Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
J Appl Clin Med Phys ; 25(1): e14235, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38059633

RESUMO

PURPOSE: The purpose of this investigation was to assess the effect of visceral adipose tissue volume (VA) on reader efficacy in diagnosing and characterizing small bowel Crohn's disease using lower exposure CT enterography (CTE). Secondarily, we investigated the effect of lower exposure and VA on reader diagnostic confidence. METHODS: Prospective paired investigation of 256 CTE, 129 with Crohn's disease, were reconstructed at 100% and simulated 50% and 30% exposure. The senior author provided the disease classification for the 129 patients with Crohn's disease. Patient VA was measured, and exams were evaluated by six readers for presence or absence of Crohn's disease and phenotype using a 0-10-point scale. Logistic regression models assessed the effect of VA on sensitivity and specificity. RESULTS: The effect of VA on sensitivity was significantly reduced at 30% exposure (odds radio [OR]: 1.00) compared to 100% exposure (OR: 1.12) (p = 0.048). There was no statistically significant difference among the exposures with respect to the effect of visceral fat on specificity (p = 0.159). The study readers' probability of agreement with the senior author on disease classification was 60%, 56%, and 53% at 100%, 50%, and 30% exposure, respectively (p = 0.004). When detecting low severity Crohn's disease, readers' mean sensitivity was 83%, 75%, and 74% at 100%, 50%, and 30% exposure, respectively (p = 0.002). In low severity disease, sensitivity also tended to increase as visceral fat increased (ORs per 1000 cm3 increase in visceral fat: 1.32, 1.31, and 1.18, p = 0.010, 0.016, and 0.100, at 100%, 50%, and 30% exposure). CONCLUSIONS: While the interaction is complex, VA plays a role in detecting and characterizing small bowel Crohn's disease when exposure is altered, particularly in low severity disease.


Assuntos
Doença de Crohn , Enteropatias , Humanos , Doença de Crohn/diagnóstico por imagem , Gordura Intra-Abdominal/diagnóstico por imagem , Estudos Prospectivos , Tomografia Computadorizada por Raios X/métodos
2.
Abdom Radiol (NY) ; 48(9): 2956-2968, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36732408

RESUMO

Although much radiologic literature has focused on the short-term post-operative complications associated with ileal pouches, as the number of patients with long-term pouches has grown, there is increasing realization of the functional deficits that may occur long after pouch creation. Dynamic pouch imaging using fluoroscopy and MRI can provide assessment of the underlying causes of symptomatic pouch dysfunction and can provide critical insight to the management of this complex patient population. In this paper, we provide an overview of the unique problems encountered in patients with long-term ileal pouches, and provide an overview of the techniques, interpretation, and reporting for fluoroscopic and MR pouch defecography.


Assuntos
Bolsas Cólicas , Humanos , Bolsas Cólicas/efeitos adversos , Complicações Pós-Operatórias/diagnóstico por imagem , Imageamento por Ressonância Magnética , Fluoroscopia
3.
AJR Am J Roentgenol ; 219(6): 903-914, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35856454

RESUMO

Pancreatic ductal adenocarcinoma (PDAC) is one of the most aggressive malignancies, with a dismal survival rate. Screening the general population for early detection of PDAC is not recommended, but because early detection improves survival, high-risk individuals, defined as those meeting criteria based on a family history of PDAC and/or the presence of known pathogenic germline variant genes with PDAC risk, are recommended to undergo screening with MRI and/or endoscopic ultrasound at regular intervals. The Pancreatic Cancer Early Detection (PRECEDE) Consortium was formed in 2018 and is composed of gastroenterologists, geneticists, pancreatic surgeons, radiologists, statisticians, and researchers from 40 sites in North America, Europe, and Asia. The overarching goal of the PRECEDE Consortium is to facilitate earlier diagnosis of PDAC for high-risk individuals to increase survival of the disease. A standardized MRI protocol and reporting template are needed to enhance the quality of screening examinations, improve consistency of clinical management, and facilitate multiinstitutional research. We present a consensus statement to standardize MRI screening and reporting for individuals with elevated risk of pancreatic cancer.


Assuntos
Carcinoma Ductal Pancreático , Neoplasias Pancreáticas , Humanos , Detecção Precoce de Câncer , Carcinoma Ductal Pancreático/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/genética , Imageamento por Ressonância Magnética , Padrões de Referência , Neoplasias Pancreáticas
4.
Acad Radiol ; 29(1): 4-14, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-33162316

