 months, p < 0.01). After PBT, significant perfusion changes were observed at a later timepoint (e.g. 38% outflow reduction at 6 months, p = 0.01). No consistent ADC changes were observed after either treatment, e.g. a 0.11 × 10-3mm2/s increase 12 months after treatment (p = 0.15). CONCLUSION: MR-based follow-up is valuable for PBT-treated patients as favourable perfusion changes, including a reduction in outflow, can be detected before a reduction in size is apparent on ultrasound. For brachytherapy, a follow-up MRI is of less value as already 3 months post-treatment a significant size reduction can be measured on ultrasound.


Assuntos
Braquiterapia , Terapia com Prótons , Neoplasias Uveais , Humanos , Seguimentos , Estudos Prospectivos , Terapia com Prótons/métodos , Braquiterapia/métodos , Neoplasias Uveais/diagnóstico por imagem , Neoplasias Uveais/radioterapia , Imageamento por Ressonância Magnética , Estudos Retrospectivos
8.
Cancers (Basel) ; 15(7)2023 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-37046660

RESUMO

BACKGROUND: Patients with brain, head, and neck tumors experience a decline in their quality of life due to radiation retinopathy and optic neuropathy. Little is known about the dose-response relationship and patient characteristics. We aimed to systematically review the prevalence of radiation retinopathy and optic neuropathy. METHOD: The primary outcome was the pooled prevalence of radiation retinopathy and optic neuropathy. The secondary outcome included the effect of the total radiation dose prescribed for the tumor according to the patient's characteristics. Furthermore, we aimed to evaluate the radiation dose parameters for organs at risk of radiation retinopathy and optic neuropathy. RESULTS: The pooled prevalence was 3.8%. No retinopathy was reported for the tumor's prescribed dose of <50 Gy. Optic neuropathy was more prevalent for a prescribed dose of >50 Gy than <50 Gy. We observed a higher prevalence rate for retinopathy (6.0%) than optic neuropathy (2.0%). Insufficient data on the dose for organs at risk were reported. CONCLUSION: The prevalence of radiation retinopathy was higher compared to optic neuropathy. This review emphasizes the need for future studies considering retinopathy and optic neuropathy as primary objective parameters.

9.
Clin Transl Radiat Oncol ; 39: 100598, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36860581

RESUMO

Background: Intensity Modulated Proton Therapy (IMPT) in head and neck cancer (HNC) is susceptible to anatomical changes and patient set-up inaccuracies during the radiotherapy course, which can cause discrepancies between planned and delivered dose. The discrepancies can be counteracted by adaptive replanning strategies. This article reviews the observed dosimetric impact of adaptive proton therapy (APT) and the timing to perform a plan adaptation in IMPT in HNC. Methods: A literature search of articles published in PubMed/MEDLINE, EMBASE and Web of Science from January 2010 to March 2022 was performed. Among a total of 59 records assessed for possible eligibility, ten articles were included in this review. Results: Included studies reported on target coverage deterioration in IMPT plans during the RT course, which was recovered with the application of an APT approach. All APT plans showed an average improved target coverage for the high- and low-dose targets as compared to the accumulated dose on the planned plans. Dose improvements up to 2.5 Gy (3.5 %) and up to 4.0 Gy (7.1 %) in the D98 of the high- and low dose targets were observed with APT. Doses to the organs at risk (OARs) remained equal or decreased slightly after APT was applied. In the included studies, APT was largely performed once, which resulted in the largest target coverage improvement, but eventual additional APT improved the target coverage further. There is no data showing what is the most appropriate timing for APT. Conclusion: APT during IMPT for HNC patients improves target coverage. The largest improvement in target coverage was found with a single adaptive intervention, and an eventual second or more frequent APT application improved the target coverage further. Doses to the OARs remained equal or decreased slightly after applying APT. The most optimal timing for APT is yet to be determined.

