1.
Unfallchirurgie (Heidelb) ; 126(3): 238-243, 2023 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-35476023

RESUMO

Following fixation of a trochanteric femoral fracture with a TFNA© and despite correct fracture reduction and fixation, a 96-year-old patient suffered a complete cut-in, i.e. a medialization of the entire femoral neck blade through the nail into the hip joint. Against the background of implant development and current literature, this increasingly frequent type of complication is described and distinguished from other fixation failures such as the cut-out. Attempts to explain this phenomenon as well as research options are presented and a pragmatic approach to avoid this problem is outlined.


Assuntos
Colo do Fêmur , Fraturas do Quadril , Humanos , Idoso de 80 Anos ou mais , Pinos Ortopédicos , Fraturas do Quadril/diagnóstico por imagem , Fixação Interna de Fraturas , Articulação do Quadril