RESUMO

PURPOSE: To evaluate the effect of enema and dietary restrictions on prostate MR image quality metrics and to assess inter-reader agreement for these metrics. METHODS: This retrospective study included 195 men divided into groups based on their compliance with preparation instructions before prostate MRI (Enema + Diet, n = 98; Enema, n = 42; Diet, n = 35; Control [no compliance], n = 20). Four readers independently assessed six image quality metrics on a 5-point scale. Between-group comparisons were made using Wilcoxon rank sum test. Inter-reader agreement was calculated using Fleiss' kappa. RESULTS: Compared with the Control group, image quality with respect to rectal stool/gas, distortion of diffusion-weighted images, overall image quality, and confidence in assessment was higher in the Enema + Diet, Enema, and Diet groups (p  < 0.05 for all comparisons). The Enema + Diet and Enema groups had significantly higher scores than the Diet group for rectal stool/gas (p < 0.001 and 0.005, respectively). The Enema + Diet and Diet groups had higher scores than the Control group for rectal peristalsis (p = 0.027 and 0.009, respectively), but there were no significant differences in motion artifacts on T2-weighted images. Agreement among readers was fair, with kappa values ranging from 0.25 to 0.37. CONCLUSION: Enema and dietary restriction can improve the quality of prostate MRI by decreasing rectal distension and distortion of diffusion-weighted images and by increasing reader confidence in image assessment. Inter-reader agreement using subjective criteria for analysis of MRI quality is fair.


Assuntos
Próstata , Neoplasias da Próstata , Imagem de Difusão por Ressonância Magnética , Enema , Humanos , Imageamento por Ressonância Magnética , Masculino , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Estudos Retrospectivos
5.
J Am Coll Radiol ; 18(9): 1324-1331, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34004175

RESUMO

OBJECTIVE: To assess current practice patterns with respect to protocols used for incidental pancreatic cyst follow-up, management guidelines, and template reporting. METHODS: The Society of Abdominal Radiology Disease Focused Panel on intraductal pancreatic neoplasms distributed an anonymous 14-question survey to its members in June 2018 that focused on current utilization of incidental pancreatic cyst guidelines, protocols, and template reporting. RESULTS: Among the 1,390 email invitations, 323 responded, and 94.7% (306 of 323) completed all questions. Respondents were mainly radiologists (93.8%, 303 of 323) from academic institutions (74.7%, 227 of 304) in North America (93.7%, 286 of 305). Of respondents, 42.5% (136 of 320) preferred 2017 ACR recommendations, 17.8% (57 of 320) homegrown systems, 15.0% (48 of 320) Fukuoka guidelines, and 7.8% (25 of 320) American Gastroenterological Association guidelines. The majority (68.7%, 222 of 323) agreed or strongly agreed that developing a single international consensus recommendation for management was important, and most radiologists preferred to include them in reports (231 of 322, 71.7%); yet only half included recommendations in >75% of reports (161 of 321). MR cholangiopancreatography was the modality of choice for follow-up of <2.5 cm cysts. Intravenous contrast was routinely used by 69.7% (212 of 304). Standardized reporting templates were rarely used in practice (12.8% 39 of 306). CONCLUSIONS: Nearly 7 of 10 radiologists desire a unified international consensus recommendation for management of incidental cystic pancreatic lesions; ACR 2017 recommendations are most commonly used, followed by homegrown systems and Fukuoka guidelines. The majority of radiologists routinely use MR cholangiopancreatography with intravenous contrast for follow-up of incidental cystic lesions, but template reporting is rarely used.


Assuntos
Cisto Pancreático , Neoplasias Pancreáticas , Radiologia , Humanos , Achados Incidentais , Cisto Pancreático/diagnóstico por imagem , Cisto Pancreático/terapia , Radiografia Abdominal , Inquéritos e Questionários
6.
AJR Am J Roentgenol ; 217(2): 347-358, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-32936014

RESUMO

Ileal pouch-anal anastomosis (IPAA) surgery is the reference standard surgical procedure for treatment of ulcerative colitis and most patients with familial adenomatous polyposis. This procedure allows preservation of fecal continence and gastrointestinal continuity. However, it is associated with a wide variety of complications, which often have nonspecific and overlapping clinical presentations, making imaging an important part of workup for pouch dysfunction. The purpose of this article is to propose structured reporting templates for MRI and water-soluble contrast enema (WSCE), based on our referral pouch center's experience, in patients who have undergone IPAA surgery. We review salient surgical technique, pouch anatomy, and imaging protocols, with an emphasis on a systematic search pattern for evaluation of ileal pouch complications using proposed structured reporting templates for MRI and WSCE.


Assuntos
Meios de Contraste , Enema/métodos , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Complicações Pós-Operatórias/diagnóstico por imagem , Proctocolectomia Restauradora , Colo/diagnóstico por imagem , Humanos , Reto/diagnóstico por imagem , Encaminhamento e Consulta
7.
Abdom Radiol (NY) ; 46(4): 1586-1606, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33185741

RESUMO

There have been many publications detailing imaging features of malignant transformation of intraductal papillary mucinous neoplasms (IPMN), management and recommendations for imaging follow-up of diagnosed or presumed IPMN. However, there is no consensus on several practical aspects of imaging IPMN that could serve as a clinical guide for radiologists and enable future data mining for research. These aspects include how to measure IPMN, define reporting terminology, standardize reporting and unify guidelines for surveillance. The Society of Abdominal Radiology (SAR) created multiple Disease-Focused Panels (DFP) comprised multidisciplinary panel members who focus on a particular disease, with the goal to develop ways for radiologists to improve patient care, education, and research. DFP members met to identify the current controversies and limitations of imaging pancreatic IPMN. This paper aims to provide a practical review of the key imaging characteristics of IPMN for trainees and practicing radiologists, to guide uniformity of performance and interpretation of surveillance imaging studies, and to improve communication with clinicians by providing a lexicon and reporting template based on the experience of the SAR-DFP panel members.


