Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Gut Microbes ; 13(1): 1-21, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33870860

RESUMO

Colonization and maturation of the gut microbiota (GM) during early life is a landmark event that fundamentally influences the (early) immunity and later-life health of various mammals. This is a delicate, systematic process that is biologically actively regulated by infants and their mothers, where (secretory) IgA, an important regulator of microbes found in breast milk and generated actively by infants, may play a key role. By binding to microbes, IgA can inhibit or enhance their colonization, influence their gene expression, and regulate immune responses. IgA dysfunction during early life is associated with disrupted GM maturation and various microbe-related diseases, such as necrotizing enterocolitis and diarrhea, which can also have a lasting effect on GM and host health. This review discusses the process of early GM maturation and its interaction with immunity and the role of IgA (focusing on milk secretory IgA) in regulating this process. The possible application of this knowledge in promoting normal GM maturation processes and immune education has also been highlighted.


Assuntos
Microbioma Gastrointestinal , Imunidade , Imunoglobulina A Secretora/fisiologia , Leite Humano/imunologia , Aleitamento Materno , Feminino , Humanos , Lactente , Recém-Nascido , Oligossacarídeos/imunologia
2.
Artigo em Inglês | MEDLINE | ID: mdl-30243116

RESUMO

Short-chain fatty acids (SCFAs) in the gut are mainly produced by the anaerobic microbial fermentation of unabsorbed dietary carbohydrates in the large bowel. Quantitative determinations of SCFAs in feces and colonic contents are necessary when studying the impact of fiber-rich food (such as fruits and vegetables) on health. We made the following crucial improvements to the method currently widely used: optimized the lyophilization period from 12 h to 3.5 h; disposed of the procedure for precise weight control; lowered the extraction temperature from 25 °C to 4 °C; shortened the extraction time from 45 min to 15 min; and significantly improved the extraction efficiency of acetic acid, propionic acid and butyric acid by 12.91%, 19.95% and 13.08%, respectively. Furthermore, to evaluate the applicability of this novel approach, we applied our method to determine the SCFAs in the feces and colonic contents of mice fed on different diets, and observed distinct results.


Assuntos
Ácidos Graxos Voláteis/análise , Fezes/química , Cromatografia Gasosa-Espectrometria de Massas/métodos , Animais , Limite de Detecção , Modelos Lineares , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Reprodutibilidade dos Testes
3.
Food Funct ; 9(8): 4366-4375, 2018 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-30043820

RESUMO

Anthocyanins have a positive effect on resistant obesity; however they cannot usually be absorbed directly but, instead, are metabolized by gut microbiota. This study will examine the effects and the mechanism of vanillic acid on the prevention of obesity induced by diet, which is one of the anthocyanin metabolites. We fed C57BL/6J mice vanillic acid supplements in a high fat and high fructose diet for 16 weeks. Body weight, fat pat weight, and food and water intake were monitored. Glucose homeostasis was assessed with a glucose or insulin tolerance test. The sizes of adipose cells and lipid droplets were analyzed by histology staining, while the expression of genes and proteins was analyzed by quantitative real-time PCR, western blot and tissue-blot immunoassay. The results demonstrated that vanillic acid contributed to the reduction of body weight gain, improved glucose tolerance and insulin resistance, and maintained body temperature. Furthermore, vanillic acid was found to promote thermogenesis and mitochondrial synthesis of brown adipose tissue and inguinal white adipose tissue. This study demonstrated that vanillic acid could prevent obesity by activating BAT thermogenesis and the promotion of inguinal WAT browning.


Assuntos
Tecido Adiposo Marrom/efeitos dos fármacos , Tecido Adiposo Branco/efeitos dos fármacos , Obesidade/tratamento farmacológico , Termogênese/efeitos dos fármacos , Ácido Vanílico/farmacologia , Tecido Adiposo Marrom/metabolismo , Tecido Adiposo Branco/metabolismo , Animais , Peso Corporal/efeitos dos fármacos , Metabolismo Energético/efeitos dos fármacos , Humanos , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Obesidade/metabolismo , Obesidade/fisiopatologia
4.
Br J Radiol ; 91(1081): 20170521, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29076347

