Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 218
Filtrar
1.
Nat Commun ; 15(1): 5387, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38918361

RESUMO

Creatine chemical exchange saturation transfer (CrCEST) MRI is an emerging high resolution and noninvasive method for measuring muscle specific oxidative phosphorylation (OXPHOS). However, CrCEST measurements are sensitive to changes in muscle pH, which might confound the measurement and interpretation of creatine recovery time (τCr). Even with the same prescribed exercise stimulus, the extent of acidification and hence its impact on τCr is expected to vary between individuals. To address this issue, a method to measure pH pre- and post-exercise and its impact on CrCEST MRI with high temporal resolution is needed. In this work, we integrate carnosine 1H- magnetic resonance spectroscopy (MRS) and 3D CrCEST to establish "mild" and "moderate/intense" exercise stimuli. We then test the dependence of CrCEST recovery time on pH using different exercise stimuli. This comprehensive metabolic imaging protocol will enable personalized, muscle specific OXPHOS measurements in both healthy aging and myriad other disease states impacting muscle mitochondria.


Assuntos
Imageamento por Ressonância Magnética , Músculo Esquelético , Fosforilação Oxidativa , Espectroscopia de Prótons por Ressonância Magnética , Imageamento por Ressonância Magnética/métodos , Humanos , Músculo Esquelético/metabolismo , Músculo Esquelético/diagnóstico por imagem , Masculino , Concentração de Íons de Hidrogênio , Espectroscopia de Prótons por Ressonância Magnética/métodos , Creatina/metabolismo , Exercício Físico/fisiologia , Feminino , Adulto
2.
medRxiv ; 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38645233

RESUMO

Purpose: This goal of this study was to optimize spectrally selective 1H MRS methods for large volume acquisition of low concentration metabolites with downfield resonances at 7T and 3T, with particular attention paid to detection of nicotinamide adenine dinucleotide (NAD+) and tryptophan. Methods: Spectrally selective excitation was used to avoid magnetization transfer effects with water, and various sinc pulses were compared to a pure-phase E-BURP pulse. Localization using a single slice selective pulse was compared to voxel-based localization that used three orthogonal refocusing pulses, and low bandwidth refocusing pulses were used to take advantage of the chemical shift displacement of water. A technique for water sideband removal was added, and a method of coil channel combination for large volumes was introduced. Results: Proposed methods were compared qualitatively to previously-reported techniques at 7T. Sinc pulses resulted in reduced water signal excitation and improved spectral quality, with a symmetric, low bandwidth-time product pulse performing best. Single slice localization allowed shorter TEs with large volumes, enhancing signal, while low bandwidth slice selective localization greatly reduced the observed water signal. Gradient cycling helped remove water sidebands, and frequency aligning and pruning individual channels narrowed spectral linewidths. High quality brain spectra of NAD+ and tryptophan are shown in four subjects at 3T. Conclusion: Improved spectral quality with higher downfield signal, shorter TE, lower nuisance signal, reduced artifacts, and narrower peaks was realized at 7T. These methodological improvements allowed for previously unachievable detection of NAD+ and tryptophan in human brain at 3T in under five minutes.

3.
NMR Biomed ; : e5158, 2024 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-38584133

RESUMO

PURPOSE: In vivo quantification of lactate has numerous applications in studying the pathology of both cerebral and musculoskeletal systems. Due to its low concentration (~0.5-1 mM), and overlap with lipid signals, traditional 1H MR spectra acquired in vivo using a small voxel and short echo time often result in an inadequate signal to detect and resolve the lactate peak, especially in healthy human volunteers. METHODS: In this study, using a semi-LASER acquisition with long echo time (TE = 288 ms) and large voxel size (80 × 70 × 20 mm3), we clearly visualize the combined signal of lactate and threonine. Therefore, we call the signal at 1.33 ppm Lac+ and quantify Lac+ concentration from water suppressed spectra in healthy human brains in vivo. Four participants (22-37 years old; mean age = 28 ± 5.4; three male, one female) were scanned on four separate days, and on each day four measurements were taken. Intra-day values are calculated for each participant by comparing the four measurements on a single day. Inter-day values were calculated using the mean intra-day measurements. RESULTS: The mean intra-participant Lac+ concentration, standard deviation (SD), and coefficient of variation (CV) ranged from 0.49 to 0.61 mM, 0.02 to 0.07 mM, and 4% to 13%, respectively, across four volunteers. The inter-participant Lac+ concentration, SD, and CV was 0.53 mM, ±0.06 mM, and 11%. CONCLUSION: Repeatability is shown in Lac+ measurement in healthy human brain using a long echo time semi-LASER sequence with a large voxel in about 3.5 min at 3 T.