Assuntos
Neoplasias Intraductais Pancreáticas , Neoplasias Pancreáticas , Radiologia , Humanos , Pâncreas , Neoplasias Intraductais Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico por imagem , Radiografia Abdominal
8.
Can Assoc Radiol J ; 70(4): 416-423, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31604596

RESUMO

PURPOSE: To evaluate whole-lesion 3D-histogram apparent diffusion coefficient (ADC) metrics for assessment of pancreatic malignancy. METHODS: Forty-two pancreatic malignancies (36 pancreatic adenocarcinoma [PDAC], 6 pancreatic neuroendocrine [PanNET]) underwent abdominal magnetic resonance imaging (MRI) with diffusion-weighted imaging before endoscopic ultrasound biopsy or surgical resection. Two radiologists independently placed 3D volumes of interest to derive whole-lesion histogram ADC metrics. Mann-Whitney tests and receiver operating characteristic analyses were used to assess metrics' diagnostic performance for lesion histology, T-stage, N-stage, and grade. RESULTS: Whole-lesion ADC histogram metrics lower in PDACs than PanNETs for both readers (P ≤ .026) were mean ADC (area under the curve [AUC] = 0.787-0.792), mean of the bottom 10th percentile (mean0-10) (AUC = 0.787-0.880), mean of the 10th-25th percentile (mean10-25) (AUC = 0.884-0.917) and mean of the 25th-50th percentile (mean25-50) (AUC = 0.829-0.829). For mean10-25 (metric with highest AUC for identifying PDAC), for reader 1 a threshold > 0.94 × 10-3 mm2/s achieved sensitivity 94% and specificity 83%, and for reader 2 a threshold > 0.82 achieved sensitivity 97% and specificity 67%. Metrics lower in nodal status ≥ N1 than N0 for both readers (P ≤ .043) were mean0-10 (AUC = 0.789-0.822) and mean10-25 (AUC = 0.800-0.822). For mean10-25 (metric with highest AUC for identifying N0), for reader 1 a threshold <1.17 achieved sensitivity 87% and specificity 67%, and for reader 2 a threshold <1.04 achieved sensitivity 87% and specificity 83%. No metric was associated with T-stage (P > .195) or grade (P > .215). CONCLUSION: Volumetric ADC histogram metrics may serve as non-invasive biomarkers of pancreatic malignancy. Mean10-25 outperformed standard mean for lesion histology and nodal status, supporting the role of histogram analysis.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias Pancreáticas/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Biópsia Guiada por Imagem , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Neoplasias Pancreáticas/patologia
9.
AJR Am J Roentgenol ; 210(1): 113-117, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29045185

RESUMO

OBJECTIVE: The purpose of this study was to compare the reproducibility and diagnostic performance of 2D and 3D ROIs for prostate apparent diffusion coefficient (ADC) measurements. MATERIALS AND METHODS: The study included 56 patients with prostate cancer undergoing 3-T MRI including DWI (b = 50 and 1000 s/mm2) before radical prostatectomy. Histologic findings from prostatectomy specimens were reviewed to denote each patient's dominant tumor and a benign region with visually decreased ADC. Three readers independently measured the ADCs of both areas using an ROI placed on a single slice through the lesion (2D) and an ROI encompassing all slices through the lesion (3D). Readers repeated measurements after 3 weeks. Assessment included Bland-Altman analysis (coefficient of repeatability [CR] in which lower values indicated higher reliability) and ROC analysis. RESULTS: For intrareader variability, the CRs across readers for all ROIs were 9.9% for 2D and 9.3% for 3D. For tumor ROIs the CRs were 10.6% for 2D and 9.6% for 3D. For interreader variability, the CRs across readers for all ROIs were 17.1% for 2D and 20.5% for 3D and for tumor ROIs were 17.9% for 2D and 22.2% for 3D. For combined reader data, the AUCs for benign and malignant findings were 0.77 for 2D and 0.78 for 3D (p = 0.146). For differentiating Gleason score (GS) 3 + 3 from GS > 3 + 3 tumors, the AUCs were 0.92 for 2D and 0.92 for 3D ROIs (p = 0.649). For differentiating GS ≤ 3 + 4 from GS ≥ 4 + 3 tumors, the AUCs were 0.70 for 2D and 0.67 for 3D ROIs (p = 0.004). CONCLUSION: Use of a 3D ROI did not improve intrareader or interreader reproducibility or diagnostic performance compared with use of a 2D ROI for prostate ADC measurements. Interreader reproducibility of 2D ROIs was suboptimal nonetheless.


