Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 69
Filtrar
1.
Sensors (Basel) ; 24(11)2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38894358

RESUMO

Simultaneous dual-contrast imaging of iodine and bismuth has shown promise in prior phantom and animal studies utilizing spectral CT. However, it is noted that in previous studies, Pepto-Bismol has frequently been employed as the source of bismuth, exceeding the recommended levels for human subjects. This investigation sought to assess the feasibility of visually differentiating and precisely quantifying low-concentration bismuth using clinical dual-source photon-counting CT (PCCT) in a scenario involving both iodinated and bismuth-based contrast materials. Four bismuth samples (0.6, 1.3, 2.5, and 5.1 mg/mL) were prepared using Pepto-Bismol, alongside three iodine rods (1, 2, and 5 mg/mL), inserted into multi-energy CT phantoms with three different sizes, and scanned on a PCCT system at three tube potentials (120, 140, and Sn140 kV). A generic image-based three-material decomposition method generated iodine and bismuth maps, with mean mass concentrations and noise levels measured. The root-mean-square errors for iodine and bismuth determined the optimal tube potential. The tube potential of 140 kV demonstrated optimal quantification performance when both iodine and bismuth were considered. Distinct differentiation of iodine rods with all three concentrations and bismuth samples with mass concentrations ≥ 1.3 mg/mL was observed across all phantom sizes at the optimal kV setting.


Assuntos
Bismuto , Meios de Contraste , Iodo , Imagens de Fantasmas , Fótons , Tomografia Computadorizada por Raios X , Bismuto/química , Iodo/química , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste/química , Humanos
2.
Radiol Case Rep ; 19(8): 3425-3428, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38881621

RESUMO

We present a case of an 81-year-old woman who presented to the emergency department with bleeding from a right breast wound. The patient had prior imaging suggestive of bilateral silicone implant rupture and a history of low tolerance for MRI scans. Ultrasound imaging in the emergency setting showed findings in the right breast suggestive of a fistula with free silicone and hematoma. A subsequent photon-counting CT scan with custom silicone-specific segmentation allowed differentiation of silicone from hematoma, provided anatomic assessment and location of the fistula, and revealed bilateral silicone-induced lymphadenopathy.

3.
Abdom Radiol (NY) ; 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38744702

RESUMO

Photon counting detector CT (PCD-CT) is the newest major development in CT technology and has been commercially available since 2021. It offers major technological advantages over current standard-of-care energy integrating detector CT (EID-CT) including improved spatial resolution, improved iodine contrast to noise ratio, multi-energy imaging, and reduced noise. This article serves as a foundational basis to the technical approaches and concepts of PCD-CT technology with primary emphasis on detector technology in direct comparison to EID-CT. The article also addresses current technological challenges to PCD-CT with particular attention to cross talk and its causes (e.g., Compton scattering, fluorescence, charge sharing, K-escape) as well as pile-up.

4.
Med Phys ; 51(6): 4231-4242, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38353644

RESUMO

BACKGROUND: Computed tomography (CT) is routinely used to guide cryoablation procedures. Notably, CT-guidance provides 3D localization of cryoprobes and can be used to delineate frozen tissue during ablation. However, metal-induced artifacts from ablation probes can make accurate probe placement challenging and degrade the ice ball conspicuity, which in combination could lead to undertreatment of potentially curable lesions. PURPOSE: In this work, we propose an image-based neural network (CNN) model for metal artifact reduction for CT-guided interventional procedures. METHODS: An image domain metal artifact simulation framework was developed and validated for deep-learning-based metal artifact reduction for interventional oncology (MARIO). CT scans were acquired for 19 different cryoablation probe configurations. The probe configurations varied in the number of probes and the relative orientations. A combination of intensity thresholding and masking based on maximum intensity projections (MIPs) was used to segment both the probes only and probes + artifact in each phantom image. Each of the probe and probe + artifact images were then inserted into 19 unique patient exams, in the image domain, to simulate metal artifact appearance for CT-guided interventional oncology procedures. The resulting 361 pairs of simulated image volumes were partitioned into disjoint training and test datasets of 304 and 57 volumes, respectively. From the training partition, 116 600 image patches with a shape of 128 × 128 × 5 pixels were randomly extracted to be used for training data. The input images consisted of a superposition of the patient and probe + artifact images. The target images consisted of a superposition of the patient and probe only images. This dataset was used to optimize a U-Net type model. The trained model was then applied to 50 independent, previously unseen CT images obtained during renal cryoablations. Three board-certified radiologists with experience in CT-guided ablations performed a blinded review of the MARIO images. A total of 100 images (50 original, 50 MARIO processed) were assessed across different aspects of image quality on a 4-point likert-type item. Statistical analyses were performed using Wilcoxon signed-rank test for paired samples. RESULTS: Reader scores were significantly higher for MARIO processed images compared to the original images across all metrics (all p < 0.001). The average scores of the overall image quality, iceball conspicuity, overall metal artifact, needle tip visualization, target region confidence, and worst metal artifact, needle tip visualization, iceball conspicuity, and target region confidence improved by 34.91%, 36.29%, 39.94%, 34.17%, 35.13%, and 45.70%, respectively. CONCLUSIONS: The proposed method of image-based metal artifact simulation can be used to train a MARIO algorithm to effectively reduce probe-related metal artifacts in CT-guided cryoablation procedures.


