1.
Rev Sci Instrum ; 94(1): 013501, 2023 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-36725552

RESUMO

The only method for assessing the fusion power throughput of a deuterium-tritium (DT) reactor presently relies on determining the absolute number of 14 MeV neutrons produced in the DT plasma. An independent method, developed and investigated during the recent DT campaign at the Joint European Torus, is based on the absolute counting of 17 MeV gamma rays produced by the competing T(D, γ)5He reaction that features a very weak branching ratio (about 3-6 × 10-6) when compared to the main T(D, n)4He reaction. The state-of-the-art spectrometer used for gamma-ray measurements in magnetic confinement fusion plasmas is LaBr3(Ce) scintillator detectors, although they require significant neutron shielding to extract a relatively weak gamma-ray signal from a much more abundant neutron field. A better approach relies on a gamma-ray detector that is intrinsically insensitive to neutrons. We have advanced the design of a gamma-ray counter based on the Cherenkov effect for gamma-rays whose energy exceeds 11 MeV, optimized to work in the neutron-rich environment of a steady-state, magnetically confined fusion plasma device. The gamma-rays interact with an aluminum window and extract electrons that move into the radiator emitting photons via the Cherenkov effect. Since the Cherenkov light consists of few photons (25 on average) in the far UV band (100-200 nm), a pre-amplifier is required to transport the photons to the neutron-shielded location, which may be a few meters away, where the readout elements of the detector, either a silicon or standard photomultiplier tube, are placed. The present work focuses on the development of a scintillating GEM (Gas Electron Multiplier) based pre-amplifier that acts as a Cherenkov photon pre-amplifier and wavelength shifter. This paper presents the result of a set of Garfield++ simulations developed to find the optimal GEM working parameters. A photon gain of 100 is obtained by biasing a single GEM foil to 1 kV.

2.
Rev Sci Instrum ; 93(11): 113512, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36461481

RESUMO

Dedicated nuclear diagnostics have been designed, developed, and built within EUROFUSION enhancement programs in the last ten years for installation at the Joint European Torus and capable of operation in high power Deuterium-Tritium (DT) plasmas. The recent DT Experiment campaign, called DTE2, has been successfully carried out in the second half of 2021 and provides a unique opportunity to evaluate the performance of the new nuclear diagnostics and for an understanding of their behavior in the record high 14 MeV neutron yields (up to 4.7 × 1018 n/s) and total number of neutrons (up to 2 × 1019 n) achieved on a tokamak. In this work, we will focus on the 14 MeV high resolution neutron spectrometers based on artificial diamonds which, for the first time, have extensively been used to measure 14 MeV DT neutron spectra with unprecedented energy resolution (Full Width at Half Maximum of ≈1% at 14 MeV). The work will describe their long-term stability and operation over the DTE2 campaign as well as their performance as neutron spectrometers in terms of achieved energy resolution and high rate capability. This important experience will be used to outline the concept of a spectroscopic neutron camera for the SPARC tokamak. The proposed neutron camera will be the first one to feature the dual capability to measure (i) the 2.5 and 14 MeV neutron emissivity profile via the conventional neutron detectors based on liquid or plastics scintillators and (ii) the 14 MeV neutron spectral emission via the use of high-resolution diamond-based spectrometers. The new opportunities opened by the spectroscopic neutron camera to measure plasma parameters will be discussed.

3.
Rev Sci Instrum ; 93(9): 093515, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36182493

RESUMO

The Joint European Torus (JET) is the only tokamak in the world able to operate in Deuterium-Tritium (DT) plasmas. A successful DT experimental campaign, the DTE2, has recently been carried out, providing unique opportunities for studying both physics and technological aspects. In particular, it allowed us to investigate and benchmark the solutions adopted to attenuate the significant 14 MeV neutron flux, needed to enable high-resolution gamma-ray spectroscopy measurements on a tokamak. While in inertial confinement experiments, gamma-rays and neutrons are discriminated through time-of-flight techniques; in magnetic confinement experiments, the neutron attenuators are a key element to allow gamma-ray measurements in order to reestablish the 1 × 105 to 1 background to signal ratio. In this paper, the role of the reference neutron attenuators at JET, based on LiH, has been analyzed and described.

4.
Rev Sci Instrum ; 93(9): 093525, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36182521

RESUMO

The most performant deuterium-tritium (DT) plasma discharges realized by the Joint European Torus (JET) tokamak in the recent DT campaign have produced neutron yields on the order of 1018 n/s. At such high neutron yields, gamma-ray spectroscopy measurements with scintillators are challenging as events from the neutron-induced background often dominate over the signal, leading to a significant fraction of pileup events and instability of the photodetector gain along with the consequent degradation of the reconstructed spectrum. Here, we describe the solutions adopted for the tangential lanthanum bromide spectrometer installed at JET. A data acquisition system with free streaming mode digitization capabilities for the entire duration of the discharge has been used to solve dead-time related issues and a data reconstruction code with pileup recovery and photodetector gain drift restoration has been implemented for off-line analysis of the data. This work focuses on the acquired data storage and parsing, with a detailed explanation of the pileup recovery and gain drift restoration algorithms.

5.
Ann Cardiol Angeiol (Paris) ; 71(1): 6-10, 2022 Feb.
Artigo em Francês | MEDLINE | ID: mdl-34140143

RESUMO

INTRODUCTION: Obesity is a worldwide health problem. Masked hypertension is a relatively recent reported entity with a diagnostic problem. The aim of this study was to determine the clinical and paraclinical characteristics and to identify the predictive factors of masked hypertension in obese patients. METHODS: It is a prospective study including obese patients with normal arterial pressure at office. All of these patients were given ambulatory blood pressure measurement (ABPM) to screen for masked hypertension, laboratory tests and a complete echocardiography study. RESULTS: A total of 50 patients were included. The mean age was 46.52±10.4 years. The mean systolic blood pressure (BP) at office was 120.8±8.8mmHg and the mean diastolic BP was 75±7.3mmHg. The prevalence of masked hypertension in obese adults was 36% with a predominantly non-dipper profile (38%). The study of echocardiographic parameters found dilated left atrium (LA) in 16 patients (32%). The left ventricle (LV) was hypertrophied in 32 patients (64%). The overall LV global longitudinal strain (GLS) was on average -18.85±0.9% and the LA GLS was on average 37.35±4.5%. In our study, metabolic syndrome, low HDL cholesterol, elevated fasting blood glucose, hyperuricemia, LA dilatation, LV hypertrophy, diastolic LV dysfunction and altered myocardial deformities were factors associated with masked hypertension in obese adults. CONCLUSION: It is important to screen for hypertension by ambulatory measurement in at-risk obese patients who present associated cardiovascular risk factors to reduce morbidity and mortality. Echocardiography and speckle tracking analysis could be helpful in detection sub-clinical myocardial deterioration in obese patients with masked hypertension.


Assuntos
Hipertensão , Hipertensão Mascarada , Adulto , Pressão Sanguínea , Monitorização Ambulatorial da Pressão Arterial , Humanos , Hipertensão/complicações , Hipertensão/epidemiologia , Hipertensão Mascarada/complicações , Hipertensão Mascarada/diagnóstico , Hipertensão Mascarada/epidemiologia , Pessoa de Meia-Idade , Obesidade/complicações , Obesidade/epidemiologia , Estudos Prospectivos
6.
Child Neuropsychol ; 26(1): 100-112, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31111792

RESUMO

Previous studies have evidenced cognitive difficulties across various domains in Type 1 Diabetes Mellitus (T1DM) children, but the implicit memory system has not yet been systematically explored.Taking into account that the interplay between memory and perception may be modulated by the semantic category of the stimuli and their salience, we explored explicit and implicit memory using both object and food stimuli to verify whether for T1DM children there is a feebleness in performing the function of memory as a function of the stimuli used.Eighteen T1DM children and 47 healthy children performed an explicit recognition task in which they were requested to judge whether the presented image had already been shown ("old") or not ("new") and an identification priming task in which they were asked to name new and old pictures presented at nine ascending levels of spatial filtering.Results did not reveal any differences between controls and T1DM children in the explicit memory recognition task, whereas some differences between the two groups were found in the identification priming task. In T1DM children, the priming effect was observed only for food images.The dissociation between implicit and explicit memory observed in children with diabetes seems to be modulated by the category of the stimuli, and these results underscore the relevance of taking into account this variable when exploring cognitive functions.


