Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Surg Innov ; 22(6): 643-50, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25733547

RESUMO

PURPOSE: Though already proclaimed about 7 years ago, natural orifice transluminal endoscopic surgery (NOTES) is still in its early stages. A multidisciplinary working team tried to analyze the technical obstacles and identify potential solutions. METHODS: After a comprehensive review of the literature, a group of 3 surgeons, 1 gastroenterologist, 10 engineers, and 1 representative of biomedical industry defined the most important deficiencies within the system and then compiled as well as evaluated innovative technologies that could be used to help overcome these problems. These technologies were classified with regard to the time needed for their implementation and associated hindrances, where priority is based on the level of impact and significance that it would make. RESULTS: Both visualization and actuation require significant improvement. Advanced illumination, mist elimination, image stabilization, view extension, 3-dimensional stereoscopy, and augmented reality are feasible options and could optimize visual information. Advanced mechatronic platforms with miniaturized, powerful actuators, and intuitive human-machine interfaces could optimize dexterity, as long as enabling technologies are used. The latter include depth maps in real time, precise navigation, fast pattern recognition, partial autonomy, and cognition systems. CONCLUSION: The majority of functional deficiencies that still exist in NOTES platforms could be overcome by a broad range of already existing or emerging enabling technologies. To combine them in an optimal manner, a permanent dialogue between researchers and clinicians is mandatory.


Assuntos
Cirurgia Endoscópica por Orifício Natural , Procedimentos Cirúrgicos Robóticos , Humanos
2.
Surg Innov ; 22(4): 432-40, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25249584

RESUMO

PURPOSE: To investigate why natural orifice translumenal endoscopic surgery (NOTES) has not yet become widely accepted and to prove whether the main reason is still the lack of appropriate platforms due to the deficiency of applicable interfaces. METHODS: To assess expectations of a suitable interface design, we performed a survey on human-machine interfaces for NOTES mechatronic support systems among surgeons, gastroenterologists, and medical engineers. Of 120 distributed questionnaires, each consisting of 14 distinct questions, 100 (83%) were eligible for analysis. RESULTS: A mechatronic platform for NOTES was considered "important" by 71% of surgeons, 83% of gastroenterologist,s and 56% of medical engineers. "Intuitivity" and "simple to use" were the most favored aspects (33% to 51%). Haptic feedback was considered "important" by 70% of participants. In all, 53% of surgeons, 50% of gastroenterologists, and 33% of medical engineers already had experience with NOTES platforms or other surgical robots; however, current interfaces only met expectations in just more than 50%. Whereas surgeons did not favor a certain working posture, gastroenterologists and medical engineers preferred a sitting position. Three-dimensional visualization was generally considered "nice to have" (67% to 72%); however, for 26% of surgeons, 17% of gastroenterologists, and 7% of medical engineers it did not matter (P = 0.018). CONCLUSION: Requests and expectations of human-machine interfaces for NOTES seem to be generally similar for surgeons, gastroenterologist, and medical engineers. Consensus exists on the importance of developing interfaces that should be both intuitive and simple to use, are similar to preexisting familiar instruments, and exceed current available systems.


Assuntos
Sistemas Homem-Máquina , Cirurgia Endoscópica por Orifício Natural/instrumentação , Procedimentos Cirúrgicos Robóticos/instrumentação , Adulto , Engenharia Biomédica , Estudos Transversais , Feminino , Gastroenterologia , Humanos , Masculino , Pessoa de Meia-Idade , Cirurgiões/psicologia , Cirurgiões/estatística & dados numéricos , Inquéritos e Questionários
3.
Int J Comput Assist Radiol Surg ; 9(6): 941-8, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24558003

RESUMO

PURPOSE: Laparoscopic cholecystectomy is a very common minimally invasive surgical procedure that may be improved by autonomous or cooperative assistance support systems. Model-based surgery with a precise definition of distinct procedural tasks (PT) of the operation was implemented and tested to depict and analyze the process of this procedure. METHODS: Reliability of real-time workflow recognition in laparoscopic cholecystectomy ([Formula: see text] cases) was evaluated by continuous sensor-based data acquisition. Ten PTs were defined including begin/end preparation calots' triangle, clipping/cutting cystic artery and duct, begin/end gallbladder dissection, begin/end hemostasis, gallbladder removal, and end of operation. Data acquisition was achieved with continuous instrument detection, room/table light status, intra-abdominal pressure, table tilt, irrigation/aspiration volume and coagulation/cutting current application. Two independent observers recorded start and endpoint of each step by analysis of the sensor data. The data were cross-checked with laparoscopic video recordings serving as gold standard for PT identification. RESULTS: Bland-Altman analysis revealed for 95% of cases a difference of annotation results within the limits of agreement ranging from [Formula: see text]309 s (PT 7) to +368 s (PT 5). Laparoscopic video and sensor data matched to a greater or lesser extent within the different procedural tasks. In the majority of cases, the observer results exceeded those obtained from the laparoscopic video. Empirical knowledge was required to detect phase transit. CONCLUSIONS: A set of sensors used to monitor laparoscopic cholecystectomy procedures was sufficient to enable expert observers to reliably identify each PT. In the future, computer systems may automate the task identification process provided a more robust data inflow is available.


