Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Pediatr Surg ; 2024 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-38981833

RESUMO

BACKGROUND: Children with Hirschsprung disease (HSCR) proximal to the splenic flexure or those needing a redo pull-through (PT) are at risk for tension and ischemia of the PT which could result in leak, stricture, or loss of ganglionated bowel. Colonic derotation is a technique used to minimize tension and avoid duodenal obstruction. The aim of this study was to describe this technique and outcomes in a series of patients requiring this intervention. METHODS: All patients underwent initial diversion and colonic mapping. The derotation procedure involves mobilization of the remaining colon, counterclockwise rotation via the stoma closure site, placement of the pull through (the right colon) lying on the right of the pelvis, and ligation of the middle colic artery with preservation of the marginal branch running from the ileocolic artery. This maneuver prevents compression of the duodenum by the mesenteric vessels and allows for an isoperistaltic, tension-free anastomosis. Intraoperative indocyanine green fluorescence angiography (ICG-FA) was utilized in many of the cases to map the blood supply of the pull-through colon. We reviewed outcomes for all children with HSCR who underwent colonic derotation from 2014 to 2023. Descriptive statistics were performed. RESULTS: There were 37 children included. Most were male (67.5%) with the original transition zone proximal to the rectosigmoid (81.1%). The median age at PT was 9.3 months [6.1-39.7]. Median operative time was 6.6 h [4.9-7.4] and 19 cases (51.4%) used ICG-FA. Most children had no 30-day postoperative complications (67.6%); in those who did develop complications, readmissions for electrolyte imbalance was most common (50.0%). There were zero cases of anastomotic leak at PT anastomosis. At long-term follow up, median 4.4 years [2.3-7.0], three children (8.1%) developed an anastomotic stricture, all were amenable to anal dilation, and five experienced episodes of enterocolitis (14.7%). Most children had between 1 and 4 stools per day (58.8%). CONCLUSION: Colonic derotation is a useful strategy to ensure well-perfused colonic length, protect the marginal artery blood supply, avoid duodenal compression, and ensure a tension-free anastomosis with minimal complications. TYPE OF STUDY: Original research, retrospective cohort. LEVEL OF EVIDENCE: III.

2.
Am J Infect Control ; 48(2): 227-229, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31515098

RESUMO

When implementing the latest innovations to reduce health care-associated infections, it is important not to overlook basic infection prevention principles such as hand hygiene, isolation precautions, use of personal protective equipment, and cleaning and low-level disinfection. Like many facilities, we implemented a multifaceted approach to reduce hospital-onset Clostridioides difficile infections. In this paper, we share simple tools that we found helpful in improving infection prevention practices by addressing knowledge gaps among staff, visitors, and patients.


Assuntos
Clostridioides difficile , Infecções por Clostridium/prevenção & controle , Pessoal de Saúde/educação , Controle de Infecções/métodos , Controle de Infecções/normas , Infecção Hospitalar/prevenção & controle , Fidelidade a Diretrizes , Humanos , Vigilância da População , Fatores de Tempo
3.
J Neurol Sci ; 339(1-2): 97-101, 2014 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-24553053

RESUMO

BACKGROUND: Embolic coils have been used to treat intracranial aneurysms using an endovascular approach for more than two decades. However, significant aneurysm recanalization rates have been reported specifically in large and giant aneurysms. Adding filaments to bare Platinum coils is considered a modification and has been proposed to achieve higher aneurysm occlusion rates as compared to bare Platinum coils. Quantitative information - in terms of thrombin generation potential of these modifications - is however lacking. OBJECTIVE: We report here in vitro thrombogenicity of Platinum coils containing Nylon (Axium™ MicroFx™ Nylon coil) and PGLA (Axium™ MicroFx™ PGLA coil) filaments and compare them with equivalent bare Platinum Axium™ coils. METHOD: We utilize a quantitative method that tracks the formation of thrombin upon exposure of the test samples to human platelet rich plasma using a slow binding fluorogenic substrate. RESULTS: We report a significant increase in the total thrombin turnover, the peak thrombin amount and the rate of thrombin generation for the Axium™ MicroFx™ coils and filaments compared to the Axium™ coils and Platinum wire. CONCLUSION: Nylon and PGLA filaments added to bare Platinum coils increase thrombogenicity of coils. This study offers a robust quantitative method to compare thrombus formation efficacy of embolic coils under static conditions.