Assuntos
Imagem de Difusão por Ressonância Magnética , Neoplasias da Próstata/diagnóstico por imagem , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Prostatectomia , Neoplasias da Próstata/patologia , Neoplasias da Próstata/cirurgia , Curva ROC , Reprodutibilidade dos Testes , Estudos Retrospectivos
10.
J Comput Assist Tomogr ; 41(6): 949-956, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28806322

RESUMO

OBJECTIVE: The purpose of this study was to compare image quality and tumor assessment at prostate magnetic resonance imaging (MRI) between reduced field-of-view diffusion-weighted imaging (rFOV-DWI) and standard DWI (st-DWI). METHODS: A total of 49 patients undergoing prostate MRI and MRI/ultrasound fusion-targeted biopsy were included. Examinations included st-DWI (field of view [FOV], 200 × 200 mm) and rFOV-DWI (FOV, 140 × 64 mm) using a 2-dimensional (2D) spatially-selective radiofrequency pulse and parallel transmission. Two readers performed qualitative assessments; a third reader performed quantitative evaluation. RESULTS: Overall image quality, anatomic distortion, visualization of capsule, and visualization of peripheral/transition zone edge were better for rFOV-DWI for reader 1 (P ≤ 0.002), although not for reader 2 (P ≥ 0.567). For both readers, sensitivity, specificity, and accuracy for tumor with a Gleason Score (GS) of 3 + 4 or higher were not different (P ≥ 0.289). Lesion clarity was higher for st-DWI for reader 2 (P = 0.008), although similar for reader 1 (P = 0.409). Diagnostic confidence was not different for either reader (P ≥ 0.052). Tumor-to-benign apparent diffusion coefficient ratio was not different (P = 0.675). CONCLUSIONS: Potentially improved image quality of rFOV-DWI did not yield improved tumor assessment. Continued optimization is warranted.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Imagem Ecoplanar , Neoplasias da Próstata/diagnóstico por imagem , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
11.
Acad Radiol ; 24(5): 603-608, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28169142

RESUMO

RATIONALE AND OBJECTIVES: To assess the American College of Radiology Incidental Findings Committee's (ACR-IFC) recommendations for defining and following up abnormal incidental abdominopelvic lymph nodes. MATERIALS AND METHODS: A total of 59 lymph nodes satisfying ACR-IFC criteria as incidental (no malignancy or lymphoproliferative disorder) and with sufficient follow-up to classify as benign (biopsy, decreased size, ≥12-month stability) or malignant (biopsy, detection of primary malignancy combined with either fluorodeoxyglucose hyperactivity or increase in size of the node) were included. Two radiologists independently assessed nodes for suspicious features by ACR-IFC criteria (round with indistinct hilum, hypervascularity, necrosis, cluster ≥3 nodes, cluster ≥2 nodes in ≥2 stations, size ≥1 cm in retroperitoneum). Outcomes were assessed with attention to ACR-IFC's recommendation for initial 3-month follow-up. RESULTS: A total of 8.5% of nodes were malignant; 91.5% were benign. Two of six malignant nodes were stable at 3 to <6-month follow-up before diagnosis; diagnosis of four of five malignant nodes was facilitated by later development of non-nodal sites of tumor. A total of 13, 5, 8, and 9 nodes were deemed benign given a decrease at <3 months, 3-5 months, 6-11 months, or ≥12 months of follow-up. No ACR-IFC feature differentiated benign and malignant nodes (P = 0.164-1.0). A cluster ≥3 nodes was present in 88.1%-93.2% of nodes. A total of 96.6%-98.3% had ≥1 suspicious feature for both readers. Necrosis and hypervascularity were not identified in any node. CONCLUSIONS: ACR-IFC imaging features overwhelmingly classified incidental nodes as abnormal, although did not differentiate benign and malignant nodes. Nodes stable at the ACR-IFC's advised initial 3-month follow-up were occasionally proven malignant or decreased on further imaging. Refinement of imaging criteria to define nodes of particularly high risk, integrated with other clinical criteria, may help optimize the follow-up of incidental abdominopelvic lymph nodes.


Assuntos
Neoplasias Abdominais/secundário , Gerenciamento Clínico , Achados Incidentais , Linfonodos/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/normas , Guias de Prática Clínica como Assunto , Tomografia Computadorizada por Raios X/normas , Neoplasias Abdominais/diagnóstico , Neoplasias Abdominais/terapia , Feminino , Seguimentos , Humanos , Biópsia Guiada por Imagem/normas , Metástase Linfática/diagnóstico , Masculino , Pessoa de Meia-Idade , Radiologia , Estados Unidos
12.
Clin Imaging ; 42: 172-177, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28068586

RESUMO

PURPOSE: To evaluate whole-pancreas 3D-histogram ADC metrics in acute pancreatitis. METHODS: In 41 patients with acute pancreatitis undergoing MRI/MRCP with DWI, 3D-volumes-of-interest encompassing the entire pancreas were placed to derive whole-pancreas histogram ADC metrics. RESULTS: There were trends toward higher 0-10th percentile ADC, higher 10-25th percentile ADC, lower skewness, and higher kurtosis in patients with new complications (p=0.065-0.095). Conventional mean ADC showed no association with new complications (p=0.203). Kurtosis had highest area-under-the-curve (0.784) for predicting new complications (sensitivity=75.0%; specificity=91.9%). CONCLUSION: Findings suggest whole-pancreas histogram ADC metrics assist early management of acute pancreatitis, (e.g., patient selection for more intensive monitoring/intervention).


