Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Orthop Trauma ; 38(9): 491-496, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-39150300

RESUMO

OBJECTIVES: Prophylactic cerclage cables are often placed intraoperatively about a fracture to prevent propagation. However, biomechanical data supporting optimal cable placement location are lacking. The objective of this study was to evaluate the impact of prophylactic cerclage placement location on the propagation of femoral shaft fractures. METHODS: The diaphysis of 14 fresh-frozen cadaveric femora were included. Volumetric bone mineral density in the femoral shaft was obtained from quantitative computed tomography scans. For each specimen, a 5-mm longitudinal fracture was created proximally to simulate a pre-existing fracture. After reaming of the femoral canal, a 3 degrees tapered wedge was advanced with an MTS machine at 0.2 mm/s until failure. The tests were conducted with a CoCr cable placed at varying distances (5 mm, 10 mm, 15 mm, 20 mm, and cableless) from the distal tip of the initial fracture. A compression loadcell was used to measure the cable tension during the tests. The axial force, displacement, and cable tension were monitored for comparison between groups. RESULTS: In the cableless group, the mean force needed to propagate the fracture was 1017.8 ± 450.3 N. With the addition of a cable at 5 mm below the fracture, the failure force nearly doubled to 1970.4 ± 801.1 N (P < 0.001). This also led to significant increases in stiffness (P = 0.006) and total work (P = 0.001) when compared with the control group. By contrast, in the 15 and 20 mm groups, there were no significant changes in the failure force, stiffness, and total work as compared with the control group (P > 0.05). CONCLUSIONS: Propagation of femoral shaft fracture was effectively resisted when a prophylactic cable was placed within 5 mm from the initial fracture, whereas cables placed more than 10 mm below the initial fracture were not effective in preventing fracture propagation.


Assuntos
Cadáver , Fraturas do Fêmur , Humanos , Fraturas do Fêmur/cirurgia , Fraturas do Fêmur/prevenção & controle , Fraturas do Fêmur/fisiopatologia , Feminino , Idoso , Masculino , Fenômenos Biomecânicos , Fios Ortopédicos , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Idoso de 80 Anos ou mais , Pessoa de Meia-Idade
2.
J Arthroplasty ; 38(7S): S292-S297, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36933680

RESUMO

BACKGROUND: Due to increasing volume of total hip arthroplasties, periprosthetic femoral fractures have become a common complication with increased revision burden and perioperative morbidity. The objective of this study was to evaluate the fixation stability of Vancouver B2 fractures treated with 2 techniques. METHODS: A common B2 fracture was created by reviewing 30 type B2 cases. The fracture was then reproduced in 7 pairs of cadaveric femora. The specimens were divided into 2 groups. In Group I ("reduce-first"), the fragments were reduced first, followed by implantation of a tapered fluted stem. In Group II ("ream-first"), the stem was implanted in the distal femur first, followed by fragment reduction and fixation. Each specimen was loaded in a multiaxial testing frame with 70% of peak load during walking. A motion capture system was used to track the motion of the stem and fragments. RESULTS: The average stem diameter in Group II was 16.1 ± 0.4 mm, versus 15.4 ± 0.5 mm in Group I. The fixation stability was not significantly different in the 2 groups. After the testing, the average stem subsidence was 0.36 ± 0.31 mm and 0.19 ± 0.14 mm (P = .17) and the average rotation was 1.67 ± 1.30° and 0.91 ± 1.11° (P = .16) in Groups I and II, respectively. Compared to the stem, there was less motion of the fragments and there was no difference between the 2 groups (P > .05). CONCLUSIONS: When tapered fluted stems were used in combination with cerclage cables for treatment of Vancouver type B2 periprosthetic femoral fractures, both the "reduce-first" and "ream-first" techniques showed adequate stem and fracture stability.


Assuntos
Artroplastia de Quadril , Fraturas do Fêmur , Prótese de Quadril , Fraturas Periprotéticas , Humanos , Prótese de Quadril/efeitos adversos , Reoperação/efeitos adversos , Resultado do Tratamento , Artroplastia de Quadril/efeitos adversos , Fraturas Periprotéticas/cirurgia , Fraturas Periprotéticas/complicações , Fêmur/cirurgia , Fraturas do Fêmur/etiologia , Fraturas do Fêmur/cirurgia , Fixação Interna de Fraturas/efeitos adversos , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA