Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Tipo de estudo
Intervalo de ano de publicação
1.
BMJ Case Rep ; 16(2)2023 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-36731946

RESUMO

Flecainide is a class 1C antiarrhythmic and is highly effective for treating a wide range of arrhythmias. It is not licensed for children under the age of 12 years, but has been used safely for years in young children, particularly when first-line agents are not effective. Although toxicity does occur in both adult and paediatric populations, there have been very few reported instances of flecainide toxicity in neonates and children. Supratherapeutic levels of flecainide manifests on ECG with prolongation of the PR interval, QRS duration and QT, and can lead to life-threatening arrhythmias. In milk-fed infants receiving flecainide, regular feeding patterns are paramount to achieve a steady therapeutic state, as milk and dairy products are known to reduce the absorption of flecainide. This case series details four milk-fed infants admitted with ECG changes secondary to flecainide toxicity.


Assuntos
Flecainida , Leite , Adulto , Criança , Recém-Nascido , Lactente , Humanos , Pré-Escolar , Animais , Flecainida/uso terapêutico , Eletrocardiografia , Antiarrítmicos/toxicidade , Arritmias Cardíacas/induzido quimicamente
2.
Ann Thorac Surg ; 112(3): e165-e168, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33497660

RESUMO

The use of Melody valves in the mitral position has been introduced in clinical practice. Stent fracture is a recognized complication of Melody valve implantation in the pulmonary position; however, reports in the mitral position are rare. We present the case of an 8-year-old boy in whom complete fracture of the proximal stent struts occurred, causing acute severe mitral stenosis, and in whom urgent hybrid transapical Melody valve implantation in the fractured Melody valve was performed successfully using a novel modified technique. This modification simplified the implantation, led to reduced time of the procedure, and minimized hemodynamic instability.


Assuntos
Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Estenose da Valva Mitral/etiologia , Falha de Prótese/efeitos adversos , Criança , Humanos , Masculino
3.
Nano Lett ; 12(11): 5598-602, 2012 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-23025816

RESUMO

Surface plasmon has the unique capability to concentrate light into subwavelength volume. Active plasmon devices using electrostatic gating can enable flexible control of the plasmon excitations, which has been demonstrated recently in terahertz plasmonic structures. Controlling plasmon resonance at optical frequencies, however, remains a significant challenge because gate-induced free electrons have very weak responses at optical frequencies. Here we achieve efficient control of near-infrared plasmon resonance in a hybrid graphene-gold nanorod system. Exploiting the uniquely strong and gate-tunable optical transitions of graphene, we are able to significantly modulate both the resonance frequency and quality factor of gold nanorod plasmon. Our analysis shows that the plasmon-graphene coupling is remarkably strong: even a single electron in graphene at the plasmonic hotspot could have an observable effect on plasmon scattering intensity. Such hybrid graphene-nanometallic structure provides a powerful way for electrical control of plasmon resonances at optical frequencies and could enable novel plasmonic sensing down to single charge transfer events.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...