10.
Europace ; 25(3): 1015-1024, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36746553

RESUMO

AIMS: Stereotactic arrhythmia radiotherapy (STAR) is suggested as potentially effective and safe treatment for patients with therapy-refractory ventricular tachycardia (VT). However, the current prospective knowledge base and experience with STAR is limited. In this study we aimed to prospectively evaluate the efficacy and safety of STAR. METHODS AND RESULTS: The StereoTactic Arrhythmia Radiotherapy in the Netherlands no.1 was a pre-post intervention study to prospectively evaluate efficacy and safety of STAR. In patients with therapy-refractory VT, the pro-arrhythmic region was treated with a 25 Gy single radiotherapy fraction. The main efficacy measure was a reduction in the number of treated VT-episodes by ≥50%, comparing the 12 months before and after treatment (or end of follow-up, excluding a 6-week blanking period). The study was deemed positive when ≥50% of patients would meet this criterion. Safety evaluation included left ventricular ejection fraction, pulmonary function, and adverse events. Six male patients with an ischaemic cardiomyopathy were enrolled, and median age was 73 years (range 54-83). Median left ventricular ejection fraction was 38% (range 24-52). The median planning target volume was 187 mL (range 93-372). Four (67%) patients completed the 12-month follow-up, and two patients died (not STAR related) during follow-up. The main efficacy measure of ≥50% reduction in treated VT-episodes at the end of follow-up was achieved in four patients (67%). The median number of treated VT-episodes was reduced by 87%. No reduction in left ventricular ejection fraction or pulmonary function was observed. No treatment related serious adverse events occurred. CONCLUSIONS: STAR resulted in a ≥ 50% reduction in treated VT-episodes in 4/6 (67%) patients. No reduction in cardiac and pulmonary function nor treatment-related serious adverse events were observed during follow-up. CLINICAL TRIAL REGISTRATION: Netherlands Trial Register-NL7510.


Assuntos
Radiocirurgia , Taquicardia Ventricular , Idoso , Idoso de 80 Anos ou mais , Humanos , Masculino , Pessoa de Meia-Idade , Coração , Radiocirurgia/efeitos adversos , Radiocirurgia/métodos , Volume Sistólico , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/radioterapia , Resultado do Tratamento , Função Ventricular Esquerda
11.
Adv Radiat Oncol ; 8(3): 101149, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36691449

RESUMO

Purpose: Several efforts are being undertaken toward MRI-based treatment planning for ocular proton therapy for uveal melanoma (UM). The interobserver variability of the gross target volume (GTV) on magnetic resonance imaging (MRI) is one of the important parameters to design safety margins for a reliable treatment. Therefore, this study assessed the interobserver variation in GTV delineation of UM on MRI. Methods and Materials: Six observers delineated the GTV in 10 different patients using the Big Brother contouring software. Patients were scanned at 3T MRI with a surface coil, and tumors were delineated separately on contrast enhanced 3DT1 (T1gd) and 3DT2-weighted scans with an isotropic acquisition resolution of 0.8 mm. Volume difference and overall local variation (median standard deviation of the distance between the delineated contours and the median contour) were analyzed for each GTV. Additionally, the local variation was analyzed for 4 interfaces: sclera, vitreous, retinal detachment, and tumor-choroid interface. Results: The average GTV was significantly larger on T1gd (0.57cm3) compared with T2 (0.51cm3, P = .01). A not significant higher interobserver variation was found on T1gd (0.41 mm) compared with T2 (0.35 mm). The largest variations were found at the tumor-choroid interface due to peritumoral enhancement (T1gd, 0.62 mm; T2, 0.52 mm). As a result, a larger part of this tumor-choroid interface appeared to be included on T1gd-based GTVs compared with T2, explaining the smaller volumes on T2. Conclusions: The interobserver variation of 0.4 mm on MRI are low with respect to the voxel size of 0.8 mm, enabling small treatment margins. We recommend delineation based on the T1gd-weighted scans, as choroidal tumor extensions might be missed.

