Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
J Alzheimers Dis ; 34(1): 315-23, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23168448

RESUMO

Recent studies have suggested that memory circuits can be modulated by deep brain stimulation (DBS). This propriety might be used to slow down cognitive decline in patients suffering from Alzheimer's disease (AD). We conducted a prospective study to evaluate the feasibility and safety of DBS in AD patients with mild cognitive decline. Inclusion criteria were: patients (<70 years old) with AD diagnosed for less than 2 years, predominant impairment of episodic memory, and Mini-Mental Status Exam (MMSE) score between 20 and 24. The fornix was stimulated bilaterally by electrodes implanted stereotactically in the hypothalamus. Clinical, biological, neuropsychological, and imaging evaluations were conducted 3 months before surgery and 3, 6, and 12 months thereafter. During the one year-period of inclusion, 110 patients with recently diagnosed AD and predominant impairment of episodic memory were screened. Only 9 patients (8.2%) fulfilled all the inclusion criteria. Finally, just one patient accepted to be operated (acceptance rate 11.1%) and completed the study. No complications occurred and the stimulation was perfectly tolerated. After one year of stimulation, the memory scores (MMSE, ADAS-Cog, Free and Cued Selective Reminding Test) were stabilized compared to baseline, and mesial temporal lobes metabolism increased. This pilot study provides new data about the safety of fornix DBS in the hypothalamus. However, it suggests that only a small proportion of AD patients might be interested in this approach and that the acceptance of DBS by AD patients was low, raising questions about the relevance of this approach to meet the expectations of these patients.


Assuntos
Doença de Alzheimer/complicações , Encéfalo/fisiologia , Estimulação Encefálica Profunda/métodos , Transtornos da Memória/etiologia , Transtornos da Memória/terapia , Adulto , Doença de Alzheimer/diagnóstico , Estudos de Viabilidade , Feminino , Fluordesoxiglucose F18 , Seguimentos , Humanos , Imageamento por Ressonância Magnética , Masculino , Transtornos da Memória/diagnóstico , Entrevista Psiquiátrica Padronizada , Pessoa de Meia-Idade , Testes Neuropsicológicos , Projetos Piloto , Tomografia por Emissão de Pósitrons , Fatores de Tempo , Adulto Jovem
2.
Nucl Med Commun ; 25(3): 271-6, 2004 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15094446

RESUMO

OBJECTIVES: Electrocardiographically gated blood pool SPECT (GBPS) is an interesting method for measuring left ventricular (LV) ejection fraction (LVEF) and volume. Recently, the availability of completely automatic GBPS processing software has been reported. We aimed to evaluate its reliability in measuring global LV systolic function. In addition, using the same population, we compared its reliability to that of three previously reported methods for processing GBPS. METHODS: We studied the performances of the new GBPS system for the evaluation of LVEFs and volumes in 29 patients. The LVEF provided by the planar equilibrium radionuclide angiography (planarLAO) and LV volumes provided by radiological LV contrast angiography (X-rays) were used as 'gold standards'. RESULTS: The new GBPS system failed in one patient. It shows good reproducibility for the measurement of both LVEF and volume. LVEF provided by this system is moderately correlated to planarLAO (r = 0.62; P < 0.001). The new GBPS constantly overestimates LVEF (P < 0.05). Results for LV volumes are moderately correlated to those obtained by X-ray investigation (r = 0.7; P < 0.001) but are significantly lower (P < 0.0001). There is a linear correlation between the average and the paired absolute difference for LV volumes (r = 0.52, P = 0.0001). CONCLUSIONS: The new, completely automatic, GBPS processing software is an interesting, moderately reliable method for measuring LVEF and volume. The performance of the method is lower than that previously reported for the same population for the other three GBPS processing methods.


Assuntos
Algoritmos , Eletrocardiografia/métodos , Imagem do Acúmulo Cardíaco de Comporta/métodos , Ventrículos do Coração/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Volume Cardíaco , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Software , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...