Assuntos
Diabetes Mellitus Tipo 1/complicações , Criança , Feminino , Humanos , Masculino
7.
Rev Sci Instrum ; 89(10): 10I139, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399769

RESUMO

Along the route to the development of a neutral beam injector for ITER, the Padua based Source for Production of Ion of Deuterium Extracted from Rf plasma (SPIDER) and megavolt ITER injector and concept advancement facilities will make use of neutron diagnostics to quantify the homogeneity of the neutral beam profile by measuring the map of the neutron emission from the beam dump with the close-contact neutron emission surface mapping (CNESM) system. Neutrons are here produced from beam-target reactions between the deuterium beam and the deuterons previously adsorbed in the calorimeter. In order to aid the interpretation of the diagnostic data, a dedicated experiment on neutron emission from beam-target reactions with beam parameters approaching those expected at SPIDER has been performed at the Extraction from a Large Ion Source Experiment (ELISE) neutral beam test facility. The time trace of neutron emission has been measured using a calibrated liquid scintillator detector at increasing power densities on the target. Compared to calculations based on the local mixing model, a systematic discrepancy was observed exceeding the statistical accuracy of the measurements and increasing as a linear function of the power density. The data are used to derive an empirical temperature dependent correction for applications to neutron measurements at SPIDER.

8.
Rev Sci Instrum ; 89(10): 10I126, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399810

RESUMO

A set of gamma ray spectrometers has been designed for ITER within the Radial Gamma Ray Spectrometer (RGRS) project. The aim of this project is designing a system, integrated with the ITER radial neutron camera, which is able to measure the gamma-rays emitted from the plasma with a good energy resolution (about 1.5% at 4.44 MeV) and at high counting rates (in excess of 1 MHz). The RGRS will be able to operate both in the D phase and in the full-power DT phase and will measure gamma rays from (i) reactions between fast ions, such as α particles, and light impurities and (ii) bremsstrahlung emission generated by runaway electron interactions with both plasma bulk and tokamak walls. The RGRS detectors are arranged in nine lines of sights (able to cover a radial region with r < a/3), each featuring a large LaBr3 scintillator crystal. Due to the high neutron flux and magnetic field, several solutions have been adopted to guarantee a good signal to background ratio and MHz counting rate capabilities. The RGRS is capable to combine space and energy distribution measurements of α particles and runaway electrons, which will help the study of the fast particle physics in a burning plasma.

9.
Rev Sci Instrum ; 87(11): 11D833, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910565

RESUMO

A prototype Single crystal Diamond Detector (SDD) was installed at the Joint European Torus (JET) in 2013 along an oblique line of sight and demonstrated the possibility to carry out neutron spectroscopy measurements with good energy resolution and detector stability in discharges heated by neutral beam injection and radio-frequency waves. Starting from these positive results, within the Vertical Neutron Spectrometer project of the Joint European Torus, we have developed a pixelated instrument consisting of a matrix of 12 independent SDDs, called the Diamond Vertical Neutron Spectrometer (DVNS), which boosts the detection efficiency of a single SDD by an order of magnitude. In this paper we describe the main features of the DVNS, including the detector design, energy resolution, and data acquisition system for on-line processing. Preliminary spectroscopy measurements of 2.5 MeV neutrons from the present deuterium plasma at JET are finally presented.

10.
Rev Sci Instrum ; 87(11): 11D823, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910604

RESUMO

A Single-crystal Diamond (SD) detector prototype was installed at Joint European Torus (JET) in 2013 and the achieved results have shown its spectroscopic capability of measuring 2.5 MeV neutrons from deuterium plasmas. This paper presents measurements of the SD response function to monoenergetic neutrons, which is a key point for the development of a neutron spectrometer based on SDs and compares them with Monte Carlo simulations. The analysis procedure allows for a good reconstruction of the experimental results. The good pulse height energy resolution (equivalent FWHM of 80 keV at 2.5 MeV), gain stability, insensitivity to magnetic field, and compact size make SDs attractive as compact neutron spectrometers of high flux deuterium plasmas, such as for instance those needed for the ITER neutron camera.

11.
Rev Sci Instrum ; 87(11): 11D822, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910679

RESUMO

This work presents measurements done at the Peking University Van de Graaff neutron source of the response of single crystal synthetic diamond (SD) detectors to quasi-monoenergetic neutrons of 14-20 MeV. The results show an energy resolution of 1% for incoming 20 MeV neutrons, which, together with 1% detection efficiency, opens up to new prospects for fast ion physics studies in high performance nuclear fusion devices such as SD neutron spectrometry of deuterium-tritium plasmas heated by neutral beam injection.

