Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Phys Condens Matter ; 36(29)2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38588673

RESUMO

Here, we report the influence of Jahn-Teller active Cu substitution on the charge-ordering (CO) characteristics of one of the well-known manganite Pr0.45Sr0.55MnO3(S55) with a distorted tetragonal structure. Magnetization studies unveil a complex magnetic phase diagram for S55, showing distinct temperature ranges corresponding to various magnetic phases: a ferromagnetic phase dominated by the Double Exchange interaction withTC∼ 220.5 K, an antiferromagnetic phase belowTN∼ 207.6 K induced by CO with a transition temperature ofTCO∼ 210 K consistent with the specific heatCP(T) data, and a mixed phase in the rangeTNTN(T

2.
J Phys Condens Matter ; 34(34)2022 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-35584687

RESUMO

A detailed crystal structure analysis, temperature and field dependence of magnetic characteristics and phonon instabilities for different compositions (0.1 ⩽x⩽ 0.5) of Dy1-xCexCrO3solid-solutions have been reported. All the investigated compounds exhibit distorted orthorhombic crystal structure with a distortion factor ofdOct/dCell∼ 6 × 10-3/3.5 ppm (forx∼ 0.2) forPbnmspace group that follows Vegard's law. The bonds between apical oxygen atoms (OA1) and Cr atoms stand more rigidly in comparison with the basal oxygen atoms (OB1/OB2) resulting the octahedral distortion and thereby causing the changes in phonon modes. The CrO6octahedral tilt angleθrotates with respect to the Miller pseudocubic axis [101] which varies from 10.36° (x= 0.1) to 12.25° (x= 0.5) and significantly influences the Ag(5) phonon stability by 3% for a change in A-site mean radius from 1.095 Å to 1.141 Å forx= 0.1 and 0.5, respectively. From the magnetization measurements we find that these series of compositions exhibit canted antiferromagnetic (AFM) ordering with Néel temperature,TN1that increases from 151.8 K (x= 0.1) to 162 K (x= 0.5) which also manifests as a significant reduction in the magneto-crystalline anisotropy (HK∼ 2.58 kOe → 2.07 kOe,K1∼ 36.47 J m-3→ 18.97 J m-3) while maintaining the stable Γ4(Gx,Ay,Fz) AFM configuration. Both Dzyaloshinskii-Moriya interaction method and modified Curie-Weiss law are employed to analyse the inverse paramagnetic susceptibility,χ-1(T>TN1). Further, we have evaluated the symmetric (JS) and antisymmetric exchange (DAS) constants, which show progressively increasing trend (JS→ 10.08 K to 11.18 K andDAS→ 1.24 K to 1.73 K) with the incorporation of Ce inside the perovskite lattice. Furthermore, the role of Ce substitution on the low-temperature spin reorientation transition (TSR∼ 3.5 K → 16.8 K pertaining to the Γ25phase configuration) and emergence ofΓ2(Fx,Cy,Gz;FxR,CyR)weak-FM phase between 31 K and 45.5 K are discussed in consonance with the phonon spectra.

3.
J Phys Condens Matter ; 34(6)2021 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-34710855

RESUMO

We report a systematic study of the magnetic phase diagram in theH-Tplane, negative magnetization (NM), exchange interactions and field-induced spin-flop transitions in the distorted perovskite Y1-xCexCrO3. Locked AFM and weak-FM configurations in Γ4(Gz,Fy,Ax) phase of YCrO3(S= 3/2 ground state) unlocks into the Γ2(Fz,Gy,Cx;FzR,CxR) phase of the canted AFM and FM structures with the dilute substitution of Ce (x⩾ 0.05). The asymmetric and symmetric exchange interaction (JAS∼ 0.11 meV andJS∼ 0.85 meV) between the trivalent Ce and Cr enable the positive quartic-anisotropy field (HK4∼ 2.85 × 102Oe) along with the second order anisotropy field (HK2∼ 5.93 × 102Oe). Unlike the pristine YCrO3compound, the Ce incorporated system exhibits a giant fourth-order anisotropy constant (K4= 1.35 × 105erg/c.c.) due to the asymmetric exchange interaction between the trivalent Ce-Cr which further lifts the free energy of the system and causes lag in the onset of AFM ordering showing the significant thermal hysteresis (ΔT∼ 10 K) in the field-cooled (FC)-warming measurement protocol as compared to the FC-cooling mode. The H-T phase diagram, mapped from the isothermal magnetization data and differential magnetic susceptibility data with different measurement protocols clearly distinguishes three prominent regions below theTN(∼150 K), viz (i) long-range canted AFM + weak FM phase (Γ4(Gz,Fy,Ax)), (ii) Γ24mixed phase and (iii) robust Γ2(Fz,Gy,Cx;FzR,CxR) AFM + FM phases. Tunable spin-flopped transition (∼ 30 kOe), significant negative exchange-bias field (HEB∼ 2.5 kOe), huge coercive field (HC∼ 22 kOe) and large NM (ΔM∼ 280 emu/mole) are the unique characteristic features of the current investigated system.

4.
Rev Sci Instrum ; 87(11): 11E315, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910569

RESUMO

X-ray spectroscopy is a useful tool for diagnosing plasma sources due to its non-invasive nature. One such source is the dense plasma focus (DPF). Recent interest has developed to demonstrate its potential application as a soft x-ray source. We present the first spectroscopic studies of krypton high energy density plasmas produced on a 3 kJ DPF device in Singapore. In order to diagnose spectral features, and to obtain a more comprehensive understanding of plasma parameters, a new non-local thermodynamic equilibrium L-shell kinetic model for krypton was developed. It has the capability of incorporating hot electrons, with different electron distribution functions, in order to examine the effects that they have on emission spectra. To further substantiate the validity of this model, it is also benchmarked with data gathered from experiments on the electron beam ion trap (EBIT) at Lawrence Livermore National Laboratory, where data were collected using the high resolution EBIT calorimeter spectrometer.

