Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Circulation ; 114(8): 759-65, 2006 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-16908760

RESUMO

BACKGROUND: In patients with atrial fibrillation (AF), the risk of thromboembolic events (TEs) is variable and is influenced by the presence and number of comorbid conditions. The effect of percutaneous left atrial radiofrequency ablation (LARFA) of AF on the risk of TEs is unclear. METHODS AND RESULTS: LARFA was performed in 755 consecutive patients with paroxysmal (n = 490) or chronic (n = 265) AF. Four hundred eleven patients (56%) had > or = 1 risk factor for stroke. All patients were anticoagulated with warfarin for > or = 3 months after LARFA. A TE occurred in 7 patients (0.9%) within 2 weeks of LARFA. A late TE occurred 6 to 10 months after ablation in 2 patients (0.2%), 1 of whom still had AF, despite therapeutic anticoagulation in both. Among 522 patients who remained in sinus rhythm after LARFA, warfarin was discontinued in 79% of 256 patients without risk factors and in 68% of 266 patients with > or = 1 risk factor. Patients older than 65 years or with a history of stroke were more likely to remain anticoagulated despite a successful outcome from LARFA. None of the patients in whom anticoagulation was discontinued had a TE during 25 +/- 8 months of follow-up. CONCLUSIONS: The risk of a TE after LARFA is 1.1%, with most events occurring within 2 weeks after the procedure. Discontinuation of anticoagulant therapy appears to be safe after successful LARFA, both in patients without risk factors for stroke and in patients with risk factors other than age > 65 years and history of stroke. Sufficient safety data are as yet unavailable to support discontinuation of anticoagulation in patients older than 65 years or with a history of stroke.


Assuntos
Fibrilação Atrial/terapia , Ablação por Cateter/efeitos adversos , Tromboembolia/epidemiologia , Idoso , Feminino , Seguimentos , Heparina/farmacologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Acidente Vascular Cerebral/epidemiologia , Fatores de Tempo , Resultado do Tratamento
2.
J Am Coll Cardiol ; 48(2): 340-8, 2006 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-16843185

RESUMO

OBJECTIVES: The aim of this study was to determine the effects of circumferential pulmonary vein ablation (CPVA) and electrogram-guided ablation (EGA) on the spectral characteristics of atrial fibrillation (AF) and the relationship between changes in dominant frequency (DF) and clinical outcome. BACKGROUND: Circumferential pulmonary vein ablation and EGA have been used to eliminate AF. Spectral analysis may identify high-frequency sources. METHODS: In 84 consecutive patients, CPVA (n = 42) or EGA (n = 42) was performed for paroxysmal (n = 49) or persistent (n = 35) AF. During EGA, complex electrograms were targeted. Lead V1 and electrograms from the left atrium and coronary sinus were analyzed to determine the DF of AF before and after ablation. RESULTS: The left atrial DF was higher in persistent (5.83 +/- 0.86 Hz) than paroxysmal AF (5.33 +/- 0.76 Hz, p = 0.03). There was a frequency gradient from the left atrium to the coronary sinus (p = 0.02). Circumferential pulmonary vein ablation and EGA resulted in a similar decrease in DF (18 +/- 17% vs. 17 +/- 15%, p = 0.8). During a mean follow-up of 9 +/- 6 months, the change in DF after CPVA was similar among patients with and without recurrent AF. An acute decrease in DF after EGA was associated with freedom from recurrent AF only in patients with persistent AF (19 +/- 14% vs. 3 +/- 6%, p = 0.02). CONCLUSIONS: Both CPVA and EGA decrease the DF of AF, consistent with elimination of high-frequency sources. Whereas the efficacy of EGA is associated with a decrease in DF in patients with persistent AF, the efficacy of CPVA is independent of changes in DF. This suggests that CPVA and EGA eliminate different mechanisms in the genesis of persistent AF.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Idoso , Técnicas Eletrofisiológicas Cardíacas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Processamento de Sinais Assistido por Computador , Espectroscopia de Infravermelho com Transformada de Fourier
3.
Circulation ; 113(5): 609-15, 2006 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-16461832

RESUMO

BACKGROUND: Patients who have previously undergone ablation of atrial fibrillation may experience cavotricuspid isthmus (CTI)-dependent atrial flutter during follow-up. The effects of left atrial (LA) ablation on the characteristics of CTI-dependent flutter have not been described. METHODS AND RESULTS: Fifteen patients underwent ablation of CTI-dependent flutter late after LA ablation of AF. The ECG, biatrial activation patterns, and LA voltage maps during flutter were analyzed. Thirty age- and gender-matched patients who underwent ablation of CTI-dependent flutter without prior LA ablation served as control subjects. Among the patients with prior LA ablation, mapping revealed counterclockwise activation around the tricuspid annulus in 12 of 15 patients (80%) and clockwise activation in 3 of 15 patients (20%). The flutter waves in the inferior leads were upright in 9 of the 15 patients (60%) with prior LA ablation and in none of the control subjects (P<0.001). The upright flutter waves in the inferior leads in patients with counterclockwise flutter corresponded to craniocaudal activation of the right atrial free wall. LA activation contributed little to the genesis of the flutter waves in these patients because of a significant reduction in bipolar LA voltage (0.44+/-0.20 versus 1.54+/-0.19 mV in patients with biphasic/negative flutter waves; P<0.001). CONCLUSIONS: CTI-dependent flutter that occurs after LA ablation of atrial fibrillation often has atypical ECG characteristics because of altered LA activation. In patients presenting with atrial flutter after LA ablation, entrainment mapping should be performed at the CTI even if the ECG is uncharacteristic of CTI-dependent flutter.


