1.
Clin Exp Obstet Gynecol ; 42(6): 827-32, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26753498

RESUMO

Uterine leiomyomas are the most common benign gynecological tumors affecting 20-30% of women in reproductive age. Despite their benignity, in some cases several symptoms may require surgical intervention. Submucosal leiomyomas are less frequent (5-10%), but are usually symptomatic. Approximately 2.5% of the myomas are pedunculated and can protrude in the cervical canal. Symptomatic leiomyomas can be treated either by hysterectomy or myomectomy, and these procedures can be performed with several techniques. Whenever possible, hysteroscopic myomectomy is better because it has many advantages, as it also preserves future fertility. Two interesting cases of prolapsed pedunculated submucous leiomyomas are reported in order to prove that magnetic resonance imaging (MRI) is essential to choose the most appropriate treatment and to perform an adequate presurgical planning, which must be based on an overall assessment of the leiomyoma's characteristics (number, location, size and presence or absence of a stalk) and the patient's characteristics.


Assuntos
Leiomioma/diagnóstico , Neoplasias Uterinas/diagnóstico , Adulto , Diagnóstico Diferencial , Feminino , Humanos , Leiomioma/patologia , Leiomioma/cirurgia , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Miomectomia Uterina , Neoplasias Uterinas/patologia , Neoplasias Uterinas/cirurgia
2.
Case Rep Oncol Med ; 2014: 961675, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24744931

RESUMO

Uterine leiomyosarcoma (ULMS) is an uncommon malignancy that accounts for one-third of uterine sarcomas and represents 1% of all uterine malignancies, with an incidence averaging 0.5-1/100,000/year. The prognosis is poor due to its intrinsic aggressiveness and its characteristic high metastatic potential with reported distant metastatic spread in lung, abdomen, soft tissue, and brain. We present the case of a 67-year-old woman with lung metastasis after eighteen years since uterine leiomyosarcoma diagnosis and its following surgical resection. The diagnosis of pulmonary metastases was obtained by reviewing the histology of the previous uterine tumor: the tumor cells were immunoreactive for CD10, PR, and smooth muscle actin (SMA), but negative for desmin, S100, CD34, CD 117, cytokeratins AE1AE3, CD68R, and ER. To our knowledge, this disease-free interval is the longest among previous reports of pulmonary metastasis of uterine leiomyosarcoma.

3.
Clin Radiol ; 68(11): e601-8, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23916550

RESUMO

AIM: To evaluate the problems that may arise in breast magnetic resonance imaging (MRI) related to the presence of artefacts and pitfalls, in order to improve its accuracy, sensitivity, and specificity. MATERIALS AND METHODS: Six hundred and thirty breast MRI examinations performed using a 1.5 T magnet were analysed retrospectively. Each type of artefact that may have affected the correct interpretation of the acquired images was considered and analysed. In particular, the presence of technical artefacts, which are related to patient-dependent factors or to the examination itself, and non-technical artefacts, which are the result of inadequate and incorrect image interpretation occurring in absence of technical issues, were examined. In every case of suspicious findings, doubtful lesions were subjected to histological characterization for appropriate therapeutic planning. In the remainder of cases, patients underwent follow-up for at least 18 months. RESULTS: Artefacts were found in 33% of all examinations, among those 48.6% were caused by movement, 33.6% were due to non-homogeneous or failed fat saturation, 8.7% to incorrect positioning of the patient, 7.2% to metallic artefacts, 1.4% to aliasing, and 0.5% were "zebra artefacts". When the artefact was identified in a sequence, the sequence was performed a second time after corrective measures. No artefacts affected diagnostic interpretation of the obtained images. CONCLUSION: The present study provides a specific and precise review of the most frequent artefacts with a discussion of possible and practical solutions. A highly qualified team is required to perform accurate diagnostic tests and to limit or remove the possibility of misinterpretation.


Assuntos
Artefatos , Doenças Mamárias/diagnóstico , Mama/patologia , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Gadolínio DTPA , Humanos , Aumento da Imagem/métodos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
4.
Clin Radiol ; 68(6): e293-300, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23541093

RESUMO

AIM: To assess the feasibility of magnetic resonance defaecography (MRD) in pelvic floor disorders using an open tilting magnet with a 0.25 T static field and to compare the results obtained from the same patient both in supine and orthostatic positions. MATERIALS AND METHODS: From May 2010 to November 2011, 49 symptomatic female subjects (mean age 43.5 years) were enrolled. All the patients underwent MRD in the supine and orthostatic positions using three-dimensional (3D) hybrid contrast-enhanced (HYCE) sequences and dynamic gradient echo (GE) T1-weighted sequences. All the patients underwent conventional defaecography (CD) to correlate both results. Two radiologists evaluated the examinations; inter and intra-observer concordance was measured. The results obtained in the two positions were compared between them and with CD. RESULTS: The comparison between CD and MRD found statistically significant differences in the evaluation of anterior and posterior rectocoele during defaecation in both positions and of rectal prolapse under the pubo-coccygeal line (PCL) during evacuation, only in the supine position (versus MRD orthostatic: rectal prolapse p < 0.0001; anterior rectocoele p < 0.001; posterior rectocoele p = 0.008; versus CD: rectal prolapse p < 0.0001; anterior rectocoele p < 0.001; posterior rectocoele p = 0.01). The value of intra-observer intra-class correlation coefficient (ICC) ranged from good to excellent; the interobserver ICC from moderate to excellent. CONCLUSION: MRD is feasible with an open low-field tilting magnet, and it is more accurate in the orthostatic position than in the supine position to evaluate pelvic floor disorders.