Assuntos
Artefatos , Processamento de Imagem Assistida por Computador , Metais , Tomografia Computadorizada por Raios X , Processamento de Imagem Assistida por Computador/métodos , Redes Neurais de Computação , Humanos , Cirurgia Assistida por Computador/métodos , Aprendizado Profundo , Criocirurgia/métodos , Imagens de Fantasmas
5.
Med Phys ; 50(11): 6779-6788, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37669507

RESUMO

BACKGROUND: The feasibility of oral dark contrast media is under exploration in abdominal computed tomography (CT) applications. One of the experimental contrast media in this class is dark borosilicate contrast media (DBCM), which has a CT attenuation lower than that of intra-abdominal fat. PURPOSE: To evaluate the performances of DBCM using single- and multi-energy CT imaging on a clinical photon-counting-detector CT (PCD-CT). METHODS: Five vials, three with iodinated contrast agent (5, 10, and 20 mg/mL; Omnipaque 350) and two with DBCM (6% and 12%; Nextrast, Inc.), and one solid-water rod (neutral contrast agent) were inserted into two multi-energy CT phantoms, and scanned on a clinical PCD-CT system (NAEOTOM Alpha) at 90, 120, 140, Sn100, and Sn140 kV (Sn: tin filter) in multi-energy mode. CARE keV IQ level was 180 (CTDIvol: 3.0 and 12.0 mGy for the small and large phantoms, respectively). Low-energy threshold images were reconstructed with a quantitative kernel (Qr40, iterative reconstruction strength 2) and slice thickness/increment of 2.0/2.0 mm. Virtual monoenergetic images (VMIs) were reconstructed from 40 to 140 keV at 10 keV increments. On all images, average CT numbers for each vial/rod were measured using circular region-of-interests and averaged over eight slices. The contrast-to-noise ratio (CNR) of iodine (5 mg/mL) against DBCM was calculated and plotted against tube potential and VMI energy level, and compared to the CNR of iodine against water. Similar analyses were performed on iodine maps and VNC images derived from the multi-energy scan at 120 kV. RESULTS: With increasing kV or VMI keV, the negative HU of DBCM decreased only slightly, whereas the positive HU of iodine decreased across all contrast concentrations and phantom sizes. CT numbers for DBCM decreased from -178.5 ± 9.6 to -194.4 ± 6.3 HU (small phantom) and from -181.7 ± 15.7 to -192.1 ± 11.9 HU (large phantom) for DBCM-12% from 90 to Sn140 kV; on VMIs, the CT numbers for DBCM decreased minimally from -147.1 ± 15.7 to -185.1 ± 9.2 HU (small phantom) and -158.8 ± 28.6 to -188.9 ± 14.7 HU (large phantom) from 40 to 70 keV, but remained stable from 80 to 140 keV. The highest iodine CNR against DBCM in low-energy threshold images was seen at 90 or Sn140 kV for the small phantom, whereas all CNR values from low-energy threshold images for the large phantom were comparable. The CNR values of iodine against DBCM computed on VMIs were highest at 40 or 70 keV depending on iodine and DBCM concentrations. The CNR values of iodine against DBCM were consistently higher than iodine to water (up to 460% higher dependent on energy level). Further, the CNR of iodine compared to DBCM is less affected by VMI energy level than the identical comparison between iodine and water: CNR values at 140 keV were reduced by 46.6% (small phantom) or 42.6% (large phantom) compared to 40 keV; CNR values for iodine compared to water were reduced by 86.3% and 83.8% for similar phantom sizes, respectively. Compared to 70 keV VMI, the iodine CNR against DBCM was 13%-79% lower on iodine maps and VNC. CONCLUSIONS: When evaluated at different tube potentials and VMI energy levels using a clinical PCD-CT system, DBCM showed consistently higher CNR compared to iodine versus water (a neutral contrast).