4.
Magn Reson Med ; 92(3): 1277-1289, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38469893

RESUMO

PURPOSE: Ultrahigh field (≥7 T) MRI is at the cutting edge of medical imaging, enabling enhanced spatial and spectral resolution as well as enhanced susceptibility contrast. However, transmit ( B 1 + $$ {\mathrm{B}}_1^{+} $$ ) field inhomogeneity due to standing wave effects caused by the shortened RF wavelengths at 7 T is still a challenge to overcome. Novel hardware methods such as dielectric pads have been shown to improve the B 1 + $$ {\mathrm{B}}_1^{+} $$ field inhomogeneity but are currently limited in their corrective effect by the range of high-permittivity materials available and have a fixed shelf life. In this work, an optimized metasurface design is presented that demonstrates in vivo enhancement of the B 1 + $$ {\mathrm{B}}_1^{+} $$ field. METHODS: A prototype metasurface was optimized by an empirical capacitor sweep and by varying the period size. Phantom temperature experiments were performed to evaluate potential metasurface heating effects during scanning. Lastly, in vivo gradient echo images and B 1 + $$ {\mathrm{B}}_1^{+} $$ maps were acquired on five healthy subjects on a 7 T system. Dielectric pads were also used as a comparison throughout the work as a standard comparison. RESULTS: The metasurfaces presented here enhanced the average relative SNR of the gradient echo images by a factor of 2.26 compared to the dielectric pads factor of 1.61. Average B 1 + $$ {\mathrm{B}}_1^{+} $$ values reflected a similar enhancement of 27.6% with the metasurfaces present versus 8.9% with the dielectric pads. CONCLUSION: The results demonstrate that metasurfaces provide superior performance to dielectric padding as shown by B 1 + $$ {\mathrm{B}}_1^{+} $$ maps reflecting their direct effects and resulting enhancements in image SNR at 7 T.


Assuntos
Desenho de Equipamento , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Imageamento por Ressonância Magnética/instrumentação , Humanos , Perna (Membro)/diagnóstico por imagem , Adulto , Aumento da Imagem/métodos , Feminino , Masculino , Processamento de Imagem Assistida por Computador/métodos , Algoritmos , Razão Sinal-Ruído
5.
bioRxiv ; 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38464048

RESUMO

Introduction: The purpose of this study was to use a single-slice spectrally-selective sequence to measure T 1 and T 2 relaxation times of NAD + proton resonances in the downfield 1 H MRS spectrum in human brain at 7 T in vivo and assess the propagation of relaxation time uncertainty in NAD + quantification. Methods: Downfield spectra from 7 healthy volunteers were acquired at multiple echo times in all subjects to measure T 2 relaxation, and saturation recovery data were to measure T 1 relaxation. The downfield acquisition used a spectrally-selective 90° sinc pulse for excitation centered at 9.1 ppm with a bandwidth of 2 ppm, followed by a 180° spatially-selective Shinnar-Le Roux refocusing pulse for localization. For the multiple echo experiment, spectra were collected with echo times ranging from 13 to 33 ms. For the saturation recovery experiment, saturation was performed prior to excitation using the same spectrally-selective sinc pulse as was used for excitation. Saturation delay times (TS) ranged from 100 to 600 ms. Uncertainty propagation analysis was performed analytically and with Monte Carlo simulation. Results: The mean ± standard deviation of T 1 relaxation times of the H2, H6, and H4 protons were 152.7 ± 16.6, 163.6 ± 22.3, and 169.9 ± 11.2 ms, respectively. The mean ± standard deviation of T 2 relaxation times of the H2, H6, and H4 protons were 32.5 ± 7.0, 27.4 ± 5.2, and 38.1 ± 11.7 ms, respectively. The mean R 2 of the H2 and H6 T 1 fits were 0.98. The mean R 2 of the H4 proton T 1 fit was 0.96. The mean R 2 of the T 2 fits of the H2 and H4 proton resonances were 0.98, while the mean R 2 of the T 2 fits of the H4 proton was 0.93. The relative uncertainty in NAD + concentration due to relaxation time uncertainty was 8.5%-11%. Conclusion: Using downfield spectrally-selective spectroscopy with single-slice localization, we found NAD + T 1 and T 2 relaxation times to be approximately 162 ms and 32 ms respectively in the human brain in vivo at 7 T.