Assuntos
Imagem de Difusão por Ressonância Magnética , Interpretação de Imagem Assistida por Computador , Pâncreas/diagnóstico por imagem , Pancreatite/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Progressão da Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade , Adulto Jovem
13.
Abdom Radiol (NY) ; 42(1): 290-297, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27576605

RESUMO

PURPOSE: To compare image quality and diagnostic performance for detecting local recurrence (LR) of prostate cancer after radical prostatectomy (RP) between standard dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) and a high spatiotemporal resolution, continuously acquired Golden-angle RAdial Sparse Parallel acquisition employing compressed sensing reconstruction ("GRASP"). METHODS: A search was conducted for prostate MRI examinations performed in patients with PSA ≥0.2 ng/mL after RP in whom follow-up evaluation allowed classification as positive (≥50% PSA reduction after pelvic radiation or positive biopsy) or negative (<50% PSA reduction after pelvic radiation; spontaneous PSA normalization) for LR, yielding 13 patients with standard DCE (11 LR+) and 12 with GRASP (10 LR+). Standard DCE had voxel size 3.0 × 1.9 × 1.9 mm and temporal resolution 5.5 s. GRASP had voxel size 1.0 × 1.1 × 1.1 cm and was retrospectively reconstructed at 2.3 s resolution. Two radiologists evaluated DCE sequences for image quality measures (1-5 scale) and the presence of LR. RESULTS: GRASP achieved higher scores than standard DCE from both readers (p < 0.001-0.136) for anatomic clarity (R1: 4.4 ± 0.8 vs. 2.8 ± 0.67 R2: 4.8 ± 0.5 vs. 3.2 ± 0.6), sharpness (3.6 ± 0.9 vs. 2.5 ± 0.7; 4.6 ± 0.5 vs. 2.6 ± 0.5), confidence in interpretation (3.8 ± 0.8 vs. 3.1 ± 0.9; 3.8 ± 1.0 vs. 3.1 ± 1.2), and conspicuity of detected lesions (4.7 ± 0.5 vs. 3.8 ± 1.1; 4.5 ± 0.5 vs. 3.8 ± 1.0). For detecting LR, GRASP also achieved higher sensitivity (70% vs. 36%; 80% vs. 45%), specificity (R1 and R2: 100% vs. 50%), and accuracy (75% vs. 38%; 83% vs. 46%) for both readers. CONCLUSION: Although requiring larger studies, high spatiotemporal resolution GRASP achieved substantially better image quality and diagnostic performance than standard DCE for detecting LR in patients with elevated PSA after prostatectomy.


Assuntos
Imageamento por Ressonância Magnética/métodos , Recidiva Local de Neoplasia/diagnóstico por imagem , Recidiva Local de Neoplasia/patologia , Prostatectomia/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Neoplasias da Próstata/cirurgia , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
14.
Radiology ; 283(1): 119-129, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-27783538

RESUMO

Purpose To test the impact of existing Prostate Imaging Reporting and Data System (PI-RADS) version 2 (V2) decision rules, as well as of proposed adjustments to these decision rules, on detection of Gleason score (GS) 7 or greater (GS ≥7) prostate cancer. Materials and Methods Two radiologists independently provided PI-RADS V2 scores for the dominant lesion on 343 prostate magnetic resonance (MR) examinations. Diagnostic performance for GS ≥7 tumor was assessed by using MR imaging-ultrasonography fusion-targeted biopsy as the reference. The impact of existing PI-RADS V2 decision rules, as well as a series of exploratory proposed adjustments, on the frequency of GS ≥7 tumor detection, was evaluated. Results A total of 210 lesions were benign, 43 were GS 6, and 90 were GS ≥7. Lesions were GS ≥7 in 0%-4.1% of PI-RADS categories 1 and 2, 11.4%-27.1% of PI-RADS category 3, 44.4%-49.3% of PI-RADS category 4, and 72.1%-73.7% of PI-RADS category 5 lesions. PI-RADS category 4 or greater had sensitivity of 78.9%-87.8% and specificity of 75.5%-79.1 for detecting GS ≥7 tumor. The frequency of GS ≥7 tumor for existing PI-RADS V2 decision rules was 30.0%-33.3% in peripheral zone (PZ) lesions upgraded from category 3 to 4 based on dynamic contrast enhancement (DCE) score of positive; 50.0%-66.7% in transition zone (TZ) lesions upgraded from category 3 to 4 based on diffusion-weighted imaging (DWI) score of 5; and 71.7%-72.7% of lesions in both zones upgraded from category 4 to 5 based on size of 15 mm or greater. The frequency of GS ≥7 tumor for proposed adjustments to the decision rules was 30.0%-60.0% for TZ lesions upgraded from category 3 to 4 based on DWI score of 4; 33.3%-57.1% for TZ lesions upgraded from category 3 to 4 based on DCE score of positive when incorporating new criteria (unencapsulated sheetlike enhancement) for DCE score of positive in TZ; and 56.4%-61.9% for lesions in both zones upgraded from category 4 to 5 based on size of 10-14 mm. Other proposed adjustments yielded GS ≥7 tumor in less than 15% of cases for one or more readers. Conclusion Existing PI-RADS V2 decision rules exhibited reasonable performance in detecting GS ≥7 tumor. Several proposed adjustments to the criteria (in TZ, upgrading category 3 to 4 based on DWI score of 4 or modified DCE score of positive; in PZ or TZ, upgrading category 4 to 5 based on size of 10-14 mm) may also have value for this purpose. © RSNA, 2016 Online supplemental material is available for this article.