Assuntos
Meios de Contraste , Iodo , Tomografia Computadorizada por Raios X/métodos , Iohexol , Imagens de Fantasmas , Água , Razão Sinal-Ruído
6.
Med Phys ; 50(11): 6836-6843, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37650788

RESUMO

BACKGROUND: Coronary calcification is a strong indicator of coronary artery disease, and patients with a "zero" coronary calcification score have a much lower risk of future cardiac events than those with even small amounts of calcium. However, false-negative (incorrect zero scores) may occur if small calcifications are missed at CT due to limited spatial resolution. PURPOSE: To demonstrate lower limits of detection for coronary calcification using an ultra-high-resolution (UHR) mode on a clinical photon-counting-detector CT (PCD-CT), compared to a conventional energy-integrating-detector CT (EID-CT). METHODS: Chicken eggshell fragments (0.4-0.8 mm) mimicking coronary calcifications were scanned on a clinical PCD-CT (NAEOTOM Alpha) in UHR mode and a conventional EID-CT (SOMATOM Force) with matched tube potential and radiation dose levels to the PCD-CT. PCD-CT images were reconstructed with a sharp kernel (Qr68) and a quantum iterative algorithm (QIR-3). Two sets of EID-CT images were reconstructed: routine clinical kernel (Qr36, ADMIRE-3) and a sharper kernel (Qr54) with similar noise to PCD-CT images. With institutional review board approval, in vivo exams performed with the PCD-CT in UHR mode were compared against patients' clinical EID-CT exams. The visibility of calcifications on PCD-CT and EID-CT images was assessed and compared qualitatively. RESULTS: PCD-CT images visualized all calcified fragments, while EID-CT failed to detect those below 0.6 mm using a routine protocol. EID-CT with Qr54 improved visibility but distorted boundaries. Calcifications were less visible on EID-CT than PCD-CT as phantom sizes increased. 0.6- and 0.7-mm calcified fragments were barely visible on 35- and 40-cm phantom EID-CT images. Patient cases showed small calcifications missed on EID-CT but detected on PCD-CT. CONCLUSION: At matched radiation dose, PCD-CT in UHR mode provided higher spatial resolution and improved the detectability of small calcified fragments for different phantom/patient sizes in comparison to EID-CT.


Assuntos
Calcinose , Doença da Artéria Coronariana , Humanos , Fótons , Tomografia Computadorizada por Raios X/métodos , Calcinose/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico por imagem , Doses de Radiação , Imagens de Fantasmas
7.
J Appl Clin Med Phys ; 24(7): e14074, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37335819

RESUMO

PURPOSE: To determine the suitability of a quality assurance (QA) program based on the American College of Radiology's (ACR) CT quality control (QC) manual to fully evaluate the unique capabilities of a clinical photon-counting-detector (PCD) CT system. METHODS: A daily QA program was established to evaluate CT number accuracy and artifacts for both standard and ultra-high-resolution (UHR) scan modes. A complete system performance evaluation was conducted in accordance with the ACR CT QC manual by scanning the CT Accreditation Phantom with routine clinical protocols and reconstructing low-energy-threshold (T3D) and virtual monoenergetic images (VMIs) between 40 and 120 keV. Spatial resolution was evaluated by computing the modulation transfer function (MTF) for the UHR mode, and multi-energy performance was evaluated by scanning a body phantom containing four iodine inserts with concentrations between 2 and 15 mg I/cc. RESULTS: The daily QA program identified instances when the detector needed recalibration or replacement. CT number accuracy was impacted by image type: CT numbers at 70 keV VMI were within the acceptable range (defined for 120 kV). Other keV VMIs and the T3D reconstruction had at least one insert with CT number outside the acceptable range. The limiting resolution was nearly 40 lp/cm based on MTF measurements, which far exceeds the 12 lp/cm maximum capability of the ACR phantom. The CT numbers in the iodine inserts were accurate on all VMIs (3.8% average percentage error), while the iodine concentrations had an average root mean squared error of 0.3 mg I/cc. CONCLUSION: Protocols and parameters must be properly selected on PCD-CT to meet current accreditation requirements with the ACR CT phantom. Use of the 70 keV VMI allowed passing all tests prescribed in the ACR CT manual. Additional evaluations such an MTF measurement and multi-energy phantom scans are also recommended to comprehensively evaluate PCD-CT scanner performance.


