Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Australas Phys Eng Sci Med ; 27(1): 25-9, 2004 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15156705

RESUMO

A thermoluminescent dosimetry (TLD) postal dose inter-comparison was carried out amongst radiotherapy centres in Malaysia. The aim of this TLD inter-comparison was to compare the uniformity involved in the measurement of absorbed dose among the participating centres. A set of 5 TLD chips placed within acrylic trays were mailed to all participating centres for irradiation to an absorbed dose to water of 2 Gy. Measurements were made for 6 MV and 60Co photon beams. Results show an agreement of +/- 5% for all but three radiotherapy centres. The ratios of the TLD readings to that of the reference centre are comparable with other national/regional dose inter-comparisons. The importance of a proper ongoing quality assurance program is essential in maintaining the consistency and uniformity of doses delivered.


Assuntos
Auditoria Médica/normas , Serviço Hospitalar de Medicina Nuclear/normas , Garantia da Qualidade dos Cuidados de Saúde/métodos , Garantia da Qualidade dos Cuidados de Saúde/normas , Dosagem Radioterapêutica/normas , Planejamento da Radioterapia Assistida por Computador/normas , Radioterapia/normas , Dosimetria Termoluminescente/normas , Análise de Falha de Equipamento/instrumentação , Análise de Falha de Equipamento/métodos , Análise de Falha de Equipamento/normas , Malásia , Auditoria Médica/métodos , Controle de Qualidade , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
Med J Malaysia ; 54(2): 185-91, 1999 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10972028

RESUMO

X-ray based radiological procedure statistics and trend in Malaysia for 1990-1994 is reported; this information allows comparisons to be made with the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) Report. Additionally it is essential information for health care planners and providers. Malaysia is categorised as a health care level II country based on the UNSCEAR definition. In 1994, the number of physicians, radiologists, x-ray units and x-ray examinations per 1000 population was 0.45, 0.005, 0.065 and 183 respectively. 3.6 million x-ray examinations were performed in 1994, with chest radiography being the commonest study (63%). Information on x-ray examinations, number of hospitals and x-ray units is reported for the Ministry of Health, private practice and teaching hospitals. Examination frequency increased in computed tomography (161%), cardiac procedures (190%), and mammography (240%); while a decrease in barium studies (-23%), cholecystography (-36%), and intravenous urography (-51%) was noted. There is a potential and need to expand and upgrade radiological services.


Assuntos
Radiografia , Humanos , Malásia
3.
Br J Radiol ; 71(846): 654-60, 1998 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-9849390

RESUMO

A collaborative national survey initiated by the University of Malaya and the Ministry of Health was conducted from 1993 to 1995 to establish baseline patient dose data for seven common types (12 projections) of X-ray examinations in Malaysia. A total of 12 randomly selected public hospitals and 867 patients were included in this survey. The entrance surface doses (ESD) received by the patients were measured using thermoluminescent dosemeters (TLDs) attached to the patient's skin. Histograms are presented showing wide, positively skewed distributions of measured entrance surface doses for each examination. Mean, median, first and third quartile values of ESD and median effective dose are reported. Survey results are generally comparable with those reported in the UK, USA and by the International Atomic Energy Agency (IAEA). The results also provide information on dose level for a lower weight population (mean weight 60 kg) compared with the international reference dose values based on a 70 kg standard. The findings support the importance of the on-going national quality assurance programme to ensure doses are kept to a level consistent with optimum image quality. The data will also be useful for the formulation of national guidance levels as recommended by the IAEA. Furthermore, this study provides patient dosimetry information on healthcare level II countries.


Assuntos
Doses de Radiação , Radiografia , Adulto , Idoso , Inquéritos Epidemiológicos , Humanos , Malásia , Pessoa de Meia-Idade , Valores de Referência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...