Assuntos
Tomada de Decisão Clínica/métodos , Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/diagnóstico por imagem , Sistemas de Informação em Radiologia , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Próstata/diagnóstico por imagem , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
15.
J Magn Reson Imaging ; 45(5): 1464-1475, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-27649481

RESUMO

PURPOSE: To assess the effects of temporal resolution (RT ) in dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) on qualitative tumor detection and quantitative pharmacokinetic parameters in prostate cancer. MATERIALS AND METHODS: This retrospective Institutional Review Board (IRB)-approved study included 58 men (64 ± 7 years). They underwent 3T prostate MRI showing dominant peripheral zone (PZ) tumors (24 with Gleason ≥ 4 + 3), prior to prostatectomy. Continuously acquired DCE utilizing GRASP (Golden-angle RAdial Sparse Parallel) was retrospectively reconstructed at RT of 1.4 sec, 3.7 sec, 6.0 sec, 9.7 sec, and 14.9 sec. A reader placed volumes-of-interest on dominant tumors and benign PZ, generating quantitative pharmacokinetic parameters (ktrans , ve ) at each RT . Two blinded readers assessed each RT for lesion presence, location, conspicuity, and reader confidence on a 5-point scale. Data were assessed by mixed-model analysis of variance (ANOVA), generalized estimating equation (GEE), and receiver operating characteristic (ROC) analysis. RESULTS: RT did not affect sensitivity (R1all : 69.0%-72.4%, all Padj = 1.000; R1GS≥4 + 3 : 83.3-91.7%, all Padj = 1.000; R2all : 60.3-69.0%, all Padj = 1.000; R2GS≥4 + 3 : 58.3%-79.2%, all Padj = 1.000). R1 reported greater conspicuity of GS ≥ 4 + 3 tumors at RT of 1.4 sec vs. 14.9 sec (4.29 ± 1.23 vs. 3.46 ± 1.44; Padj = 0.029). No other tumor conspicuity pairwise comparison reached significance (R1all : 2.98-3.43, all Padj ≥ 0.205; R2all : 2.57-3.19, all Padj ≥ 0.059; R1GS≥4 + 3 : 3.46-4.29, all other Padj ≥ 0.156; R2GS≥4 + 3 : 2.92-3.71, all Padj ≥ 0.439). There was no effect of RT on reader confidence (R1all : 3.17-3.34, all Padj = 1.000; R2all : 2.83-3.19, all Padj ≥ 0.801; R1GS≥4 + 3 : 3.79-4.21, all Padj = 1.000; R2GS≥4 + 3 : 3.13-3.79, all Padj = 1.000). ktrans and ve of tumor and benign tissue did not differ across RT (all adjusted P values [Padj ] = 1.000). RT did not significantly affect area under the curve (AUC) of Ktrans or ve for differentiating tumor from benign (all Padj = 1.000). CONCLUSION: Current PI-RADS recommendations for RT of 10 seconds may be sufficient, with further reduction to the stated PI-RADS preference of RT ≤ 7 seconds offering no benefit in tumor detection or quantitative analysis. LEVEL OF EVIDENCE: 3 J. MAGN. RESON. IMAGING 2017;45:1464-1475.


Assuntos
Meios de Contraste/farmacocinética , Imageamento por Ressonância Magnética , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Humanos , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Fatores de Tempo
16.
Abdom Radiol (NY) ; 42(4): 1222-1228, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-27900458