6.
PLoS One ; 19(2): e0297310, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38363747

RESUMO

INTRODUCTION: With nicotine dependence being a significant healthcare issue worldwide there is a growing interest in developing novel therapies and diagnostic aids to assist in treating nicotine addiction. Glutamate (Glu) plays an important role in cognitive function regulation in a wide range of conditions including traumatic brain injury, aging, and addiction. Chemical exchange saturation transfer (CEST) imaging via ultra-high field MRI can image the exchange of certain saturated labile protons with the surrounding bulk water pool, making the technique a novel tool to investigate glutamate in the context of addiction. The aim of this work was to apply glutamate weighted CEST (GluCEST) imaging to study the dorsal anterior cingulate cortex (dACC) in a small population of smokers and non-smokers to determine its effectiveness as a biomarker of nicotine use. METHODS: 2D GluCEST images were acquired on 20 healthy participants: 10 smokers (ages 29-50) and 10 non-smokers (ages 25-69), using a 7T MRI system. T1-weighted images were used to segment the GluCEST images into white and gray matter tissue and further into seven gray matter regions. Wilcoxon rank-sum tests were performed, comparing mean GluCEST contrast between smokers and non-smokers across brain regions. RESULTS: GluCEST levels were similar between smokers and non-smokers; however, there was a moderate negative age dependence (R2 = 0.531) in smokers within the cingulate gyrus. CONCLUSION: Feasibility of GluCEST imaging was demonstrated for in vivo investigation of smokers and non-smokers to assess glutamate contrast differences as a potential biomarker with a moderate negative age correlation in the cingulate gyrus suggesting reward network involvement.


Assuntos
Ácido Glutâmico , Nicotina , Humanos , Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Neuroimagem , Biomarcadores
7.
NMR Biomed ; 37(4): e5094, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38214202

RESUMO

We present a review outlining the basic mechanism, background, recent technical developments, and clinical applications of aqueous dielectric padding in the field of MRI. Originally meant to be a temporary solution, it has gained traction as an effective method for correcting B1 + inhomogeneities due to the unique properties of the calcium titanate and barium titanate perovskites used. Aqueous dielectric pads have used a variety of high-permittivity materials over the years to improve the quality of MRI acquisitions at 1.5 and 3 T and more recently for 7 T neuroimaging applications. The technical development and assessment of these pads have been advanced by an increased use of mathematical modeling and electromagnetic simulations. These tools have allowed for a more complete understanding of the physical interactions between dielectric pads and the RF coil, making testing and safety assessments more accurate. The ease of use and effectiveness that dielectric pads offer have allowed them to become more commonplace in tackling imaging challenges in more clinically focused environments. More recently, they have seen usage not only in anatomical imaging methods but also in specialized metabolic imaging sequences such as GluCEST and NOEMTR . New colossally high-permittivity materials have been proposed; however, practical utilization has been a continued challenge due to unfavorable frequency dependences as well as safety limitations. A new class of metasurfaces has been under development to address the shortcomings of conventional dielectric padding while also providing increased performance in enhancing MRI images.


Assuntos
Imageamento por Ressonância Magnética , Neuroimagem , Imageamento por Ressonância Magnética/métodos , Neuroimagem/métodos , Água , Ondas de Rádio , Espectroscopia de Ressonância Magnética , Imagens de Fantasmas
8.
Front Aging Neurosci ; 15: 1266859, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37876875

RESUMO

Non-invasive methods of detecting early-stage Alzheimer's disease (AD) can provide valuable insight into disease pathology, improving the diagnosis and treatment of AD. Nuclear Overhauser enhancement (NOE) MRI is a technique that provides image contrast sensitive to lipid and protein content in the brain. These macromolecules have been shown to be altered in Alzheimer's pathology, with early disruptions in cell membrane integrity and signaling pathways leading to the buildup of amyloid-beta plaques and neurofibrillary tangles. We used template-based analyzes of NOE MRI data and the characteristic Z-spectrum, with parameters optimized for increase specificity to NOE, to detect changes in lipids and proteins in an AD mouse model that recapitulates features of human AD. We find changes in NOE contrast in the hippocampus, hypothalamus, entorhinal cortex, and fimbria, with these changes likely attributed to disruptions in the phospholipid bilayer of cell membranes in both gray and white matter regions. This study suggests that NOE MRI may be a useful tool for monitoring early-stage changes in lipid-mediated metabolism in AD and other disorders with high spatial resolution.