14.
Rev Sci Instrum ; 86(10): 103501, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26520949

RESUMO

Neutron spectroscopy measurements with a single crystal diamond detector have been carried out at JET, for the first time in an experiment aimed at accelerating deuterons to MeV energies with radio frequency heating at the third harmonic. Data are interpreted by means of the expected response function of the detector and are used to extract parameters of the highly non-Maxwellian distribution function generated in this scenario. A comparison with observations using a time of flight and liquid scintillator neutron spectrometers is also presented. The results demonstrate the capability of diamond detectors to contribute to fast ion physics studies at JET and are of more general relevance in view of the application of such detectors for spectroscopy measurements in the neutron camera of next step tokamak devices.

15.
Pathol Biol (Paris) ; 63(4-5): 224-9, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26300241

RESUMO

Triple-negative breast cancers are not a homogeneous subgroup. There is substantial intra-subgroup diversity in tumor biology, prognosis and treatment sensitivity. Then, these triple-negative phenotype (TNP) groups, having specific features, can be again divided into subclasses based on an added immunohistochemical markers. The challenge in treating TNP breast cancers is that they are not responsive to antiestrogens or trastuzumab secondary to negative receptor status, and as a result have a poor prognosis. Therefore, the presence or absence of supplementary markers could help predict which therapies are best suited for patients based on the pattern that their disease markers show. In this review, we will recapitulate the major supplementary biomarkers related to triple-negative breast cancer, which could give new therapeutic options.


Assuntos
Biomarcadores Tumorais/análise , Carcinoma Ductal de Mama/química , Carcinoma Lobular/química , Proteínas de Neoplasias/análise , Neoplasias de Mama Triplo Negativas/química , Antineoplásicos/uso terapêutico , Proteína BRCA1/análise , Carcinoma Ductal de Mama/tratamento farmacológico , Carcinoma Ductal de Mama/etnologia , Carcinoma Lobular/tratamento farmacológico , Carcinoma Lobular/etnologia , Inibidor p16 de Quinase Dependente de Ciclina/análise , Receptores ErbB/análise , Etnicidade/estatística & dados numéricos , Feminino , Genes BRCA1 , Genes erbB-1 , Genes p53 , Humanos , Receptores de Hialuronatos/análise , Terapia de Alvo Molecular , Proteínas Proto-Oncogênicas c-bcl-2/análise , Receptores Androgênicos/análise , Sensibilidade e Especificidade , Neoplasias de Mama Triplo Negativas/classificação , Neoplasias de Mama Triplo Negativas/tratamento farmacológico , Neoplasias de Mama Triplo Negativas/etnologia , Proteína Supressora de Tumor p53/análise
16.
Rev Sci Instrum ; 85(11): 11E101, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430280

RESUMO

Single crystal Diamond Detectors (SDD) are being increasingly exploited for neutron diagnostics in high power fusion devices, given their significant radiation hardness and high energy resolution capabilities. The geometrical efficiency of SDDs is limited by the size of commercially available crystals, which is often smaller than the dimension of neutron beams along collimated lines of sight in tokamak devices. In this work, we present the design and fabrication of a 14 MeV neutron spectrometer consisting of 12 diamond pixels arranged in a matrix, so to achieve an improved geometrical efficiency. Each pixel is equipped with an independent high voltage supply and read-out electronics optimized to combine high energy resolution and fast signals (<30 ns), which are essential to enable high counting rate (>1 MHz) spectroscopy. The response function of a prototype SDD to 14 MeV neutrons has been measured at the Frascati Neutron Generator by observation of the 8.3 MeV peak from the (12)C(n, α)(9)Be reaction occurring between neutrons and (12)C nuclei in the detector. The measured energy resolution (2.5% FWHM) meets the requirements for neutron spectroscopy applications in deuterium-tritium plasmas.