RESUMO

PURPOSE: To evaluate whole-lesion ADC histogram metrics for assessing the malignant potential of pancreatic intraductal papillary mucinous neoplasms (IPMNs), including in comparison with conventional MRI features. METHODS: Eighteen branch-duct IPMNs underwent MRI with DWI prior to resection (n = 16) or FNA (n = 2). A blinded radiologist placed 3D volumes-of-interest on the entire IPMN on the ADC map, from which whole-lesion histogram metrics were generated. The reader also assessed IPMN size, mural nodularity, and adjacent main-duct dilation. Benign (low-to-intermediate grade dysplasia; n = 10) and malignant (high-grade dysplasia or invasive adenocarcinoma; n = 8) IPMNs were compared. RESULTS: Whole-lesion ADC histogram metrics demonstrating significant differences between benign and malignant IPMNs were: entropy (5.1 ± 0.2 vs. 5.4 ± 0.2; p = 0.01, AUC = 86%); mean of the bottom 10th percentile (2.2 ± 0.4 vs. 1.6 ± 0.7; p = 0.03; AUC = 81%); and mean of the 10-25th percentile (2.8 ± 0.4 vs. 2.3 ± 0.6; p = 0.04; AUC = 79%). The overall mean ADC, skewness, and kurtosis were not significantly different between groups (p ≥ 0.06; AUC = 50-78%). For entropy (highest performing histogram metric), an optimal threshold of >5.3 achieved a sensitivity of 100%, a specificity of 70%, and an accuracy of 83% for predicting malignancy. No significant difference (p = 0.18-0.64) was observed between benign and malignant IPMNs for cyst size ≥3 cm, adjacent main-duct dilatation, or mural nodule. At multivariable analysis of entropy in combination with all other ADC histogram and conventional MRI features, entropy was the only significant independent predictor of malignancy (p = 0.004). CONCLUSION: Although requiring larger studies, ADC entropy obtained from 3D whole-lesion histogram analysis may serve as a biomarker for identifying the malignant potential of IPMNs, independent of conventional MRI features.


Assuntos
Adenocarcinoma Mucinoso/diagnóstico por imagem , Adenocarcinoma Mucinoso/patologia , Carcinoma Ductal Pancreático/diagnóstico por imagem , Carcinoma Ductal Pancreático/patologia , Carcinoma Papilar/diagnóstico por imagem , Carcinoma Papilar/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/patologia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
17.
Clin Imaging ; 40(3): 352-6, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27133666

RESUMO

PURPOSE: To compare MRI features of pathologically-proven hepatocellular carcinoma (HCC) between patients with hepatitis B (HBV) and hepatitis C (HCV) infection. METHODS: Two radiologists assessed 51 confirmed HCCs on MRI in HBV (n=18) or HCV (n=33) patients; a third, more experienced, radiologist resolved discrepancies. RESULTS: Arterial hyperenhancement occurred more frequently in HCV (90.9% vs. 66.7%; P=.032), DWI/T2WI hyperintensity more frequently in HBV [(DWI: 78.6% vs. 45.8%, T2WI: 77.8% vs. 48.5%; P=.073-0.088)]. Tumors were larger in HBV (P≤.016). Washout, pseudocapsule, homogeneity, circumscribed margins, lipid, iron, and visually low ADC were not different. CONCLUSION: Larger studies are required to confirm these preliminary findings.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Hepatite B Crônica/complicações , Hepatite C Crônica/complicações , Neoplasias Hepáticas/diagnóstico por imagem , Imageamento por Ressonância Magnética , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/virologia , Feminino , Humanos , Neoplasias Hepáticas/virologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
18.
Abdom Radiol (NY) ; 41(5): 919-25, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-27193790

RESUMO

PURPOSE: The purpose of this study was to assess the feasibility of zoomed echo-planar imaging (EPI) diffusion tensor imaging (DTI) with 2-channel parallel transmission (pTx) for MR tractography of the periprostatic neurovascular bundle (NVB) without an endorectal coil, and to compare its performance to that of conventionally acquired DTI. METHODS: 8 healthy males (28.9 ± 4.6 years) underwent pelvic phased-array coil prostate MRI on a 3T system using both zoomed-EPI DTI (z-DTI) with 2-channel pTx and conventional single-shot spin-echo EPI DTI (c-DTI) acquisitions with 6 encoding directions and b-values of 0 and 1000 s/mm(2). Fractional anisotropy (FA) maps and tractography analysis incorporating 3D visualization of the NVB were performed from each acquisition. Fiber tract counts, estimated signal-to-noise ratio (eSNR), and image quality measures of the FA maps and NVB tractography were compared. Quantitative and image quality measures were compared using Wilcoxon signed rank tests. RESULTS: 3 of 8 subjects had no tracts detected with c-DTI acquisition, while all 8 had tracts detected with z-DTI. z-DTI acquisition yielded significantly more fiber tracts (c-DTI: 77 ± 116 tracts; z-DTI: 430 ± 228 tracts; p = 0.019) and higher eSNR (c-DTI: 2.9 ± 1.2; z-DTI: 13.17 ± 9.9; p = 0.014). Relative to c-DTI acquisitions, z-DTI FA maps showed significantly reduced artifact (p = 0.008) and reduced anatomic distortion of the prostate (p = 0.010), while z-DTI tractography showed significantly better overall visual quality (p = 0.011), tract symmetry (p = 0.010), tract coherence (p = 0.011), and subjective similarity to the actual NVB (p = 0.011). CONCLUSION: Zoomed-EPI DTI acquisition for tractography of the prostate gland NVB improves quantitative and qualitative measures of image and tract fiber quality, allowing tractography of the NVB at 3T without using an endorectal coil.