9.
medRxiv ; 2023 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-37808798

RESUMO

Introduction: Acute alcohol intake decreases brain glucose metabolism and increases brain uptake of acetate, a metabolite of alcohol. Individuals with alcohol use disorder (AUD) show elevated brain acetate metabolism at the expense of glucose, a shift in energy utilization that persists beyond acute intoxication. We recently reported that nutritional ketosis and administration of ketone bodies as an alternative energy source to glucose reduce alcohol withdrawal severity and alcohol craving in AUD. However, the regional effects of nutritional ketosis on brain ketone (beta-hydroxybutyrate [BHB]) and glucose metabolism have not been studied in AUD. Methods: Five participants with AUD underwent two magnetic resonance imaging (MRI) sessions and 4 participants with AUD underwent two positron emission tomography (PET) sessions with 18 F-fluorodeoxyglucose. All participants completed one session without KE intervention and one session during which they consumed 395 mg/kg (R) -3-hydroxybutyl (R) -3-hydroxybutyrate Ketone Ester (KE) intervention (TdeltaS Global Inc.) before the scan. The order of the sessions was randomized. For the PET cohort, blood glucose and ketone levels were assessed and voxel-wise maps of the cerebral metabolic rate of glucose (CMRglc) were computed at each session. For the MRI cohort, brain anterior cingulate BHB levels were assessed using magnetic resonance spectroscopy. Results: A single dose of KE elevated blood BHB and anterior cingulate BHB levels compared to baseline. Moreover, blood glucose levels were lower with KE than baseline, and whole-brain CMRglc decreased by 17%. The largest KE-induced CMRglc reductions were in the frontal, occipital, cortex, and anterior cingulate cortices. Conclusion: These findings provide preliminary evidence that KE administration elevates ketone and reduces brain glucose metabolism in humans, consistent with a shift from glucose to ketones as a brain energy source. Average reductions in CMRglc of 17% are similar to global average reductions documented with administration of 0.25-0.5 g/kg of alcohol. Documenting the clinical and neurometabolic effects of nutritional ketosis will yield fundamental knowledge as to its potential beneficial effects as a treatment for AUD and its underlying neural mechanisms.

10.
Magn Reson Med ; 90(4): 1537-1546, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37279010

RESUMO

PURPOSE: Nuclear Overhauser effect magnetization transfer ratio (NOEMTR ) is a technique used to investigate brain lipids and macromolecules in greater detail than other techniques and benefits from increased contrast at 7 T. However, this contrast can become degraded because of B 1 + $$ {\mathrm{B}}_1^{+} $$ inhomogeneities present at ultra-high field strengths. High-permittivity dielectric pads (DP) have been used to correct for these inhomogeneities via displacement currents generating secondary magnetic fields. The purpose of this work is to demonstrate that dielectric pads can be used to mitigate B 1 + $$ {\mathrm{B}}_1^{+} $$ inhomogeneities and improve NOEMTR contrast in the temporal lobes at 7 T. METHODS: Partial 3D NOEMTR contrast images and whole brain B 1 + $$ {\mathrm{B}}_1^{+} $$ field maps were acquired on a 7 T MRI across six healthy subjects. Calcium titanate DP, having a relative permittivity of 110, was placed next to the subject's head near the temporal lobes. Pad corrected NOEMTR images had a separate postprocessing linear correction applied. RESULTS: DP provided supplemental B 1 + $$ {\mathrm{B}}_1^{+} $$ to the temporal lobes while also reducing the B 1 + $$ {\mathrm{B}}_1^{+} $$ magnitude across the posterior and superior regions of the brain. This resulted in a statistically significant increase in NOEMTR contrast in substructures of the temporal lobes both with and without linear correction. The padding also produced a convergence in NOEMTR contrast toward approximately equal mean values. CONCLUSION: NOEMTR images showed significant improvement in temporal lobe contrast when DP were used, which resulted from an increase in B 1 + $$ {\mathrm{B}}_1^{+} $$ homogeneity across the entire brain slab. DP-derived improvements in NOEMTR are expected to increase the robustness of the brain substructural measures both in healthy and pathological conditions.


Assuntos
Encéfalo , Cabeça , Humanos , Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Mapeamento Encefálico , Campos Magnéticos , 5-Metiltetra-Hidrofolato-Homocisteína S-Metiltransferase
11.
Food Microbiol ; 114: 104299, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37290875

RESUMO

The FDA Bacteriological Analytical Manual (BAM) Salmonella culture method takes at least 3 days for a presumptive positive result. The FDA developed a quantitative PCR (qPCR) method to detect Salmonella from 24-h preenriched cultures, using ABI 7500 PCR system. The qPCR method has been evaluated as a rapid screening method for a broad range of foods by single laboratory validation (SLV) studies. The present multi-laboratory validation (MLV) study was aimed to measure the reproducibility of this qPCR method and compare its performance with the culture method. Sixteen laboratories participated in two rounds of MLV study to analyze twenty-four blind-coded baby spinach test portions each. The first round yielded ∼84% and ∼82% positive rates across laboratories for the qPCR and culture methods, respectively, which were both outside the fractional range (25%-75%) required for fractionally inoculated test portions by the FDA's Microbiological Method Validation Guidelines. The second round yielded ∼68% and ∼67% positive rates. The relative level of detection (RLOD) for the second-round study was 0.969, suggesting that qPCR and culture methods had similar sensitivity (p > 0.05). The study demonstrated that the qPCR yields reproducible results and is sufficiently sensitive and specific for the detection of Salmonella in food.