Assuntos
Iodo , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas , Fótons , Protocolos Clínicos
8.
J Vasc Interv Radiol ; 34(1): 46-53.e4, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36202337

RESUMO

PURPOSE: To investigate the effect of simultaneous use of dual applicators on the image quality of real-time magnetic resonance (MR) thermometry and to characterize the dual-applicator treatment zone pattern during MR imaging-guided microwave ablation (MWA). MATERIALS AND METHODS: MWA experiments were performed on a 1.5-T MR scanner with 2 commercial microwave systems (902-928 MHz). Phantom experiments were first performed to evaluate the effect of dual-applicator MWA on the image quality of MR. Then, porcine tissue model experiments were conducted with real-time MR thermometry using either a single applicator or dual applicators inserted 2.6, 3.6, and 4.6 cm apart. Fiberoptic thermal probes were used to measure the temperature changes at the tissue surface. RESULTS: Simultaneous use of dual applicators resulted in a decrease in the relative signal-to-noise ratio (SNR) in the MR thermometry images to 55% ± 2.9% when compared with that of a single applicator (86.2% ± 2.0%). Despite the lower SNR, the temperature and ablation zone maps were of adequate quality to allow visualization of the ablation zone(s). The extents of increase in the temperature at the tissue surface using dual applicators (19.7 °C ± 2.6 °C) and a single applicator (18.2 °C ± 3.3 °C) were not significantly different (P = .40). Treatment zones were significantly larger (P < .05) in dual-applicator ablations (29.4 ± 0.4, 39.9 ± 0.6, and 42.6 ± 0.9 cm2 with 2.6-, 3.6-, and 4.6-cm spacing, respectively) at the end of the ablation procedure than in the single-applicator MWA (18.6 ± 0.9 cm2). CONCLUSIONS: MR imaging-guided dual-applicator MWA produced larger ablation zones while allowing adequate real-time MR thermometry image quality for monitoring the evolution of the treatment zone.


Assuntos
Micro-Ondas , Termometria , Suínos , Animais , Micro-Ondas/uso terapêutico , Fígado/patologia , Termometria/métodos , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética
9.
J Appl Clin Med Phys ; 23(12): e13812, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36321326

RESUMO

There is a lack of understanding in the performance of flexible noise control (FNC) processing, which is used in digital radiography on a scanner vendor and has four parameters each involving multiple options. The aim of this study was to investigate the impact of FNC on portable chest imaging. An anthropomorphic chest phantom was imaged using a clinical chest program with 85 kV and five radiation dose levels at 40″ source-to-image distance with software-based scatter reduction method. All images were processed without and with FNC. Noise analysis was performed in two regions of interest (ROI) on subtracted noise-only images, and line profiles were generated through a lung-rib interface. In addition, noise power spectra (NPS) analysis was performed in solid water phantoms of 10 and 20 cm thicknesses, using the same acquisition program and a range of dose levels. Last, feedback on retrospectively deidentified, reprocessed, and randomized clinical images from 20 portable chest exams was gathered from two thoracic radiologists. Noise reduction performances of FNC were demonstrated, with the level depending on specific FNC parameters, dose levels, ROI placement, and phantom sizes. Higher frequency textural patterns were revealed through the NPS analysis, which varied based on FNC parameters, dose levels, and phantom sizes. Overall, the vendor default parameter FGA0.5 yielded the highest noise reduction and textural artifacts. Radiologist feedback showed consistent preference of no FNC due to the presence of textural artifacts in the FNC-processed images. An algorithm improvement to avoid introducing artifacts would be desired.


