1.
Phys Med Biol ; 44(10): N223-31, 1999 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-10533938

RESUMO

The aim of this study is to develop collimator inserts of various sizes which are either not commercially available or are expensive to import. The dosimetry parameters such as tissue maximum ratio (TMR), off-axis ratio (OAR) and output factor of the developed collimator insert are compared with that of the commercial collimator insert (Radionics). In order to check the suitability of the collimator insert developed locally for clinical use and to standardize the method of development, a collimator insert of 15 mm identical to the one supplied by Radionics is developed with low-melting alloy (Cerrobend). Moreover for the clinical use of the developed collimator insert, certain acceptance tests are performed which include a collimator concentricity test, beam size check and radiation leakage test. The dose verification is carried out with a thermoluminescent dosimeter (7LiF rods) and an FBX chemical dosimeter in a human-head-shaped Perspex phantom filled with water. The variation between the calculated and measured dose is found to be within +2.4% for 7LiF rods and -2.0% for the FBX chemical dosimeter thus ensuring the suitability of the developed collimator insert for clinical use. This has encouraged us to standardize the method adapted to develop the collimator insert and to develop collimator inserts of different field sizes.


Assuntos
Radiocirurgia/métodos , Radioterapia/métodos , Técnicas Estereotáxicas , Desenho de Equipamento , Cabeça , Humanos , Aceleradores de Partículas/normas , Imagens de Fantasmas , Garantia da Qualidade dos Cuidados de Saúde , Radiocirurgia/instrumentação , Radiocirurgia/normas , Radioterapia/instrumentação , Radioterapia/normas , Técnicas Estereotáxicas/normas
2.
Phys Med Biol ; 44(5): 1309-15, 1999 May.
Artigo em Inglês | MEDLINE | ID: mdl-10368021

RESUMO

The virtual source position (VSP) for electron beams of energies 5, 7, 9 10, 12 and 14 MeV and for the applicators (cones) available in the department have been measured for a Mevatron MD class linear accelerator. Different methods of obtaining the virtual source position for electron beams have been investigated in the present study. The results obtained have been compared with those of other workers. It is observed that the VSP is very much machine dependent and needs to be measured for each linear accelerator. The effect of shielding on virtual source position for the type of applicators available in the department has also been investigated.


Assuntos
Elétrons , Aceleradores de Partículas/instrumentação , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Alta Energia/instrumentação , Ar , Fenômenos Biofísicos , Biofísica , Humanos , Neoplasias/radioterapia , Planejamento da Radioterapia Assistida por Computador/estatística & dados numéricos