Assuntos
Microbiologia de Alimentos , Spinacia oleracea , Reação em Cadeia da Polimerase em Tempo Real/métodos , Laboratórios , Reprodutibilidade dos Testes , Salmonella/genética
12.
J Vet Diagn Invest ; 35(5): 470-483, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37313802

RESUMO

Anticoagulant rodenticides (ARs) are used to control rodent populations. Poisoning of non-target species can occur by accidental consumption of commercial formulations used for rodent control. A robust method for determining ARs in animal tissues is important for animal postmortem diagnostic and forensic purposes. We evaluated an ultra-performance liquid chromatography coupled with mass spectrometry (UPLC-MS) method to quantify 8 ARs (brodifacoum, bromadiolone, chlorophacinone, coumachlor, dicoumarol, difethialone, diphacinone, warfarin) in a wide range of animal (bovine, canine, chicken, equine, porcine) liver samples, including incurred samples. We further evaluated UPLC-MS in 2 interlaboratory comparison (ILC) studies; one an ILC exercise (ICE), the other a proficiency test (PT). The limits of detection of UPLC-MS were 0.3-3.1 ng/g, and the limits of quantification were 0.8-9.4 ng/g. The recoveries obtained using UPLC-MS were 90-115%, and relative SDs were 1.2-13% for each of the 8 ARs for the 50, 500, and 2,000 ng/g spiked liver samples. The overall accuracy from the laboratories participating in the 2 ILC studies (4 and 11 laboratories for ICE and PT studies, respectively) were 86-118%, with relative repeatability SDs of 3.7-11%, relative reproducibility SDs of 7.8-31.2%, and Horwitz ratio values of 0.5-1.5. Via the ILC studies, we verified the accuracy of UPLC-MS for AR analysis in liver matrices and demonstrated that ILC can be utilized to evaluate performance characteristics of analytical methods.


Assuntos
Anticoagulantes , Técnicas de Química Analítica , Cumarínicos , Indanos , Rodenticidas , Animais , Técnicas de Química Analítica/métodos , Técnicas de Química Analítica/normas , Técnicas de Química Analítica/veterinária , Rodenticidas/análise , Anticoagulantes/análise , Fígado/química , Espectrometria de Massa com Cromatografia Líquida , Indanos/análise , Cumarínicos/análise , Limite de Detecção , Reprodutibilidade dos Testes
13.
Magn Reson Med ; 90(3): 1166-1171, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37125620

RESUMO

PURPOSE: The purpose of this study was to identify and characterize newly discovered resonances appearing in the downfield proton MR spectrum (DF 1 H MRS) of the human calf muscle in vivo at 7T. METHODS: Downfield 1 H MRS was performed on the calf muscle of five healthy volunteers at 7T. A spectrally selective 90° E-BURP RF pulse with an excitation center frequency at 10.3 ppm and an excitation bandwidth of 2 ppm was used for DF 1 H MRS acquisition. RESULTS: In all participants, we observed new resonances at 9.7, 10.1, 10.3, and 10.9 ppm in the DF 1 H MRS. Phantom experiments at 37°C strongly suggest the new resonance at 9.7 ppm could be from H2-proton of the nicotinamide rings in nicotinamide riboside (NR) and nicotinamide mononucleotide (NMN) while the resonance at 10.1 ppm could be attributed to the indole -NH proton of L-tryptophan. We observed that the resonances at 10.1 and 10.9 ppm are significantly suppressed when the water resonance is saturated, indicating that these peaks have either 1 H chemical exchange or cross-relaxation with water. Conversely, the resonances at 9.7 and 10.3 ppm exhibit moderate signal reduction in the presence of water saturation. CONCLUSION: We have identified new proton resonances in vivo in human calf muscle occurring at chemical shifts of 9.7, 10.1, 10.3, and 10.9 ppm. These preliminary results are promising for investigating the role of NR/NMN and L-tryptophan metabolism in understanding the de novo and salvage pathways of NAD+ synthesis in skeletal muscle.