RESUMO

OBJECTIVE: To evaluate the image quality improvement and noise reduction in routine dose, non-enhanced chest CT imaging by using a new generation adaptive statistical iterative reconstruction (ASIR-V) in comparison with ASIR algorithm. METHODS: 30 patients who underwent routine dose, non-enhanced chest CT using GE Discovery CT750HU (GE Healthcare, Waukesha, WI) were included. The scan parameters included tube voltage of 120 kVp, automatic tube current modulation to obtain a noise index of 14HU, rotation speed of 0.6 s, pitch of 1.375:1 and slice thickness of 5 mm. After scanning, all scans were reconstructed with the recommended level of 40%ASIR for comparison purpose and different percentages of ASIR-V from 10% to 100% in a 10% increment. The CT attenuation values and SD of the subcutaneous fat, back muscle and descending aorta were measured at the level of tracheal carina of all reconstructed images. The signal-to-noise ratio (SNR) was calculated with SD representing image noise. The subjective image quality was independently evaluated by two experienced radiologists. RESULTS: For all ASIR-V images, the objective image noise (SD) of fat, muscle and aorta decreased and SNR increased along with increasing ASIR-V percentage. The SD of 30% ASIR-V to 100% ASIR-V was significantly lower than that of 40% ASIR (p < 0.05). In terms of subjective image evaluation, all ASIR-V reconstructions had good diagnostic acceptability. However, the 50% ASIR-V to 70% ASIR-V series showed significantly superior visibility of small structures when compared with the 40% ASIR and ASIR-V of other percentages (p < 0.05), and 60% ASIR-V was the best series of all ASIR-V images, with a highest subjective image quality. The image sharpness was significantly decreased in images reconstructed by 80% ASIR-V and higher. CONCLUSION: In routine dose, non-enhanced chest CT, ASIR-V shows greater potential in reducing image noise and artefacts and maintaining image sharpness when compared to the recommended level of 40%ASIR algorithm. Combining both the objective and subjective evaluation of images, non-enhanced chest CT images reconstructed with 60% ASIR-V have the highest image quality. Advances in knowledge: This is the first clinical study to evaluate the clinical value of ASIR-V in the same patients using the same CT scanner in the non-enhanced chest CT scans. It suggests that ASIR-V provides the better image quality and higher diagnostic confidence in comparison with ASIR algorithm.


Assuntos
Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Torácica/métodos , Tomografia Computadorizada por Raios X/métodos , Artefatos , Humanos , Melhoria de Qualidade , Doses de Radiação
5.
Eur J Radiol ; 95: 222-227, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28987671

RESUMO

OBJECTIVE: To study the clinical value of dual-energy spectral CT in the quantitative assessment of microvascular invasion of small hepatocellular carcinoma. METHODS: This study was approved by our ethics committee. 50 patients with small hepatocellular carcinoma who underwent contrast enhanced spectral CT in arterial phase (AP) and portal venous phase (VP) were enrolled. Tumour CT value and iodine concentration (IC) were measured from spectral CT images. The slope of spectral curve, normalized iodine concentration (NIC, to abdominal aorta) and ratio of IC difference between AP and VP (RICAP-VP: [RICAP-VP=(ICAP-ICVP)/ICAP]) were calculated. Tumours were identified as either with or without microvascular invasion based on pathological results. Measurements were statistically compared using independent samples t test. The receiver operating characteristic (ROC) analysis was used to evaluate the diagnostic performance of tumours microvascular invasion assessment. The 70keV images were used to simulate the results of conventional CT scans for comparison. RESULTS: 56 small hepatocellular carcinomas were detected with 37 lesions (Group A) with microvascular invasion and 19 (Group B) without. There were significant differences in IC, NIC and slope in AP and RICAP-VP between Group A (2.48±0.70mg/ml, 0.23±0.05, 3.39±1.01 and 0.28±0.16) and Group B (1.65±0.47mg/ml, 0.15±0.05, 2.22±0.64 and 0.03±0.24) (all p<0.05). Using 0.188 as the threshold for NIC, one could obtain an area-under-curve (AUC) of 0.87 in ROC to differentiate between tumours with and without microvascular invasion. AUC was 0.71 with CT value at 70keV and improved to 0.81 at 40keV. CONCLUSION: Dual-energy Spectral CT provides additional quantitative parameters than conventional CT to improve the differentiation between small hepatocellular carcinoma with and without microvascular invasion. CLINICAL APPLICATION/RELEVANCE: Quantitative iodine concentration measurement in spectral CT may be used to provide a new method to improve the evaluation for small hepatocellular carcinoma microvascular invasion.