12.
Ophthalmol Retina ; 7(2): 178-188, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35840053

RESUMO

OBJECTIVE: Conventionally, ocular proton therapy (PT) is planned using measurements obtained by an ophthalmologist using ultrasound, fundoscopy, biometry, and intraoperative assessments. Owing to the recent advances in magnetic resonance imaging (MRI) of uveal melanoma (UM), it is possible to acquire high-resolution 3-dimensional images of the eye, providing the opportunity to incorporate MRI in ocular PT planning. In this study, we described how these measurements can be obtained using MRI, compared the MRI-based measurements with conventional ophthalmic measurements, and identified potential pitfalls for both modalities. DESIGN: Cross-sectional study. SUBJECTS: Data from 23 consecutive patients with UM treated with PT were retrospectively evaluated. METHODS: Magnetic resonance imaging-based measurements of axial length, tumor height and basal diameter, and marker-tumor distances were compared with the conventional ophthalmic measurements, and discrepancies were evaluated in a multidisciplinary setting. MAIN OUTCOME MEASURES: Tumor prominence and basal diameters on MRI and ultrasound, axial length on MRI and biometry, tumor-marker distances on MRI and measured intraoperatively. RESULTS: The mean absolute differences of the tumor height and basal diameter measurements between ultrasound and MRI were 0.57 mm and 1.44 mm, respectively. Larger absolute differences in height and basal diameter were observed when the full tumor extent was not visible on ultrasound (0.92 mm and 1.67 mm, respectively) compared with when the full tumor extent was visible (0.44 mm and 1.15 mm, respectively). When the full tumor was not visible on ultrasound, MRI was considered more reliable. Tumor-marker distances measured using MRI and intraoperative techniques differed < 1 mm in 55% of the markers. For anteriorly located and mushroom-shaped tumors (25% of the markers), MRI provided more accurate measurements. In flat UM (15% of the markers), however, it was difficult to delineate the tumor on MRI. The mean absolute difference in axial length between optical biometry and MRI was 0.50 mm. The presence of the tumor was found to influence optical biometry in 15 of 22 patients; the remaining patients showed a better agreement (0.30 mm). Magnetic resonance imaging-based biometry was considered more reliable in patients with UM. CONCLUSIONS: Magnetic resonance imaging allowed for the 3-dimensional assessment of the tumor and surrounding tissue. In specific patients, it provided a more reliable measurement of axial length, tumor dimensions, and marker-tumor distances and could contribute to a more accurate treatment planning. Nevertheless, a combined evaluation remains advised, especially for flat UM.


Assuntos
Terapia com Prótons , Humanos , Estudos Transversais , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos
13.
Phys Imaging Radiat Oncol ; 24: 102-110, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36386446

RESUMO

Background and Purpose: Three-dimensional (3D) Magnetic Resonance Imaging (MRI) is increasingly used to complement conventional two-dimensional ultrasound in the assessment of tumour dimension measurement of uveal melanoma. However, the lack of definitions of the 3D measurements of these tumour dimensions hinders further adaptation of MRI in ocular radiotherapy planning. In this study, we composed 3D MR-based definitions of tumour prominence and basal diameter and compared them to conventional ultrasound. Materials and methods: Tumours were delineated on 3DT2 and contrast-enhanced 3DT1 (T1gd) MRI for 25 patients. 3D definitions of tumour prominence and diameter were composed and evaluated automatically on the T1gd and T2 contours. Automatic T1gd measurements were compared to manual MRI measurements, to automatic T2 measurements and to manual ultrasound measurements. Results: Prominence measurements were similar for all modalities (median absolute difference 0.3 mm). Automatic T1gd diameter measurements were generally larger than manual MRI, automatic T2 and manual ultrasound measurements (median absolute differences of 0.5, 1.6 and 1.1 mm respectively), mainly due to difficulty defining the axis of the largest diameter. Largest differences between ultrasound and MRI for both prominence and diameter were found in anteriorly located tumours (up to 1.6 and 4.5 mm respectively), for which the tumour extent could not entirely be visualized with ultrasound. Conclusions: The proposed 3D definitions for tumour prominence and diameter agreed well with ultrasound measurements for tumours for which the extent was visible on ultrasound. 3D MRI measurements generally provided larger diameter measurements than ultrasound. In anteriorly located tumours, the MRI measurements were considered more accurate than conventional ultrasound.