Assuntos
NAD , Prótons , Humanos , Triptofano , Músculo Esquelético/diagnóstico por imagem , Água
14.
J Appl Lab Med ; 8(4): 726-741, 2023 07 05.
Artigo em Inglês | MEDLINE | ID: mdl-37222567

RESUMO

BACKGROUND: Throughout the COVID-19 pandemic, veterinary diagnostic laboratories have tested diagnostic samples for SARS-CoV-2 both in animals and over 6 million human samples. An evaluation of the performance of those laboratories is needed using blinded test samples to ensure that laboratories report reliable data to the public. This interlaboratory comparison exercise (ILC3) builds on 2 prior exercises to assess whether veterinary diagnostic laboratories can detect Delta and Omicron variants spiked in canine nasal matrix or viral transport medium. METHODS: The ILC organizer was an independent laboratory that prepared inactivated Delta variant at levels of 25 to 1000 copies per 50 µL of nasal matrix for blinded analysis. Omicron variant at 1000 copies per 50 µL of transport medium was also included. Feline infectious peritonitis virus (FIPV) RNA was used as a confounder for specificity assessment. Fourteen test samples were prepared for each participant. Participants used their routine diagnostic procedures for RNA extraction and real-time reverse transcriptase-PCR. Results were analyzed according to International Organization for Standardization (ISO) 16140-2:2016. RESULTS: Overall, laboratories demonstrated 93% detection for Delta and 97% for Omicron at 1000 copies per 50 µL. Specificity was 97% for blank samples and 100% for blank samples with FIPV. No differences in Cycle Threshold (Ct) values were significant for samples with the same virus levels between N1 and N2 markers, nor between the 2 variants. CONCLUSIONS: The results indicated that all ILC3 participants were able to detect both Delta and Omicron variants. The canine nasal matrix did not significantly affect SARS-CoV-2 detection.


Assuntos
COVID-19 , SARS-CoV-2 , Gatos , Humanos , Animais , Cães , SARS-CoV-2/genética , COVID-19/diagnóstico , COVID-19/veterinária , Laboratórios , Pandemias , RNA , Teste para COVID-19
15.
Magn Reson Med ; 90(1): 259-269, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36971349

RESUMO

PURPOSE: To monitor the metabolic turnover of ß-hydroxybutyrate (BHB) oxidation using 2 H-MRS in conjunction with intravenous administration of 2 H labeled BHB. METHODS: Nine-month-old mice were infused with [3,4,4,4]-2 H4 -BHB (d4 -BHB; 3.11 g/kg) through the tail vein using a bolus variable infusion rate for a period of 90 min. The labeling of downstream cerebral metabolites from the oxidative metabolism of d4 -BHB was monitored using 2 H-MRS spectra acquired with a home-built 2 H surface coil on a 9.4T preclinical MR scanner with a temporal resolution of 6.25 min. An exponential model was fit to the BHB and glutamate/glutamine (Glx) turnover curves to determine rate constants of metabolite turnover and to aid in the visualization of metabolite time courses. RESULTS: Deuterium label was incorporated into Glx from BHB metabolism through the tricarboxylic acid (TCA) cycle, with an increase in the level of [4,4]-2 H2 -Glx (d2 -Glx) over time and reaching a quasi-steady state concentration of ∼0.6 ± 0.1 mM following 30 min of infusion. Complete oxidative metabolic breakdown of d4 -BHB also resulted in the formation of semi-heavy water (HDO), with a four-fold (10.1 to ∼42.1 ± 7.3 mM) linear (R2  = 0.998) increase in its concentration by the end of infusion. The rate constant of Glx turnover from d4 -BHB metabolism was determined to be 0.034 ± 0.004 min-1 . CONCLUSION: 2 H-MRS can be used to monitor the cerebral metabolism of BHB with its deuterated form by measuring the downstream labeling of Glx. The integration of 2 H-MRS with deuterated BHB substrate provides an alternative and clinically promising MRS tool to detect neurometabolic fluxes in healthy and disease conditions.


Assuntos
Encéfalo , Camundongos , Animais , Ácido 3-Hidroxibutírico , Deutério , Oxirredução , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo
16.
Magn Reson Med ; 89(6): 2295-2304, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36744726

