Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Neurophysiol ; 131(10): 2341-2348, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32828036

RESUMO

OBJECTIVE: To study motor cortex plasticity after a period of training with a new prototype of bidirectional hand prosthesis in three left trans-radial amputees, correlating these changes with the modification of Phantom Limb Pain (PLP) in the same period. METHODS: Each subject underwent a brain motor mapping with Transcranial Magnetic Stimulation (TMS) and PLP evaluation with questionnaires during a six-month training with a prototype of bidirectional hand prosthesis. RESULTS: The baseline motor maps showed in all three amputees a smaller area of muscles representation of the amputated side compared to the intact limb. After training, there was a partial reversal of the baseline asymmetry. The two subjects affected by PLP experienced a statistically significant reduction of pain. CONCLUSIONS: Two apparently opposite findings, the invasion of the "deafferented" cortex by neighbouring areas and the "persistence" of neural structures after amputation, could vary according to different target used for measurement. Our results do not support a correlation between PLP and motor cortical changes. SIGNIFICANCE: The selection of the target and of the task is essential for studies investigating motor brain plasticity. This study boosts against a direct and unique role of motor cortical changes on PLP genesis.


Assuntos
Amputação Cirúrgica , Potencial Evocado Motor/fisiologia , Córtex Motor/fisiopatologia , Músculo Esquelético/fisiopatologia , Plasticidade Neuronal/fisiologia , Próteses e Implantes , Amputados , Mapeamento Encefálico , Feminino , Mãos/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade
2.
Sci Rep ; 9(1): 19258, 2019 12 17.
Artigo em Inglês | MEDLINE | ID: mdl-31848384

RESUMO

Although peripheral nerve stimulation using intraneural electrodes has been shown to be an effective and reliable solution to restore sensory feedback after hand loss, there have been no reports on the characterization of multi-channel stimulation. A deeper understanding of how the simultaneous stimulation of multiple electrode channels affects the evoked sensations should help in improving the definition of encoding strategies for bidirectional prostheses. We characterized the sensations evoked by simultaneous stimulation of median and ulnar nerves (multi-channel configuration) in four transradial amputees who had been implanted with four TIMEs (Transverse Intrafascicular Multichannel Electrodes). The results were compared with the characterization of single-channel stimulation. The sensations were characterized in terms of location, extent, type, and intensity. Combining two or more single-channel configurations caused a linear combination of the sensation locations and types perceived with such single-channel stimulations. Interestingly, this was also true when two active sites from the same nerve were stimulated. When stimulating in multi-channel configuration, the charge needed from each electrode channel to evoke a sensation was significantly lower than the one needed in single-channel configuration (sensory facilitation). This result was also supported by electroencephalography (EEG) recordings during nerve stimulation. Somatosensory potentials evoked by multi-channel stimulation confirmed that sensations in the amputated hand were perceived by the subjects and that a perceptual sensory facilitation occurred. Our results should help the future development of more efficient bidirectional prostheses by providing guidelines for the development of more complex stimulation approaches to effectively restore multiple sensations at the same time.


Assuntos
Amputados , Membros Artificiais , Eletroencefalografia , Desenho de Prótese , Estimulação Elétrica Nervosa Transcutânea , Nervo Ulnar/fisiopatologia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
3.
Sci Rep ; 8(1): 16666, 2018 11 12.
Artigo em Inglês | MEDLINE | ID: mdl-30420739

RESUMO

Recent studies have shown that direct nerve stimulation can be used to provide sensory feedback to hand amputees. The intensity of the elicited sensations can be modulated using the amplitude or frequency of the injected stimuli. However, a comprehensive comparison of the effects of these two encoding strategies on the amputees' ability to control a prosthesis has not been performed. In this paper, we assessed the performance of two trans-radial amputees controlling a myoelectric hand prosthesis while receiving grip force sensory feedback encoded using either linear modulation of amplitude (LAM) or linear modulation of frequency (LFM) of direct nerve stimulation (namely, bidirectional prostheses). Both subjects achieved similar and significantly above-chance performance when they were asked to exploit LAM or LFM in different tasks. The feedbacks allowed them to discriminate, during manipulation through the robotic hand, objects of different compliances and shapes or different placements on the prosthesis. Similar high performances were obtained when they were asked to apply different levels of force in a random order on a dynamometer using LAM or LFM. In contrast, only the LAM strategy allowed the subjects to continuously modulate the grip pressure on the dynamometer. Furthermore, when long-lasting trains of stimulation were delivered, LFM strategy generated a very fast adaptation phenomenon in the subjects, which caused them to stop perceiving the restored sensations. Both encoding approaches were perceived as very different from the touch feelings of the healthy limb (natural). These results suggest that the choice of specific sensory feedback encodings can have an effect on user performance while grasping. In addition, our results invite the development of new approaches to provide more natural sensory feelings to the users, which could be addressed by a more biomimetic strategy in the future.


Assuntos
Membros Artificiais , Mãos/cirurgia , Retroalimentação Sensorial/fisiologia , Feminino , Mãos/fisiologia , Humanos , Pessoa de Meia-Idade
4.
Biomaterials ; 122: 114-129, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-28110171

RESUMO

Stimulation of peripheral nerves has transiently restored lost sensation and has the potential to alleviate motor deficits. However, incomplete characterization of the long-term usability and bio-integration of intra-neural implants has restricted their use for clinical applications. Here, we conducted a longitudinal assessment of the selectivity, stability, functionality, and biocompatibility of polyimide-based intra-neural implants that were inserted in the sciatic nerve of twenty-three healthy adult rats for up to six months. We found that the stimulation threshold and impedance of the electrodes increased moderately during the first four weeks after implantation, and then remained stable over the following five months. The time course of these adaptations correlated with the progressive development of a fibrotic capsule around the implants. The selectivity of the electrodes enabled the preferential recruitment of extensor and flexor muscles of the ankle. Despite the foreign body reaction, this selectivity remained stable over time. These functional properties supported the development of control algorithms that modulated the forces produced by ankle extensor and flexor muscles with high precision. The comprehensive characterization of the implant encapsulation revealed hyper-cellularity, increased microvascular density, Wallerian degeneration, and infiltration of macrophages within the endoneurial space early after implantation. Over time, the amount of macrophages markedly decreased, and a layer of multinucleated giant cells surrounded by a capsule of fibrotic tissue developed around the implant, causing an enlargement of the diameter of the nerve. However, the density of nerve fibers above and below the inserted implant remained unaffected. Upon removal of the implant, we did not detect alteration of skilled leg movements and only observed mild tissue reaction. Our study characterized the interplay between the development of foreign body responses and changes in the electrical properties of actively used intra-neural electrodes, highlighting functional stability of polyimide-based implants over more than six months. These results are essential for refining and validating these implants and open a realistic pathway for long-term clinical applications in humans.


Assuntos
Estimulação Elétrica/instrumentação , Neuroestimuladores Implantáveis , Microeletrodos , Resinas Sintéticas/química , Nervo Isquiático/fisiologia , Animais , Materiais Biocompatíveis/química , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Estudos Longitudinais , Ratos , Ratos Endogâmicos Lew , Nervo Isquiático/citologia , Resultado do Tratamento
5.
Clin Exp Obstet Gynecol ; 44(3): 480-482, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29949301

RESUMO

Primary benign and malign pericardial ind heart tumors are very rare (0.002-0.03%). Benign tumors of heart and pericardium are more frequent (myxoma, rhabdomyoma, lipoma, and papillary fibroelastoma of endocardium: 70% of all primary tumors). Because of low frequency, clinicians rarely and hardly diagnose these types of tumors. The affected patients wander from one healthcare center to another, usually with misleading diagnosis, such as cardiomyopathy or mitral stenosis. Pericardial and cardiac tumors cause pressure to surrounding structures. Because of the specific anatomy and function, all heart tumors are "malign by localization". Presence of benign pericardial tumor leads to pericardial effusion, fibrinohemorrhagic pericarditis, and cardiac tamponade. In the present study, the authors report a case of a female patient with pericardial cyst which was diagnosed during the second trimester of pregnancy. After undergoing multiple diagnostic procedures in short time period, the authors had accurate set of definitive diagnosis. The patient had successful surgical treatment and the pregnancy was continued until term without any fetal consequences.