Assuntos
Fibrilação Atrial/terapia , Flutter Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Valva Tricúspide/fisiopatologia , Fibrilação Atrial/complicações , Flutter Atrial/etiologia , Mapeamento Potencial de Superfície Corporal , Eletrocardiografia , Feminino , Átrios do Coração/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade
4.
J Am Coll Cardiol ; 46(11): 2107-10, 2005 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-16325049

RESUMO

OBJECTIVES: The aim of this study was to describe the extent of esophageal mobility that occurs during catheter ablation for atrial fibrillation under conscious sedation. BACKGROUND: Ablation along the posterior left atrium may cause an atrioesophageal fistula. One strategy for avoiding this risk is to not deliver radiofrequency energy at sites in contact with the esophagus. METHODS: In 51 consecutive patients with atrial fibrillation who underwent left atrial ablation under conscious sedation, digital cine-fluoroscopic imaging of the esophagus was performed in two views after ingestion of barium paste at the beginning and end of the ablation procedure. Movement of the esophagus was determined at the superior, mid-, and inferior parts of the posterior left atrium in reference to the spine. RESULTS: Mean esophageal movement was 2.0 +/- 0.8 cm (range = 0.3 to 3.8 cm) at the superior, 1.7 +/- 0.8 cm (range = 0.1 to 3.5 cm) at the mid-, and 2.1 +/- 1.2 cm (range = 0.1 to 4.5 cm) at the inferior levels. In 67% of the 51 patients, the esophagus shifted by > or =2 cm, and in 4% there was > or =4 cm of lateral movement. The mean change in esophageal luminal width was 5 +/- 7 mm (range = 0 to 36 mm) at the superior, 5 +/- 7 mm (range = 0 to 32 mm) at the mid-, and 6 +/- 7 mm (range = 0 to 21 mm) at the inferior levels of the posterior left atrium. CONCLUSIONS: The esophagus often is mobile and shifts sideways by > or=2 cm in a majority of patients undergoing catheter ablation for atrial fibrillation under conscious sedation. Therefore, real-time imaging of the esophagus may be helpful in reducing the risk of esophageal injury during radiofrequency ablation along the posterior left atrium.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Esôfago/fisiopatologia , Movimento , Sedação Consciente , Fístula Esofágica/etiologia , Feminino , Fístula/etiologia , Fluoroscopia , Átrios do Coração , Cardiopatias/etiologia , Humanos , Masculino , Pessoa de Meia-Idade
5.
Heart Rhythm ; 2(9): 923-8, 2005 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16171744

RESUMO

BACKGROUND: The effects of left atrial (LA) circumferential ablation on LA function in patients with atrial fibrillation (AF) have not been well described. OBJECTIVES: The purpose of this study was to determine the effect of LA circumferential ablation on LA function. METHODS: Gated, multiphase, dynamic contrast-enhanced computed tomographic (CT) scans of the chest with three-dimensional reconstructions of the heart were used to calculate the LA ejection fraction (EF) in 36 patients with paroxysmal (n = 27) or chronic (n = 9) AF (mean age 55 +/- 11 years) and in 10 control subjects with no history of AF. Because CT scans had to be acquired during sinus rhythm, a CT scan was available both before and after (mean 5 +/- 1 months) LA circumferential ablation (LACA) in only 10 patients. A single CT scan was acquired in 8 patients before and in 18 patients after LACA ablation. Radiofrequency catheter ablation was performed using an 8-mm-tip catheter to encircle the pulmonary veins, with additional lines along the mitral isthmus and the roof. RESULTS: In patients with paroxysmal AF, LA EF was lower after than before LACA (21% +/- 8% vs 32 +/- 13%, P = .003). LA EF after LA catheter ablation was similar among patients with paroxysmal AF and those with chronic AF (21% +/- 8% vs 23 +/- 13%, P = .7). However, LA EF after LA catheter ablation was lower in all patients with AF than in control subjects (21% +/- 10% vs 47% +/- 5%, P < .001). CONCLUSION: During medium-term follow-up, restoration of sinus rhythm by LACA results in partial return of LA function in patients with chronic AF. However, in patients with paroxysmal AF, LA catheter ablation results in decreased LA function. Whether the impairment in LA function is severe enough to predispose to LA thrombi despite elimination of AF remains to be determined.