14.
Artigo em Inglês | MEDLINE | ID: mdl-36247369

RESUMO

Introduction: During the COVID-19 pandemic the ESTRO School who provides international non-profit postgraduate education in Radiation Oncology and related disciplines, including Medical Physics and Radiation Technology, had to close down all live educational activities and turn online, although having only limited experience. The paper describes the experience, discusses the limitations and benefits of online education and suggests directions for the future. Materials and methods: Data about format and feedback from attendees and faculty members from the course activities held in 2019, 2020 and 2021 were made available from the ESTRO School. Results: In 2020, all but two out of thirty live courses that happened before the lockdown were canceled. Among the 18 courses scheduled in the second half of the year, seven went online with a short notice. Each course planned their activities quite differently, from compressed courses with consecutive full days online program to courses over several weeks with a few hours online a week. Both numbers of participants and different nationalities were higher than live courses in 2019 for the seven courses happening online, and courses were well evaluated by participants and faculties. Roughly-one-third of participants would prefer online courses in the future. Discussion: Although online education was well received by the majority, pros and cons exist and especially the personal discussions and networking were missed. Online education and live education are not comparable but can complement each other. Careful balancing these activities in the future is important and strategies for online andragogy are needed.

16.
Cancers (Basel) ; 14(7)2022 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-35406443

RESUMO

Patient-reported outcome measures (PROMs) are advocated for the monitoring of toxicity after radiotherapy. However, studies comparing physician- and patient-reported toxicity show low concordance. In this study, we compared physician- and patient-reported toxicity in long-term prostate cancer survivors after radiotherapy, and we determined the correlation with a presumable risk factor for late toxicity: γ-H2AX foci decay ratio (FDR). Patients formerly included in a prospective study were invited to participate in this new study, comprising one questionnaire and one call with a trial physician assistant. Concordance was calculated for seven symptoms. Gamma-H2AX FDRs were determined in ex vivo irradiated lymphocytes in a previous analysis. Associations between FDR and long-term prevalence of toxicity were assessed using univariable logistic regression analyses. The 101 participants had a median follow-up period of 9 years. Outcomes were discordant in 71% of symptomatic patients; in 21%, the physician-assessed toxicity (using CTCAE) was higher, and, in 50%, the patients reported higher toxicity. We did not find a correlation between presence of toxicity at long-term follow-up and FDR. In conclusion, patients assigned greater severity to symptoms than the trial physician assistant did. Consideration of both perspectives may be warranted to provide the best care.

17.
Radiother Oncol ; 167: 149-157, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34973278

RESUMO

PURPOSE: To investigate the impact of hyperthermia thermal dose (TD) on locoregional control (LRC), overall survival (OS) and toxicity in locoregional recurrent breast cancer patients treated with postoperative re-irradiation and hyperthermia. METHODS: In this retrospective study, 112 women with resected locoregional recurrent breast cancer treated in 2010-2017 with postoperative re-irradiation 8frx4Gy (n = 34) or 23frx2Gy (n = 78), combined with 4-5 weekly hyperthermia sessions guided by invasive thermometry, were subdivided into 'low' (n = 56) and 'high' TD (n = 56) groups by the best session with highest median cumulative equivalent minutes at 43 °C (Best CEM43T50) < 7.2 min and ≥7.2 min, respectively. Actuarial LRC, OS and late toxicity incidence were analyzed. Backward multivariable Cox regression and inverse probability weighting (IPW) analysis were performed. RESULTS: TD subgroups showed no significant differences in patient/treatment characteristics. Median follow-up was 43 months (range 1-107 months). High vs. low TD was associated with LRC (p = 0.0013), but not with OS (p = 0.29) or late toxicity (p = 0.58). Three-year LRC was 74.0% vs. 92.3% in the low and high TD group, respectively (p = 0.008). After three years, 25.0% and 0.9% of the patients had late toxicity grade 3 and 4, respectively. Multivariable analysis showed that distant metastasis (HR 17.6; 95%CI 5.2-60.2), lymph node involvement (HR 2.9; 95%CI 1.2-7.2), recurrence site (chest wall vs. breast; HR 4.6; 95%CI 1.8-11.6) and TD (low vs. high; HR 4.1; 95%CI 1.4-11.5) were associated with LRC. TD was associated with LRC in IPW analysis (p = 0.0018). CONCLUSIONS: High thermal dose (best CEM43T50 ≥ 7.2 min) was associated with significantly higher LRC for patients with locoregional recurrent breast cancer treated with postoperative re-irradiation and hyperthermia, without augmenting toxicity.