Assuntos
Neoplasias Cardíacas/diagnóstico , Neoplasias Cardíacas/cirurgia , Complicações Neoplásicas na Gravidez/diagnóstico , Complicações Neoplásicas na Gravidez/cirurgia , Adulto , Tamponamento Cardíaco/etiologia , Feminino , Humanos , Pericárdio , Gravidez
6.
IEEE Trans Biomed Circuits Syst ; 5(4): 368-79, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23851951

RESUMO

This paper presents a portable, embedded, microcontroller-based system for bidirectional communication (recording and stimulation) between an electrode, implanted in the peripheral nervous system, and a host computer. The device is able to record and digitize spontaneous and/or evoked neural activities and store them in data files on a PC. In addition, the system has the capability of providing electrical stimulation of peripheral nerves, injecting biphasic current pulses with programmable duration, intensity, and frequency. The recording system provides a highly selective band-pass filter from 800 Hz to 3 kHz, with a gain of 56 dB. The amplification range can be further extended to 96 dB with a variable gain amplifier. The proposed acquisition/stimulation circuitry has been successfully tested through in vivo measurements, implanting a tf-LIFE electrode in the sciatic nerve of a rat. Once implanted, the device showed an input referred noise of 0.83 µVrms, was capable of recording signals below 10 µ V, and generated muscle responses to injected stimuli. The results demonstrate the capability of processing and transmitting neural signals with very low distortion and with a power consumption lower than 1 W. A graphic, user-friendly interface has been developed to facilitate the configuration of the entire system, providing the possibility to activate stimulation and monitor recordings in real time.

7.
Artigo em Inglês | MEDLINE | ID: mdl-21095936

RESUMO

The performance of motor neuroprostheses or robotic arm prostheses can be significantly improved by delivering sensory feed-back related to the ongoing motor task (e.g. the slippage of an object during grasping). Microfabricated neural electrodes implantable in peripheral nervous system seem a promising approach to this aim. New generation of thin-film intrafascicular electrodes longitudinally implantable in peripheral nerves (tf-LIFE4) has been developed and tested for afferent stimulation in human amputee case study.


Assuntos
Cotos de Amputação/fisiopatologia , Amputados/reabilitação , Eletrodos Implantados , Membranas Artificiais , Nervos Periféricos/fisiopatologia , Células Receptoras Sensoriais , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Masculino
8.
Artigo em Inglês | MEDLINE | ID: mdl-19963845

RESUMO

The development of hybrid neuroprosthetic systems (HBSs) linking the human nervous system with artificial devices is an important area of research that is currently addressed by several groups to restore sensorimotor function in people affected by different disabilities. It is particularly important to establish a fast, intuitive, bidirectional flow of information between the nervous system of the user and the smart robotic device. Among the possible solutions to achieve this goal, interfaces with the peripheral nervous system and in particular intraneural electrodes can represent an interesting choice. In the present study, thin-film longitudinal intra-fascicular electrodes were implanted in the median and ulnar nerves of an amputee. The possibility of restoring the bidirectional link between the subject and the external world was investigated during a 4 week trial. The result showed that both the extraction of motor information and the restoration of sensory function are possible.


Assuntos
Membros Artificiais , Potencial Evocado Motor/fisiologia , Sistema Nervoso Periférico/fisiologia , Robótica/métodos , Processamento de Sinais Assistido por Computador , Algoritmos , Amputados , Eletrodiagnóstico/métodos , Humanos , Sistemas Homem-Máquina , Nervo Mediano/fisiologia , Nervo Ulnar/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...