Assuntos
Imagem de Tensor de Difusão , Imagem Ecoplanar , Próstata/inervação , Adulto , Algoritmos , Anisotropia , Estudos de Viabilidade , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Masculino , Fibras Nervosas Mielinizadas , Próstata/irrigação sanguínea , Prostatectomia , Razão Sinal-Ruído
19.
Acad Radiol ; 23(6): 704-11, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26992738

RESUMO

RATIONALE AND OBJECTIVES: The aim of this study was to assess prostate cancer detection using a broad range of computed b-values up to 5000 s/mm(2). MATERIALS AND METHODS: This retrospective Health Insurance Portability and Accountability Act-compliant study was approved by an institutional review board with consent waiver. Forty-nine patients (63 ± 8 years) underwent 3T prostate magnetic resonance imaging before prostatectomy. Examinations included diffusion-weighted imaging (DWI) with b-values of 50 and 1000 s/mm(2). Seven computed DWI image sets (b-values: 1000, 1500, 2000, 2500, 3000, 4000, and 5000 s/mm(2)) were generated by mono-exponential fit. Two blinded radiologists (R1 [attending], R2 [fellow]) independently evaluated diffusion weighted image sets for image quality and dominant lesion location. A separate unblinded radiologist placed regions of interest to measure tumor-to-peripheral zone (PZ) contrast. Pathologic findings from prostatectomy served as reference standard. Measures were compared between b-values using the Jonckheere-Terpstra trend test, Spearman correlation coefficient, and generalized estimating equations based on logistic regression for correlated data. RESULTS: As b-value increased, tumor-to-PZ contrast and benign prostate suppression for both readers increased (r = +0.65 to +0.71, P ≤ 0.001), whereas anatomic clarity, visualization of the capsule, and visualization of peripheral-transition zone edge decreased (r = -0.69 to -0.75, P ≤ 0.003). Sensitivity for tumor was highest for R1 at b1500-3000 (84%-88%) and for R2 at b1500-2500 (70%-76%). Sensitivities for both pathologic outcomes were lower for both readers at both b1000 and the highest computed b-values. Sensitivity for Gleason >6 tumor was highest for R1 at b1500-3000 (90%-93%) and for R2 at 1500-2500 (78%-80%). The positive predictive value for tumor for R1 was similar from b1000 to 4000 (93%-98%) and for R2 was similar from b1500 to 4000 (88%-94%). CONCLUSIONS: Computed b-values in the range of 1500-2500 s/mm(2) (but not higher) were optimal for prostate cancer detection; b-values of 1000 or 3000-5000 exhibited overall lower performance.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias da Próstata/diagnóstico por imagem , Idoso , Humanos , Aumento da Imagem , Masculino , Pessoa de Meia-Idade , Prostatectomia , Neoplasias da Próstata/patologia , Neoplasias da Próstata/cirurgia , Estudos Retrospectivos , Sensibilidade e Especificidade
20.
Abdom Radiol (NY) ; 41(1): 63-70, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26830613

RESUMO

PURPOSE: To explore whole-lesion histogram analysis of the hepatobiliary phase (HBP) defect in indeterminate hypovascular liver lesions for predicting progression to arterial-enhancing hepatocellular carcinoma (HCC). METHODS: Twenty patients undergoing gadoxetic acid-enhanced MRI for HCC screening with 12° and 25° flip angle (FA) HBP acquisitions demonstrating an indeterminate lesion showing HBP hypointensity but no arterial enhancement were included. Volumes-of-interest were placed on HBP defects, from which histogram metrics were obtained. Associations between these metrics and progression to arterial-enhancing HCC on follow-up imaging were investigated. Lesions were also assessed for the presence of a signal abnormality on conventional sequences. RESULTS: 40% of lesions progressed to arterial-enhancing HCC; 60% were stable at ≥6 months follow-up. Neither T2-hyperintensity increased diffusion signal nor portal/equilibrium phase washout was different between progressing and nonprogressing lesions (p = 1.0). Among direct signal intensity-based measures (overall mean; mean of bottom 10th, 10-25th, and 25-50th percentiles), area-under-the-curve (AUC) for prediction of progression to arterial-enhancing HCC was consistently higher at 25° (range 0.619-0.657) than at 12° (range 0.512-0.548). However, at both FAs, the four measures with highest AUC were measures related to lesion texture and heterogeneity [standard deviation (SD), coefficient of variation (CV), skewness, and entropy], having AUC of 0.655-0.750 at 12° and 0.686-0.800 at 25. The metric with highest AUC at 12° was SD (AUC = 0.750) and at 25° was CV (AUC = 0.800). CONCLUSION: Whole-lesion histogram HBP measures of indeterminate hypovascular liver lesions may help predict progression to arterial-enhancing HCC by reflecting greater lesion heterogeneity, particularly at higher FA. Larger studies are therefore warranted.


Assuntos
Carcinoma Hepatocelular/patologia , Neoplasias Hepáticas/patologia , Imageamento por Ressonância Magnética/métodos , Neovascularização Patológica/patologia , Lesões Pré-Cancerosas/irrigação sanguínea , Lesões Pré-Cancerosas/patologia , Meios de Contraste/administração & dosagem , Progressão da Doença , Feminino , Gadolínio DTPA/administração & dosagem , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Reprodutibilidade dos Testes , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...