Assuntos
Defecografia/métodos , Imageamento por Ressonância Magnética/métodos , Distúrbios do Assoalho Pélvico/patologia , Adulto , Idoso , Constipação Intestinal/diagnóstico , Constipação Intestinal/patologia , Defecação , Incontinência Fecal/diagnóstico , Incontinência Fecal/patologia , Feminino , Humanos , Pessoa de Meia-Idade , Diafragma da Pelve/patologia , Distúrbios do Assoalho Pélvico/diagnóstico , Postura , Decúbito Dorsal , Adulto Jovem
5.
Radiol Med ; 116(4): 620-33, 2011 Jun.
Artigo em Inglês, Italiano | MEDLINE | ID: mdl-21424567

RESUMO

PURPOSE: This study was undertaken to explore the capabilities of an open-configuration, low-field, tilting, magnetic resonance (MR) system for investigating pelvic floor disorders and to compare the results obtained with the patient in the semiorthostatic and supine positions. MATERIALS AND METHODS: Eighteen female patients with a diagnosis of pelvic floor disorder (physical examination and conventional defecography) underwent dynamic MR defecography (MRD) with a 0.25-T tilting MR system (G-scan, Esaote). Images were obtained after administration of contrast agent into the rectum, bladder and vagina in both the orthostatic and supine positions. Three-dimensional T2-weighted hybrid contrast-enhanced (HYCE) sequences and dynamic T1-weighted gradient echo (GE) sequences were acquired at rest, during maximal contraction of the anal sphincter, straining and defecation. RESULTS: Good image quality was obtained in 15/18 patients; three presented severe artefacts due to motion, and three had incontinence, which hampered the functional studies. Better anatomical detail was obtained with MRD compared with conventional defecography. Three prolapses were observed in the semiorthostatic position only, and seven were found to be more severe in the orthostatic than in the supine position. CONCLUSIONS: Dynamic MRD with an open-configuration, low-field, tilting MR system is a feasible and promising tool for studying the pelvic floor. Larger series are necessary to assess its real diagnostic value.


Assuntos
Defecação , Imageamento por Ressonância Magnética/métodos , Prolapso de Órgão Pélvico/fisiopatologia , Adulto , Idoso , Feminino , Humanos , Pessoa de Meia-Idade , Diafragma da Pelve/patologia , Prolapso de Órgão Pélvico/diagnóstico , Retocele/diagnóstico , Retocele/fisiopatologia , Adulto Jovem
6.
Oral Implantol (Rome) ; 3(3): 2-10, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23285385

RESUMO

AIM: The aim of the study is to evaluate the incidence of different expansive lesions and the advantages of the clinical employment of Dentalscan to study bones lesions and to establish a common diagnostic path. MATERIALS AND METHODS: Since January 2005 to November 2009, 3200 patients, not selected for sex or age, have undergone a CT "Dentalscan" in the department of Diagnostic Imaging, Tor Vergata University Hospital (PTV), a suspect bone pathology was found in 704 of them through the XR-orthopantomograpy (OPT). CT images were obtained with General Electric CT Light Speed multislice. Images were saved in the Advantage Workstation (GE) supported by the "Dentascan" dedicated software and by the 3D software (3D SSD). The protocol was : Slice thickness 1,25 mm, gap 0, matrix 512 × 512, 140 KV and 70 mA. All the lesions were also studied with the dedicated three-dimensional reconstructor 3D SSD. Biopsy for diagnosis was performed on all the lesions, except one (false positive with digital OPT). THE TECHNIQUE SENSITIVITY WAS ASSESSED FOR TWO IMPORTANT CLASSES: benign and malignant lesions. RESULTS: Through CT Dentascan a detailed evaluation of the jaws lesions and their extension was obtained. 656 patients (93.1 %) out of 704 examined for a suspicious lesion on the orthopantomography had a benign lesion: (127 follicular cysts (18.2 %), 181 radicular cysts (25.1%), 93 non odontogenic cysts (13.2%), 29 fibroma (4.2%), 198 odontomes (28.2%), 24 ameloblastoma (3.6%), 4 brown tumors (0.7%), 47 (6.9%) had malignant lesions: (12 carcinoma (1.7%), 29 metastasis (4.3%), 6 sarcoma (0.8%), 1 Dentascan CT resulted to be negative (1 false positive of digital OPT). The sensitivity of the technique for both groups was 99% for benign lesions and 98% for malign lesions. CONCLUSIONS: CT Dentascan characteristics suggest to consider these techniques as the gold standard for the evaluation of jaw expansive lesions and the support of surgical planning.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...