Assuntos
Neoplasias da Mama , Hipertermia Induzida , Reirradiação , Neoplasias da Mama/radioterapia , Neoplasias da Mama/cirurgia , Terapia Combinada , Feminino , Humanos , Hipertermia Induzida/efeitos adversos , Masculino , Recidiva Local de Neoplasia/patologia , Reirradiação/efeitos adversos , Estudos Retrospectivos , Temperatura
18.
Int J Radiat Oncol Biol Phys ; 112(1): 212-221, 2022 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-34419566

RESUMO

PURPOSE: Late radiation toxicity is a major dose-limiting factor in curative cancer radiation therapy. Previous studies identified several risk factors for late radiation toxicity, including both dose-volume factors and genetic predisposition. Herein, we investigated the contribution of genetic predisposition, particularly compared with dose-volume factors, to the risk of late radiation toxicity in patients treated with highly conformal radiation therapy. METHODS AND MATERIALS: We included 179 patients with prostate cancer who underwent treatment with curative external beam radiation therapy between 2009 and 2013. Toxicity was graded according to the Common Terminology Criteria for Adverse Events version 4.0. Transcriptional responsiveness of homologous recombination repair genes and γ-H2AX foci decay ratios (FDRs) were determined in ex vivo irradiated lymphocytes in a previous analysis. Dose-volume parameters were retrieved by delineating the organs at risk (OARs) on CT planning images. Associations between risk factors and grade ≥2 urinary and bowel late radiation toxicities were assessed using univariable and multivariable logistic regression analyses. The analyses were performed using the highest toxicity grade recorded during the follow-up per patient. RESULTS: The median follow-up period was 31 months. One hundred and one patients (56%) developed grade ≥2 late radiation toxicity. Cumulative rates for urinary and bowel grade ≥2 late toxicities were 46% and 17%, respectively. In the multivariable analysis, factors significantly associated with grade ≥2 late toxicity were transurethral resection of the prostate (P = .013), γ-H2AX FDR <3.41 (P = .008), and rectum V70 >11.52% (P = .017). CONCLUSIONS: Our results suggest that impaired DNA double-strand break repair in lymphocytes, as quantified by γ-H2AX FDR, is the most critical determining factor of late radiation toxicity. The limited influence of dose-volume parameters could be due to the use of increasingly conformal techniques, leading to improved dose-volume parameters of the organs at risk.


Assuntos
Neoplasias da Próstata , Lesões por Radiação , Radioterapia Conformacional , Ressecção Transuretral da Próstata , Humanos , Masculino , Estudos Prospectivos , Neoplasias da Próstata/genética , Lesões por Radiação/etiologia , Dosagem Radioterapêutica , Radioterapia Conformacional/efeitos adversos , Radioterapia Conformacional/métodos , Reto , Ressecção Transuretral da Próstata/efeitos adversos
19.
Cancers (Basel) ; 13(24)2021 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-34944862

RESUMO

OBJECTIVE: To assess oncological and ophthalmological outcomes after international referral of uveal melanoma patients for proton therapy. MATERIALS AND METHODS: This is a retrospective study among Dutch uveal melanoma patients who were treated in Switzerland with 60.0 CGE proton therapy (in 4 fractions) from 1987 to 2019. All patients were ineligible for brachytherapy due to tumour size and/or proximity to the optic nerve. Time-to-event analyses were performed using Kaplan-Meier's methodology and Cox proportional hazards models. RESULTS: There were 103 patients (104 eyes) with a median largest tumour diameter of 19 mm (range 6-26 mm). Tumours were localised centrally (11%), mid-peripherally (65%) or peripherally (34%). Median follow-up was 7 years. Five-year local control, distant metastasis-free survival and eye preservation rates were 94%, 70% and 81% respectively. At five years, severe, moderate and mild visual impairment was observed in respectively 79%, 4% and 6% of the patients. Larger tumour volumes and more central tumour localisation were associated with severe visual impairment. After correction for these factors, dose to the macula, optic disc and retina, but not optic nerve was significantly associated with severe visual impairment. CONCLUSION: International referral for proton therapy yielded good tumour control and eye preservation rates, but risk of distant metastasis and severe visual impairment were substantial, possibly due to the selection of advanced tumour stages and/or central localisation. Dose to the macula may be more relevant than dose to the optic nerve for preservation of visual acuity, which is relevant for the treatment planning of proton therapy.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...