5.
Acta Biomater ; 7(3): 1319-26, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20920614

RESUMO

In magnetic particle assisted gene delivery DNA is complexed with polymer-coated aggregated magnetic nanoparticles (AMNPs) to effect transfection. In vitro studies based on COS-7 cells were carried out using pEGFP-N1 and pMIR-REPORT-complexed, polyethylenimine (PEI)-coated iron oxide magnetic nanoparticles (MNPs). PEI-coated AMNPs (PEI-AMNPs) with average individual particle diameters of 8, 16 and 30 nm were synthesized. Normal, reverse and retention magnetic transfection experiments and cell wounding assays were performed. Our results show that the optimum magnetic field yields maximum transfection efficiency with good viability. The results of the normal, reverse and retention magnetic transfection experiments show that the highest transfection efficiency was achieved in normal magnetic transfection mode due to clustering of the PEI-AMNPs on the cells. Cell wounding assay results suggest that the mechanism of magnetic transfection is endocytosis rather than cell wounding.


Assuntos
Magnetismo , Transfecção/métodos , Animais , Células COS , Chlorocebus aethiops
6.
Rev Sci Instrum ; 81(8): 083506, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20815606

RESUMO

Yttrium is presented as an absolute neutron detector for pulsed neutron sources. It has high sensitivity for detecting fast neutrons. Yttrium has the property of generating a monoenergetic secondary radiation in the form of a 909 keV gamma-ray caused by inelastic neutron interaction. It was calibrated numerically using MCNPX and does not need periodic recalibration. The total yttrium efficiency for detecting 2.45 MeV neutrons was determined to be f(n) approximately 4.1x10(-4) with an uncertainty of about 0.27%. The yttrium detector was employed in the NX2 plasma focus experiments and showed the neutron yield of the order of 10(8) neutrons per discharge.

7.
Rev Sci Instrum ; 78(8): 086107, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17764367

RESUMO

We report the design and development of insulated gate bipolar junction transistor based high performance driver for operating thyratrons in grounded grid mode. With careful design, the driver meets the specification of trigger output pulse rise time less than 30 ns, jitter less than +/-1 ns, and time delay less than 160 ns. It produces a -600 V pulse of 500 ns duration (full width at half maximum) at repetition rate ranging from 1 Hz to 1.14 kHz. The developed module also facilitates heating and biasing units along with protection circuitry in one complete package.


Assuntos
Amplificadores Eletrônicos , Eletrônica/instrumentação , Processamento de Sinais Assistido por Computador/instrumentação , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
Appl Spectrosc ; 58(11): 1288-94, 2004 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18070406

RESUMO

Future applications of microelectromechanical systems (MEMS) require lithographic performance of very high aspect ratio. Chemically amplified resists (CARs) such as the negative tone commercial SU-8 provide critical advantages in sensitivity, resolution, and process efficiency in deep ultraviolet, electron-beam, and X-ray lithographies (XRLs), which result in a very high aspect ratio. In this investigation, an SU-8 resist was characterized and optimized for X-ray lithographic applications by studying the cross-linking process of the resist under different conditions of resist thickness and X-ray exposure dose. The exposure dose of soft X-ray (SXR) irradiation at the average weighted wavelength of 1.20 nm from a plasma focus device ranges from 100 to 1600 mJ/cm(2) on the resist surface. Resist thickness varies from 3.5 to 15 mum. The cross-linking process of the resist during post-exposure bake (PEB) was accurately monitored using Fourier transform infrared (FT-IR) spectroscopy. The infrared absorption peaks at 862, 914, 972, and 1128 cm(-1) in the spectrum of the SU-8 resist were found to be useful indicators for the completion of cross-linking in the resist. Results of the experiments showed that the cross-linking of SU-8 was optimized at the exposure dose of 800 mJ/cm(2) for resist thicknesses of 3.5, 9.5, and 15 microm. PEB temperature was set at 95 degrees C and time at 3 min. The resist thickness was measured using interference patterns in the FT-IR spectra of the resist. Test structures with an aspect ratio 3:1 on 10 microm thick SU-8 resist film were obtained using scanning electron microscopy (SEM).

12.
J Assoc Physicians India ; 37(3): 201-3, 1989 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-2768161

RESUMO

Thirty thrombocytopaenic patients of acute leukaemias and myelodysplastic syndrome were transfused platelets collected from ABO-matched donors using Haemonetics V30 and V50 blood processors. Twenty-seven patients had septicaemia and/or splenomegaly; 2 patients had disseminated intravascular coagulation (DIC). Pre-transfusion platelet count was 11.0 +/- 4.0 X 10(9)/L. The mean corrected count increments (CCI) 1 hour and 18 hours post-transfusion were 13.02 X 10(9)/L and 3.88 X 10(9)/L respectively, in the absence of DIC. Active bleeding stopped when platelet count was above 15.0 X 10(9)/L. There was no difference between the platelet yield from two blood processors.


Assuntos
Transfusão de Sangue , Leucemia/complicações , Síndromes Mielodisplásicas/complicações , Transfusão de Plaquetas , Trombocitopenia/prevenção & controle , Doença Aguda , Adolescente , Adulto , Criança , Pré-Escolar , Humanos , Pessoa de Meia-Idade , Trombocitopenia/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...