RESUMO

PURPOSE: Nuclear Overhauser effect (NOE) is based on dipolar cross-relaxation mechanism that enables the indirect detection of aliphatic protons via the water proton signal. This work focuses on determining the reproducibility of NOE magnetization transfer ratio (NOEMTR ) and isolated or relayed NOE (rNOE) contributions to the NOE MRI of the healthy human brain at 7 Tesla (T). METHODS: We optimized the B 1 + $$ {\mathrm{B}}_1^{+} $$ amplitude and length of the saturation pulse by acquiring NOE images with different B 1 + $$ {\mathrm{B}}_1^{+} $$ values with multiple saturation lengths. Repeated NOE MRI measurements were made on five healthy volunteers by using optimized saturation pulse parameters including correction of B0 and B 1 + $$ {\mathrm{B}}_1^{+} $$ inhomogeneities. To isolate the individual contributions from z-spectra, we have fit the NOE z-spectra using multiple Lorentzians and calculated the total contribution from each pool contributing to the overall NOEMTR contrast. RESULTS: We found that a saturation amplitude of 0.72 µT and a length of 3 s provided the highest contrast. We found that the mean NOEMTR value in gray matter (GM) was 26%, and in white matter (WM) was 33.3% across the 3D slab of the brain. The mean rNOE contributions from GM and WM values were 8.9% and 9.6%, which were ∼10% of the corresponding total NOEMTR signal. The intersubject coefficient of variations (CoVs) of NOEMTR from GM and WM were 4.5% and 6.5%, respectively, whereas the CoVs of rNOE were 4.8% and 5.6%, respectively. The intrasubject CoVs of the NOEMTR range was 2.1%-4.2%, and rNOE range was 2.9%-10.5%. CONCLUSION: This work has demonstrated an excellent reproducibility of both inter- and intrasubject NOEMTR and rNOE metrics in healthy human brains at 7 T.


Assuntos
Algoritmos , Neoplasias Encefálicas , Humanos , Reprodutibilidade dos Testes , Interpretação de Imagem Assistida por Computador/métodos , Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Prótons
17.
Magn Reson Med ; 90(1): 11-20, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36807934

RESUMO

PURPOSE: The purpose of this study was to characterize the 1 H downfield MR spectrum from 8.0 to 10.0 ppm of human skeletal muscle at 7 T and determine the T1 and cross-relaxation rates of observed resonances. METHODS: We performed downfield MRS in the calf muscle of 7 healthy volunteers. Single-voxel downfield MRS was collected using alternately selective or broadband inversion-recovery sequences and spectrally selective 90° E-BURP RF pulse excitation centered at 9.0 ppm with bandwidth = 600 Hz (2.0 ppm). MRS was collected using TIs of 50-2500 ms. We modeled recovery of the longitudinal magnetization of three observable resonances using two models: (1) a three-parameter model accounting for the apparent T1 recovery and (2) a Solomon model explicitly including cross-relaxation effects. RESULTS: Three resonances were observed in human calf muscle at 7 T at 8.0, 8.2, and 8.5 ppm. We found broadband (broad) and selective (sel) inversion recovery T1 = mean ± SD (ms): T1-broad,8.0ppm = 2108.2 ± 664.5, T1-sel,8.0ppm = 753.6 ± 141.0 (p = 0.003); T1-broad,8.2ppm = 2033.5 ± 338.4, T1-sel,8.2ppm = 135.3 ± 35.3 (p < 0.0001); and T1-broad,8.5ppm = 1395.4 ± 75.4, T1-sel,8.5ppm = 107.1 ± 40.0 (p < 0.0001). Using the Solomon model, we found T1 = mean ± SD (ms): T1-8.0ppm = 1595.6 ± 491.1, T1-8.2ppm = 1737.2 ± 963.7, and T1-8.5ppm = 849.8 ± 282.0 (p = 0.04). Post hoc tests corrected for multiple comparisons showed no significant difference in T1 between peaks. The cross-relaxation rate σAB = mean ± SD (Hz) of each peak was σAB,8.0ppm = 0.76 ± 0.20, σAB,8.2ppm = 5.31 ± 2.27, and σAB,8.5ppm = 7.90 ± 2.74 (p < 0.0001); post hoc t-tests revealed the cross-relaxation rate of the 8.0 ppm peak was significantly slower than the peaks at 8.2 ppm (p = 0.0018) and 8.5 ppm (p = 0.0005). CONCLUSION: We found significant differences in effective T1 and cross-relaxation rates of 1 H resonances between 8.0 and 8.5 ppm in the healthy human calf muscle at 7 T.


Assuntos
Músculo Esquelético , Humanos , Espectroscopia de Ressonância Magnética , Músculo Esquelético/diagnóstico por imagem
18.
NMR Biomed ; 36(6): e4780, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-35642353