Assuntos
Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Função do Átrio Esquerdo , Ablação por Cateter , Adulto , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/diagnóstico por imagem , Estudos de Casos e Controles , Doença Crônica , Técnicas Eletrofisiológicas Cardíacas , Feminino , Seguimentos , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/fisiopatologia , Átrios do Coração/cirurgia , Sistema de Condução Cardíaco/diagnóstico por imagem , Sistema de Condução Cardíaco/fisiopatologia , Sistema de Condução Cardíaco/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Volume Sistólico , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento
6.
J Am Coll Cardiol ; 46(1): 83-91, 2005 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-15992640

RESUMO

OBJECTIVES: The goal of this study was to describe the prevalence and ablation of coronary sinus (CS) arrhythmias after left atrial ablation for atrial fibrillation (AF). BACKGROUND: The CS has been implicated in a variety of supraventricular arrhythmias. METHODS: Thirty-eight patients underwent mapping and ablation of atypical flutter that developed during (n = 5) or after (n = 33) ablation for AF. Also included were two patients with focal CS arrhythmias that occurred during an AF ablation procedure. A tachycardia was considered to be originating from the CS if the post-pacing interval in the CS matched the tachycardia cycle length and/or if it terminated during ablation in the CS. RESULTS: Among the 33 patients who developed atypical flutter late after AF ablation, 9 (27%) were found to have a CS origin. Overall, 16 of the 40 patients in this study had a CS arrhythmia. The tachycardia was macro-re-entrant in 14 patients (88%) and focal in two patients. Radiofrequency ablation with an 8-mm-tip catheter was successful in 15 patients (94%) without complication. In eight patients (50%), > or = 45 W was required for successful ablation. Thirteen of the 15 patients (87%) with a successful ablation acutely remained arrhythmia-free during 5 +/- 5 months of follow-up. CONCLUSIONS: The musculature of the CS serves as a critical component of the re-entry circuit in approximately 25% of patients with atypical flutter after ablation for AF. The CS may also generate focal atrial arrhythmias that may play a role in triggering and/or maintaining AF. Catheter ablation of these arrhythmias in the CS can be performed safely.


Assuntos
Arritmia Sinusal/etiologia , Arritmia Sinusal/cirurgia , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Nó Sinoatrial/fisiopatologia , Nó Sinoatrial/cirurgia , Arritmia Sinusal/fisiopatologia , Eletrocardiografia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Resultado do Tratamento
7.
Heart Rhythm ; 2(7): 694-9, 2005 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15992723

RESUMO

BACKGROUND: The coronary sinus (CS) and its branches may play a role in the genesis of various arrhythmias. Applications of radiofrequency energy within the CS may be necessary. Atrio-esophageal fistula has been recognized as a complication of ablation along the posterior left atrial wall. OBJECTIVES: The purpose of this study was to describe the in vivo topographic anatomy of the CS, esophagus, and coronary arteries using computed tomography (CT). METHODS: Helical contrast CT of the heart with three-dimensional and endoscopic reconstructions was performed in 50 patients (28 men and 22 women; mean age 54 +/- 10 years). The images were reformatted to determine the relationships among the CS, adjacent blood vessels, and esophagus and to determine the nature and thickness of surrounding tissue layers. RESULTS: Mean CS ostium diameter was 12 +/- 4 mm, and mean thickness of the periosteal fat layer was 3 +/- 2 mm. In 40 of the 50 patients (80%), the esophagus was adjacent to the CS, starting 24 +/- 9 mm from the ostium, and remained in contact for a mean length of 7 +/- 5 mm. Mean thickness of the fat layer between the esophagus and CS was 1 +/- 1 mm, and mean thickness of the anterior wall of the esophagus was 3 +/- 2 mm. In 10 patients (20%), there was no contact between the esophagus and CS. In 40 patients (80%), the right coronary artery was less than 5 mm from the CS (minimum distance 1 +/- 1 mm) over a mean length of 17 +/- 11 mm. In all patients, the circumflex artery was less than 5 mm from the CS (minimum distance 1 +/- 0.4 mm) over a mean length of 16 +/- 9 mm in patients with right-dominant coronary circulation and over a mean length of 86 +/- 11 mm in patients with left-dominant coronary circulation. CONCLUSION: The CS often lies very close to the esophagus and coronary arteries. During radiofrequency energy ablation in the CS, caution should be exercised to prevent injury to surrounding structures.


Assuntos
Aneurisma da Aorta Torácica/diagnóstico por imagem , Fibrilação Atrial/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/patologia , Adulto , Aneurisma da Aorta Torácica/patologia , Aneurisma da Aorta Torácica/fisiopatologia , Fibrilação Atrial/patologia , Fibrilação Atrial/fisiopatologia , Doença da Artéria Coronariana/patologia , Doença da Artéria Coronariana/fisiopatologia , Circulação Coronária/fisiologia , Vasos Coronários/fisiopatologia , Eletrocardiografia , Esôfago/diagnóstico por imagem , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada Espiral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...