Iran J Med Sci ; 47(4): 338-349, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35919083

RESUMO

Background: The present study aimed to evaluate the effectiveness of ultra-low-dose (ULD) chest computed tomography (CT) in comparison with the routine dose (RD) CT images in detecting lung lesions related to COVID-19. Methods: A prospective study was conducted during April-September 2020 at Shahid Faghihi Hospital affiliated with Shiraz University of Medical Sciences, Shiraz, Iran. In total, 273 volunteers with suspected COVID-19 participated in the study and successively underwent RD-CT and ULD-CT chest scans. Two expert radiologists qualitatively evaluated the images. Dose assessment was performed by determining volume CT dose index, dose length product, and size-specific dose estimate. Data analysis was performed using a ranking test and kappa coefficient (κ). P<0.05 was considered statistically significant. Results: Lung lesions could be detected with both RD-CT and ULD-CT images in patients with suspected or confirmed COVID-19 (κ=1.0, P=0.016). The estimated effective dose for the RD-CT protocol was 22-fold higher than in the ULD-CT protocol. In the case of the ULD-CT protocol, sensitivity, specificity, accuracy, and positive predictive value for the detection of consolidation were 60%, 83%, 80%, and 20%, respectively. Comparably, in the case of RD-CT, these percentages for the detection of ground-glass opacity (GGO) were 62%, 66%, 66%, and 18%, respectively. Assuming the result of real-time polymerase chain reaction as true-positive, analysis of the receiver-operating characteristic curve for GGO detected using the ULD-CT protocol showed a maximum area under the curve of 0.78. Conclusion: ULD-CT, with 94% dose reduction, can be an alternative to RD-CT to detect lung lesions for COVID-19 diagnosis and follow-up.An earlier preliminary report of a similar work with a lower sample size was submitted to the arXive as a preprint. The preprint is cited as: https://arxiv.org/abs/2005.03347.


Assuntos
COVID-19 , Teste para COVID-19 , Humanos , Pulmão/diagnóstico por imagem , Estudos Prospectivos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos
2.
J Biomed Phys Eng ; 11(4): 447-458, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34458192

RESUMO

BACKGROUND: The diagnostic reference level (DRL) is measured with different methods in the common Computed tomography (CT) exams, but it has not been measured through the size-specific dose estimate (SSDE) method in Iran, yet. OBJECTIVE: This study aimed to calculate the local DRL (LDRL) using the new quality control-based dose survey method (QC) and patients' effective diameter (MQC) and compare them with a data collection method (DC) as well as local national DRLs (NDRL). MATERIAL AND METHODS: In this cross-sectional study, LDRL, based on the third quartile of volumetric computed tomography dose index (CTDIvol) and dose length product (DLP) values, was calculated for the four common CT examinations in four CT scan centers affiliated with Shiraz University of Medical Sciences by DC, QC and MQC methods. The CTDIvol of each patient for each CT exam calculated with three methods was compared with paired t-test. Also, the LDRL using MQC method was compared with other national DRL studies. RESULTS: There was a significant difference between the CTDIvol values calculated with MQC and QC in all four examinations (P <0.001). The LDRL based on CTDIvol obtained by the MQC method for head, sinus, chest, abdomen, and pelvis were (50, 18, 15, 19) mGy, respectively, and the calculated DLP values were also (735, 232, 519, 984) mGy.cm. CONCLUSION: In MQC, LDRL based on CTDIvol was calculated with a mean difference percentage of (19.2 ± 11.6)% and (27.1 ± 8.1)% as compared to the QC and DC methods, respectively. This difference resulted from the use of the SSDE method and dose accuracy in the QC dose survey.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...