17.
Rev Sci Instrum ; 85(11): 11E108, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430287

RESUMO

A matrix of Silicon Photo Multipliers has been developed for light readout from a large area 1 in. × 1 in. LaBr3 crystal. The system has been characterized in the laboratory and its performance compared to that of a conventional photo multiplier tube. A pulse duration of 100 ns was achieved, which opens up to spectroscopy applications at high counting rates. The energy resolution measured using radioactive sources extrapolates to 3%-4% in the energy range Eγ = 3-5 MeV, enabling gamma-ray spectroscopy measurements at good energy resolution. The results reported here are of relevance in view of the development of compact gamma-ray detectors with spectroscopy capabilities, such as an enhanced gamma-ray camera for high power fusion plasmas, where the use of photomultiplier is impeded by space limitation and sensitivity to magnetic fields.

18.
Rev Sci Instrum ; 85(4): 043506, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24784606

RESUMO

First simultaneous measurements of deuterium-deuterium (DD) and deuterium-tritium neutrons from deuterium plasmas using a Single crystal Diamond Detector are presented in this paper. The measurements were performed at JET with a dedicated electronic chain that combined high count rate capabilities and high energy resolution. The deposited energy spectrum from DD neutrons was successfully reproduced by means of Monte Carlo calculations of the detector response function and simulations of neutron emission from the plasma, including background contributions. The reported results are of relevance for the development of compact neutron detectors with spectroscopy capabilities for installation in camera systems of present and future high power fusion experiments.

19.
Pathol Biol (Paris) ; 62(3): 146-51, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24679587

RESUMO

BACKGROUND: The NSP4 protein of group A rotavirus (RVA) has been recognized as a viral enterotoxin and plays important roles in viral pathogenesis and morphogenesis. Domains involved in structural and functional interactions have been proposed mainly based on the simian SA11 strain. METHODS: NSP4 has been classified into 15 different genotypes (E1-E15), and the aim of this study was to analyze the sequences of 46 RVA strains in order to determine the aminoacid (aa) differences between E1 and E2 genotypes. Another aspect was to characterize the structural and physicochemical properties of these strains. RESULTS: Comparison of deduced aa sequences of the NSP4 protein showed that divergences between NSP4 genotypes E1 and E2 were mostly observed in the VP4-binding, the interspecies variable domain (ISVD) and the double-layered particle (DLP) binding domains. Interestingly, uncommon variations in residues 131 and 138, which are known to be important aa in pathogenesis, were found in one unusual animal derived strain belonging to the E2 genotype. Concerning the structural aspect, no significant differences were noted. CONCLUSION: The presence of punctual aa variations in the NSP4 genotypes may indicate that NSP4 mutates mainly via accumulation of point mutations.


Assuntos
Glicoproteínas/genética , RNA Viral/genética , Rotavirus/genética , Toxinas Biológicas/genética , Proteínas não Estruturais Virais/genética , Sequência de Aminoácidos , Substituição de Aminoácidos , Sequência de Bases , Sequência Conservada , Glicoproteínas/química , Glicosilação , Humanos , Interações Hidrofóbicas e Hidrofílicas , Modelos Moleculares , Dados de Sequência Molecular , Mutação de Sentido Incorreto , Mutação Puntual , Conformação Proteica , Estrutura Terciária de Proteína , Rotavirus/classificação , Rotavirus/isolamento & purificação , Infecções por Rotavirus/microbiologia , Alinhamento de Sequência , Homologia de Sequência , Relação Estrutura-Atividade , Toxinas Biológicas/química , Tunísia , Proteínas não Estruturais Virais/química
20.
Rev Sci Instrum ; 83(2): 02B721, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22380326

RESUMO

A neutron diagnostic for high current deuterium beams is proposed for installation on the spectral shear interferometry for direct electric field reconstruction (SPIDER, Source for Production of Ion of Deuterium Extracted from RF plasma) test beam facility. The proposed detection system is called Close-contact Neutron Emission Surface Mapping (CNESM). The diagnostic aims at providing the map of the neutron emission on the beam dump surface by placing a detector in close contact, right behind the dump. CNESM uses gas electron multiplier detectors equipped with a cathode that also serves as neutron-proton converter foil. The cathode is made of a thin polythene film and an aluminium film; it is designed for detection of neutrons of energy >2.2 MeV with an incidence angle < 45°. CNESM was designed on the basis of simulations of the different steps from the deuteron beam interaction with the beam dump to the neutron detection in the nGEM. Neutron scattering was simulated with the MCNPX code. CNESM on SPIDER is a first step towards the application of this diagnostic technique to the MITICA beam test facility, where it will be used to resolve the horizontal profile of the beam intensity.

SELEÇÃO DE REFERÊNCIAS