Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Acta Radiol ; 49(2): 157-66, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18300139

RESUMO

BACKGROUND: Radiographic examinations of the skeleton are the most commonly performed radiologic procedures, even outnumbering examinations of the chest. The imaging systems used in skeletal radiography must meet high standards in terms of contrast and spatial resolution to effectively visualize the high contrast between bone and soft tissue as well as fine bone structures. PURPOSE: To determine the performance of amorphous silicon flat-panel detector radiography compared to mammography film in detecting rheumatologic bone defects at different exposure doses. MATERIAL AND METHODS: The study enrolled 44 patients with known or presumed skeletal changes of the hand associated with inflammatory rheumatic diseases. Following a clinically indicated radiographic examination of the peripheral extremities using mammography film, a survey radiograph of one hand was taken in the posteroanterior (PA) view by digital radiography, at the same exposure dose and at a dose reduced to one quarter of the mammography film doses. Four independent radiologists scored the resultant images using the Sharp/van der Heijde and Ratingen scoring methods. The study received University of Cologne Ethics Committee and German Federal Radiation Protection Agency approval. RESULTS: Compared to mammography film, digital flat-panel detector radiography produced a significantly better image quality at identical uptake doses. A greater number of erosions were detected with the digital flat-panel detector than with mammography film at the same and at reduced doses. CONCLUSION: Although the spatial resolution of the digital flat-panel system used in this study was poorer than mammography film, this was compensated for by its wider dynamic range and improved contrast resolution, even at the reduced dose.


Assuntos
Mãos/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Doenças Reumáticas/diagnóstico , Ecrans Intensificadores para Raios X , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Doses de Radiação , Reprodutibilidade dos Testes , Compostos de Silício , Ultrassonografia
3.
J Pathol ; 153(2): 183-7, 1987 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-3694323

RESUMO

Dimethyl sulphoxide (DMSO), 3 g/kg body weight, administered daily by the intraperitoneal route, potentiated the proteinuria and formation of tubular casts in aminonucleoside of puromycin (PA) induced nephrosis in Sprague-Dawley rats. The effect was evident at 4 as well as 8-9 days following PA administration. In the absence of PA, DMSO did not induce proteinuria or cast formation. The mechanism by which DMSO enhanced proteinuria and cast formation is not known.


Assuntos
Dimetil Sulfóxido/farmacologia , Nefrose Lipoide/induzido quimicamente , Puromicina Aminonucleosídeo/toxicidade , Puromicina/análogos & derivados , Animais , Sinergismo Farmacológico , Rim/patologia , Masculino , Nefrose Lipoide/patologia , Proteinúria/induzido quimicamente , Ratos , Ratos Endogâmicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...