Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Thromb Thrombolysis ; 43(4): 437-445, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28247290

RESUMO

Non vitamin K oral anticoagulants (NOACs) do not require regular monitoring but information about their pharmacodynamic effect may be importantin situations like trauma, stroke oremergent surgery. Currently, no standardized point-of-care test is available to evaluate the anticoagulant effects of NOACs. We evaluated the anticoagulant effect of NOACs with the next generation point-of-care TEG assay (TEG® 6S) based on a fully-automated thrombelastography system. We used two TEG® 6S assays, the DTI assay and Anti-Factor Xa (AFXa) assay, to detect anticoagulant effects and classify NOACs. Blood from healthy volunteers (n = 26) was used to obtain a baseline reference range. Data derived from patients on factor Xa inhibitors (FXi) (rivaroxaban and apixaban) (n = 39), and direct thrombin inhibitors (DTIs) (dabigatran) (n = 25) were compared against the reference range for detection of drug effect and drug classification. TEG®6s R-time highly correlated to each NOAC. Presence of NOACs caused elongation of R-time on the AFXa assay compared to the reference range (4.3 ± 1.7 vs. 1.3 ± 0.3 min. for FXi, p < 0.001 and 3.5 ± 1.2 vs. 1.3 ± 0.3 min. for DTI, p < 0.001). R-time on the DTI assay was elongated only in presence of a DTI (3.4 ± 1.0 vs. 1.5 ± 0.2 min, p < 0.001). The cutoff for detection of a DTI effect was an R time of 1.9 min and for anti-Xa effect was 1.95 min. For detection of NOAC therapy, there was ≥92% sensitivity and ≥95% specificity. The automated TEG®6s NOAC assay may be an effective tool to identify an anticoagulant effect from NOAC therapy and facilitate care of patients with bleeding or at risk of bleeding in the event of needing emergency surgery.


Assuntos
Anticoagulantes/uso terapêutico , Tromboelastografia/métodos , Adulto , Antitrombinas/uso terapêutico , Automação , Dabigatrana/uso terapêutico , Monitoramento de Medicamentos/instrumentação , Monitoramento de Medicamentos/métodos , Monitoramento de Medicamentos/normas , Inibidores do Fator Xa/uso terapêutico , Feminino , Hemorragia/induzido quimicamente , Hemorragia/diagnóstico , Humanos , Limite de Detecção , Masculino , Pessoa de Meia-Idade , Sistemas Automatizados de Assistência Junto ao Leito , Pirazóis/uso terapêutico , Piridonas/uso terapêutico , Rivaroxabana/uso terapêutico , Tromboelastografia/instrumentação , Tromboelastografia/normas
2.
Platelets ; 27(7): 642-649, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27809712

RESUMO

Thrombelastography (TEG) measured by the TEG5000 Hemostasis Analyzer is an established but the labor-intensive method for assessing global hemostasis. The first true point-of-care TEG, the TEG6s system, uses resonance-frequency viscoelasticity measurements and a disposable multi-channel microfluidic cartridge to assess hemostasis and response to antiplatelet therapy. TEG assays (n = 5,100) were performed on the blood of healthy volunteers (n = 157) and patients undergoing coronary revascularization at three hospitals (n = 300). The results from the TEG6s were compared with the conventional TEG5000 in accordance with Clinical and Laboratory Standards Institute (CLSI) and FDA recommendations. Precision testing was conducted using blood from healthy donors, all assays were run for 5 consecutive days in duplicate using multiple operators, lots, and instruments. Reference ranges were comparable between the TEG systems. Deming regression analysis demonstrated a strong correlation between the two systems for the standard hemostasis tests (R r = 0.932, MA r = 0.972, LY30 r = 0.938). Method comparison analysis showed an acceptable agreement between PlateletMapping (PM) assays for measuring arachidonic acid (indicator of aspirin response)- and adenosine diphosphate (indicator of P2Y12 inhibitor response)-induced platelet aggregation (total agreement = 90%, and 72%, respectively). TEG6s precision testing yielded low variability (CV 0-13%) in all measures. The new point-of-care TEG6s is associated with greater ease of use than the TEG5000 and provides precise results. The results correlated between methods for all variables. TEG6s is a promising device for near-patient hemostasis monitoring and future trials of personalized therapy designed to reduce bleeding and thrombosis.


Assuntos
Sistemas Automatizados de Assistência Junto ao Leito , Tromboelastografia/métodos , Procedimentos Cirúrgicos Cardíacos , Feminino , Hemostasia , Humanos , Masculino , Intervenção Coronária Percutânea , Agregação Plaquetária/efeitos dos fármacos , Inibidores da Agregação Plaquetária/farmacologia , Inibidores da Agregação Plaquetária/uso terapêutico , Testes de Função Plaquetária/métodos , Testes de Função Plaquetária/normas , Valores de Referência , Reprodutibilidade dos Testes , Tromboelastografia/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...