Assuntos
Colecistectomia Laparoscópica/métodos , Fluxo de Trabalho , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos , Reprodutibilidade dos Testes , Resultado do Tratamento
4.
Endoscopy ; 46(4): 302-5, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24254384

RESUMO

BACKGROUND AND STUDY AIMS: For preoperative work-up, an examination tool that visualizes separately compiled diagnostics in augmented reality would be desirable. We developed a probe-based electromagnetic navigation system, which can be passed through the working channel of an endoscope, to integrate computed tomography (CT) information during upper gastrointestinal endoscopy. PATIENTS AND METHODS: The target registration error (TRE) of the system was evaluated experimentally and clinically. A total of 24 study patients with upper gastrointestinal cancer were included in the study. The cancerous lesion was endoscopically located (mean duration 8.4 minutes, range 7.1 - 23.2) and the TRE (coronal, transverse, sagittal layer) was measured by comparing the distance between the navigation probe (at the tip of the endoscope) and the target lesion shown on the corresponding CT cross section. RESULTS: Experimental evaluations showed an accuracy in line with the system's inherent failure rate, with a median TRE of 2.8 mm (IQR 1.8 - 4.3), 2.2 mm (0.4 - 3.7), and 2.8 mm (1.1 - 5.9) in the coronal, transverse, and sagittal planes, respectively. Clinical evaluation revealed a median TRE of 4.8 mm (1.9 - 10.1), 3.9 mm (0.7 - 7.1), and 4.2 mm (0.9 - 8.9), respectively. No complications occurred during navigated endoscopy. CONCLUSIONS: The probe-based electromagnetic navigation system revealed high accuracy (TRE < 5 mm), facilitating improved interpretation of endoluminal imaging.


Assuntos
Fenômenos Eletromagnéticos , Endoscopia Gastrointestinal/métodos , Neoplasias Gastrointestinais/diagnóstico , Tomografia Computadorizada por Raios X/métodos , Idoso , Estudos de Coortes , Feminino , Neoplasias Gastrointestinais/diagnóstico por imagem , Neoplasias Gastrointestinais/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Imagem Multimodal/instrumentação , Cuidados Pré-Operatórios/métodos , Sensibilidade e Especificidade
5.
J Surg Res ; 185(2): 704-10, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23859134

RESUMO

BACKGROUND: A key part of surgical workflow recording is recognition of the instrument in use. We present a radiofrequency identification (RFID)-based approach for real-time tracking of laparoscopic instruments. METHODS: The system consists of RFID-tagged instruments and an antenna unit positioned on the Mayo stand. For reliability analysis, RFID tracking data were compared with the assessment of the perioperative video data of instrument changes (the reference standard for instrument application detection) in 10 laparoscopic cholecystectomies. When the tagged instrument was on the Mayo stand, it was referred to as "not in use." Once it was handed to the surgeon, it was considered to be "in use." Temporal miscounts (incorrect number of instruments "in use") were analyzed. The surgeons and scrub nurses completed a questionnaire after each operation for individual system evaluation. RESULTS: A total of 110 distinct instrument applications ("in use" versus "not in use") were eligible for analysis. No RFID tag failure occurred. The RFID detection rates were consistent with the period of effective instrument application. The delay in instrument detection was 4.2 ± 1.7 s. The highest percentage of temporal miscounts occurred during phases with continuous application of coagulation current. Surgeons generally rated the system better than the scrub nurses (P = 0.54). CONCLUSIONS: The feasibility of RFID-based real-time instrument detection was successfully proved in our study, with reliable detection results during laparoscopic cholecystectomy. Thus, RFID technology has the potential to be a valuable additional tool for surgical workflow recognition that could enable a situation dependent assistance of the surgeon in the future.


Assuntos
Colecistectomia Laparoscópica/instrumentação , Colecistectomia Laparoscópica/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Dispositivo de Identificação por Radiofrequência/métodos , Instrumentos Cirúrgicos , Adulto , Idoso , Colecistectomia Laparoscópica/enfermagem , Estudos de Viabilidade , Feminino , Humanos , Período Intraoperatório , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/enfermagem , Enfermagem de Centro Cirúrgico , Salas Cirúrgicas , Reprodutibilidade dos Testes , Fluxo de Trabalho
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...