Assuntos
Carcinoma Hepatocelular/irrigação sanguínea , Carcinoma Hepatocelular/diagnóstico por imagem , Neoplasias Hepáticas/irrigação sanguínea , Neoplasias Hepáticas/diagnóstico por imagem , Microvasos/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Absorciometria de Fóton/métodos , Área Sob a Curva , Carcinoma Hepatocelular/patologia , Feminino , Humanos , Fígado/irrigação sanguínea , Fígado/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Masculino , Microvasos/patologia , Pessoa de Meia-Idade , Curva ROC , Reprodutibilidade dos Testes
6.
Mol Nutr Food Res ; 61(11)2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28691397

RESUMO

SCOPE: Obesity develops when energy intake exceeds energy expenditure. Promoting brown adipose tissue (BAT) formation and function increases energy expenditure and may protect against obesity. Cyanidin-3-glucoside (C3G) is an anthocyanin compound that occurs naturally in many fruits and vegetables. In this study, we investigated the effect and mechanism of C3G on the prevention of obesity. METHODS AND RESULTS: Db/db mice received C3G dissolved in drinking water for 16 wk; drinking water served as the vehicle treatment. The total body weight, energy intake, metabolic rate, and physical activity were measured. The lipid droplets, gene expression and protein expression were evaluated by histochemical staining, real-time PCR, and western blots. We found that C3G increased energy expenditure, limited weight gain, maintained glucose homeostasis, reversed hepatic steatosis, improved cold tolerance, and enhanced BAT activity in obese db/db mice. C3G also induces brown-like adipocytes (beige) formation in subcutaneous white adipose tissue (sWAT) of db/db mice model. We also found that C3G potently regulates the transcription of uncoupling protein 1 (UCP1) both in BAT and sWAT through increasing mitochondrial number and function. CONCLUSION: Our results suggest that C3G plays a role in regulating systemic energy balance, which may have potential therapeutic implications for the prevention and control of obesity.


Assuntos
Tecido Adiposo Marrom/metabolismo , Antocianinas/uso terapêutico , Suplementos Nutricionais , Metabolismo Energético , Glucosídeos/uso terapêutico , Mitocôndrias/metabolismo , Obesidade/prevenção & controle , Regulação para Cima , Adipogenia , Tecido Adiposo Marrom/enzimologia , Tecido Adiposo Marrom/ultraestrutura , Tecido Adiposo Branco/enzimologia , Tecido Adiposo Branco/metabolismo , Tecido Adiposo Branco/patologia , Animais , Comportamento Animal , Ingestão de Energia , Regulação da Expressão Gênica , Fígado/enzimologia , Fígado/metabolismo , Fígado/patologia , Locomoção , Masculino , Camundongos Mutantes , Microscopia Eletrônica de Transmissão , Mitocôndrias/enzimologia , Mitocôndrias/ultraestrutura , Hepatopatia Gordurosa não Alcoólica/metabolismo , Hepatopatia Gordurosa não Alcoólica/patologia , Hepatopatia Gordurosa não Alcoólica/prevenção & controle , Obesidade/metabolismo , Obesidade/patologia , Termotolerância , Proteína Desacopladora 1/genética , Proteína Desacopladora 1/metabolismo , Imagem Corporal Total
7.
Br J Radiol ; 90(1073): 20160632, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28281789

RESUMO

OBJECTIVE: To investigate the value of using the quantitative parameters from only the pre-contrast dual-energy spectral CT imaging for distinguishing between parapelvic cyst and hydronephrosis with non-calculous (HNC). METHODS: This retrospective study was approved by the institutional review board. 28 patients with parapelvic cyst and 24 patients with HNC who underwent standard pre-contrast and multiphase contrast-enhanced dual-energy spectral CT imaging were retrospectively identified. The parapelvic cyst and HNC were identified using the contrast-enhanced scans, and their CT number in the 70-keV monochromatic images, effective atomic number (Zeff), iodine concentration (IC) and water concentration in the pre-contrast images were measured. The slope of the spectral curve (λ) was calculated. The difference in the measurements between parapelvic cyst and HNC was statistically analyzed using SPSS® v. 19.0 (IBM Corp., New York, NY; formerly SPSS Inc., Chicago, IL) statistical software. Receiver-operating characteristic analysis was performed to assess the diagnostic performance. RESULTS: The CT numbers in the 70-keV images, Zeff and IC values were statistically different between parapelvic cyst and HNC (all p < 0.05). The sensitivity, specificity and accuracy of these parameters for distinguishing between parapelvic cyst and HNC were 89.2%, 73.3% and 82.1%; 86.5%, 43.3% and 67.2%; 91.9%, 40.0% and 68.7%; and 64.9%, 73.3% and 83.6%, respectively, and the combined specificity was 92.9%. There was no statistical difference in λ between the two groups (p > 0.05). CONCLUSION: The quantitative parameters obtained in the pre-contrast dual-energy spectral CT imaging may be used to differentiate between parapelvic cyst and HNC. Advances in knowledge: The pre-contrast dual-energy spectral CT scans may be used to screen parapelvic cysts for patients who are asymptomatic, thereby avoiding contrast-enhanced CT or CT urography examination for these patients to reduce ionizing radiation dose and contrast dose.


Assuntos
Hidronefrose/diagnóstico por imagem , Doenças Renais Císticas/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Diagnóstico Diferencial , Feminino , Humanos , Rim/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Urografia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...