Assuntos
Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/instrumentação , Platina/toxicidade , Polímeros/toxicidade , Trombose/etiologia , Desenho de Equipamento/instrumentação , Humanos , Aneurisma Intracraniano/terapia , Platina/administração & dosagem , Polímeros/administração & dosagem , Trombose/induzido quimicamente , Resultado do Tratamento
4.
Anesthesiology ; 110(5): 978-85, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19352154

RESUMO

BACKGROUND: Hand hygiene is a vital intervention to reduce health-care associated infections, but compliance remains low. The authors hypothesized that improvements in intraoperative hand hygiene compliance would reduce transmission of bacteria to surgical patients and reduce the incidence of postsurgical healthcare-associated infections. METHODS: The authors performed a controlled before-and-after study over 2 consecutive months. One hundred fourteen operative cases were enrolled. Two predesignated sites on the anesthesia machine were selected, decontaminated, and cultured via aseptic technique. These sites and the peripheral intravenous stopcock were cultured again after completion of the surgery. The treatment phase used a novel personal hand-decontamination device capable of recording hand-decontamination events. RESULTS: There were no significant differences in patient location, age, or case duration and procedure type between groups. Use of the Sprixx GJ device (Harbor Medical Inc., Santa Barbara, CA) increased hourly hand decontamination events by 27-fold as compared with baseline rates (P < 0.002; 95% confidence interval, 3.3-13.4). Use of the device was associated with a reduction in contamination in the anesthesia work area and peripheral intravenous tubing. Intravenous tubing contamination was identified in 32.8% of cases in the control group versus 7.5% in the treatment group (odds ratio, 0.17; 95% confidence interval, 0.06-0.51; P < 0.01). Healthcare-associated infections rates were reduced in the device group (3.8%) as compared with the control group (17.2%) (odds ratio, 0.19; 95% confidence interval, 0.00-0.81; P = 0.02). CONCLUSIONS: Improved hand hygiene compliance through the use of a novel hand sanitation strategy reduces the risk of intraoperative bacterial transmission. The intervention was associated with a reduction in healthcare-associated infections.


Assuntos
Infecção Hospitalar/prevenção & controle , Contaminação de Equipamentos/prevenção & controle , Desinfecção das Mãos/métodos , Controle de Infecções/instrumentação , Controle de Infecções/métodos , Complicações Intraoperatórias/prevenção & controle , Infecção Hospitalar/microbiologia , Feminino , Humanos , Infusões Intravenosas/efeitos adversos , Complicações Intraoperatórias/microbiologia , Masculino , Pessoa de Meia-Idade
5.
Anesthesiology ; 109(3): 399-407, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18719437

RESUMO

BACKGROUND: The current prevalence of hospital-acquired infections and evolving amplification of bacterial resistance are major public health concerns. A heightened awareness of intraoperative transmission of potentially pathogenic bacterial organisms may lead to implementation of effective preventative measures. METHODS: Sixty-one operative suites were randomly selected for analysis. Sterile intravenous stopcock sets and two sites on the anesthesia machine were decontaminated and cultured aseptically at baseline and at case completion. The primary outcome was the presence of a positive culture on the previously sterile patient stopcock set. Secondary outcomes were the number of colonies per surface area sampled on the anesthesia machine, species identification, and antibiotic susceptibility of isolated organisms. RESULTS: Bacterial contamination of the anesthesia work area increased significantly at the case conclusion, with a mean difference of 115 colonies per surface area sampled (95% confidence interval [CI], 62-169; P < 0.001). Transmission of bacterial organisms, including vancomycin-resistant enterococcus, to intravenous stopcock sets occurred in 32% (95% CI, 20.6-44.9%) of cases. Highly contaminated work areas increased the odds of stopcock contamination by 4.7 (95% CI, 1.42-15.42; P = 0.011). Contaminated intravenous tubing was associated with a trend toward increased nosocomial infection rates (odds ratio, 3.08; 95% CI, 0.56-17.5; P = 0.11) and with an increase in mortality (95% CI odds ratio, 1.11-infinity; P = 0.0395). CONCLUSION: Potentially pathogenic, multidrug-resistant bacterial organisms are transmitted during the practice of general anesthesia to both the anesthesia work area and intravenous stopcock sets. Implementation of infection control measures in this area may help to reduce both the evolving problem of increasing bacterial resistance and the development of life-threatening infectious complications.


Assuntos
Anestesia Geral/instrumentação , Bactérias/isolamento & purificação , Infecções Bacterianas/transmissão , Infecção Hospitalar/microbiologia , Contaminação de Equipamentos , Salas Cirúrgicas , Adulto , Idoso , Anestesia Geral/efeitos adversos , Anestesia Intravenosa/efeitos adversos , Anestesia Intravenosa/instrumentação , Contagem de Colônia Microbiana , Infecção Hospitalar/diagnóstico , Infecção Hospitalar/mortalidade , Eletroforese em Gel de Campo Pulsado , Contaminação de Equipamentos/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Projetos Piloto , Medição de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...