RESUMO

Glutamate is the primary excitatory neurotransmitter in the mammalian central nervous system. As such, its proper regulation is essential to the healthy function of the human brain, and dysregulation of glutamate metabolism and compartmentalization underlies numerous neurological and neuropsychiatric pathologies. Glutamate-weighted chemical exchange saturation transfer (gluCEST) MRI is one of the only ways to non-invasively observe the relative concentration and spatial distribution of glutamate in the human brain. In the past 10 years, gluCEST has developed from a proof-of-concept experiment carried out in imaging phantoms and model systems to an increasingly sophisticated technique applied to reveal deviations from baseline neural metabolism in human beings, most notably in patients experiencing seizures of various origins or those on the psychosis spectrum. This article traces that progress, including in-depth discussion of the technical specifics of gluCEST and potential challenges to performing these experiments rigorously. We discuss the neurobiological context of glutamate, including the widely accepted hypotheses and models in the literature regarding its involvement in neurodegenerative diseases and other pathology. We then review the state of the art of in vivo glutamate detection by magnetic resonance imaging and the limitations on this front of in vivo MR spectroscopy. The gluCEST experiment is introduced and its advantages, challenges and limitations are thoroughly explored, beginning with the phantom experiment results demonstrated in the initial publication, through the latest approaches to correcting human brain images for B1 inhomogeneity. We then give a comprehensive overview of preclinical applications demonstrated to date, including Alzheimer's disease, Parkinson's disease, Huntington's disease, Traumatic brain injury and cancer, followed by a similar discussion of human studies. Finally, we highlight emerging applications, and discuss technical improvements on the horizon that hold promise for improving the robustness and versatility of gluCEST and its increasing presence in the arena of translational and precision medicine.


Assuntos
Lesões Encefálicas Traumáticas , Ácido Glutâmico , Animais , Humanos , Ácido Glutâmico/metabolismo , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Lesões Encefálicas Traumáticas/metabolismo , Mamíferos/metabolismo
19.
Magn Reson Med ; 89(4): 1357-1367, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36372994

RESUMO

PURPOSE: The nuclear Overhauser effect (NOE) quantification from the steady-state NOE imaging suffers from multiple confounding non-NOE-specific sources, including direct saturation, magnetization transfer, and relevant chemical exchange species, and is affected by B0 and B1 + inhomogeneities. The B0 -dependent and B1 + -dependent data needed for deconvolving these confounding effects would increase the scan time substantially, leading to other issues such as patient tolerability. Here, we demonstrate the feasibility of brain lipid mapping using an easily implementable transient NOE (tNOE) approach. METHODS: This 7T study used a frequency-selective inversion pulse at a range of frequency offsets between 1.0 and 5.0 parts per million (ppm) and -5.0 and -1.0 ppm relative to bulk water peak. This was followed by a fixed/variable mixing time and then a single-shot 2D turbo FLASH readout. The feasibility of tNOE measurements is demonstrated on bovine serum albumin phantoms and healthy human brains. RESULTS: The tNOE measurements from bovine serum albumin phantoms were found to be independent of physiological pH variations. Both bovine serum albumin phantoms and human brains showed broad tNOE contributions centered at approximately -3.5 ppm relative to water peak, with presumably aliphatic moieties in lipids and proteins being the dominant contributors. Less prominent tNOE contributions of approximately +2.5 ppm relative to water, presumably from aromatic moieties, were also detected. These aromatic signals were free from any CEST signals. CONCLUSION: In this study, we have demonstrated the feasibility of tNOE in human brain at 7 T. This method is more scan-time efficient than steady-state NOE and provides NOE measurement with minimal confounders.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Humanos , Algoritmos , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Estudos de Viabilidade , Imageamento por Ressonância Magnética/métodos , Sensibilidade e Especificidade , Soroalbumina Bovina , Água/metabolismo , Imagens de Fantasmas
20.
Hum Brain Mapp ; 44(2): 549-558, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-36173151

RESUMO

Temporal lobe epilepsy (TLE) is one of the most common subtypes of focal epilepsy, with mesial temporal sclerosis (MTS) being a common radiological and histopathological finding. Accurate identification of MTS during presurgical evaluation confers an increased chance of good surgical outcome. Here we propose the use of glutamate-weighted chemical exchange saturation transfer (GluCEST) magnetic resonance imaging (MRI) at 7 Tesla for mapping hippocampal glutamate distribution in epilepsy, allowing to differentiate lesional from non-lesional mesial TLE. We demonstrate that a directional asymmetry index, which quantifies the relative difference between GluCEST contrast in hippocampi ipsilateral and contralateral to the seizure onset zone, can differentiate between sclerotic and non-sclerotic hippocampi, even in instances where traditional presurgical MRI assessments did not provide evidence of sclerosis. Overall, our results suggest that hippocampal glutamate mapping through GluCEST imaging is a valuable addition to the presurgical epilepsy evaluation toolbox.


Assuntos
Epilepsia do Lobo Temporal , Epilepsia , Humanos , Epilepsia do Lobo Temporal/diagnóstico por imagem , Epilepsia do Lobo Temporal/cirurgia , Epilepsia do Lobo Temporal/patologia , Ácido Glutâmico , Hipocampo/diagnóstico por imagem , Hipocampo/patologia , Imageamento por Ressonância Magnética/métodos , Epilepsia/patologia , Esclerose/diagnóstico por imagem , Esclerose/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...