Assuntos
Intensificação de Imagem Radiográfica , Radiografia Torácica , Humanos , Radiografia Torácica/métodos , Estudos Retrospectivos , Radiografia , Intensificação de Imagem Radiográfica/métodos , Pulmão/diagnóstico por imagem , Doses de Radiação , Imagens de Fantasmas
10.
J Med Imaging (Bellingham) ; 9(3): 035001, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35721310

RESUMO

Purpose: This work aims to develop a framework to accurately and efficiently simulate metallic objects used during interventional oncology (IO) procedures and their artifacts in computed tomography (CT) images of different body regions. Approach: A metal insertion framework based on an existing lesion insertion tool was developed. Noise and beam hardening models were incorporated into the model and validated by comparing images of real and artificially inserted metallic rods of known material composition and dimensions. The framework was further validated by inserting ablation probes into a water phantom and comparing image appearance to scans of real probes at matching locations in the phantom. Finally, a comprehensive library of metallic probes used in our IO practice was generated and a graphical user interface was built to efficiently insert any number of probes at arbitrary positions in patient CT data, including projection and image domain insertions. Results: Metallic rod experiments demonstrated that noise and beam hardening were properly modeled. Phantom and patient data with virtually inserted probes demonstrated similar artifact appearance and magnitude compared with real probes. The developed user interface resulted in accurately co-registered virtual probes both with and without accompanying artifacts from projection and image domain insertions, respectively. Conclusions: The developed metal insertion framework successfully replicates metallic object and artifact appearance with projection domain insertions and provides corresponding artifact-free images with the metallic object in the identical location through image domain insertion. This framework has potential to generate robust training libraries for deep learning algorithms and facilitate image quality optimization in interventional CT.

11.
Med Phys ; 49(3): 1458-1467, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35018658

RESUMO

PURPOSE: To demonstrate the feasibility of simultaneous dual-contrast imaging in a large animal using a newly developed dual-source energy-integrating detector (EID)-based multi-energy computed tomography (MECT) system. METHODS: Two imaging tasks that may have potential clinical applications were investigated: head/neck (HN) CT angiography (CTA)/CT venography (CTV) with iodine and gadolinium, and small bowel imaging with iodine and bismuth in domestic swine. Dual-source X-ray beam configurations of 70 kV + Au120/Sn120 kV and 70 kV + Au140/Sn140 kV were used for the HN-CTA/CTV and small bowel imaging studies, respectively. A test bolus scan was performed for each study. The regions of interest (ROIs) in the carotid artery and jugular vein for HN-CTA/CTV imaging and abdominal aorta for small bowel imaging were used to determine the time-attenuation curves, based on which the timing for contrast injection and the CT scan was determined. In the HN-CTA/CTV study, an MECT scan was performed at the time point corresponding to the optimal arterial enhancement by iodine and the optimal venous enhancement by gadolinium. In the small bowel imaging study, an MECT scan was performed at the optimal time point to simultaneously capture the mesenteric arterial enhancement of iodine and the enteric enhancement of bismuth. Image-based material decomposition was performed to decompose different materials for each study. To quantitatively characterize contrast material separation and misclassification, two ROIs on left common carotid artery and left internal jugular vein in HN-CTA/CTV imaging and three ROIs on superior mesenteric artery, ileal lumen, and collapsed ileum (ileal wall) in small bowel imaging were placed to measure the mean concentration values and the standard deviations. RESULTS: In the HN-CTA/CTV study, common carotid arteries containing iodine and internal/external jugular veins containing gadolinium were clearly delineated from each other. Fine vessels such as cephalic veins and branches of external jugular veins were noticeable but clear visualization was hindered by image noise in gadolinium-specific (CTV) images, as reviewed by a neuroradiologist. In the small bowel imaging study, the mesenteric arteries and collapsed bowel wall containing iodine and the small bowel loops containing bismuth were clearly distinctive from each other in the iodine- and bismuth-specific images after material decomposition, as reviewed by an abdominal radiologist. Quantitative analyses showed that the misclassifications between the two contrast materials were less than 1.7 and 0.1 mg/ml for CTA/CTV and small bowel imaging studies, respectively. CONCLUSIONS: Feasibility of simultaneous CTA/CTV imaging in head and neck with iodine and gadolinium and simultaneous imaging of arterial and enteric phases of small bowel with iodine and bismuth, using a dual-source EID-MECT system, was demonstrated in a swine study. Compared to iodine and gadolinium in CTA/CTV, better delineation and classification of iodine and bismuth in small bowel imaging were achieved mainly due to wider separation between the corresponding two K-edge energies.


Assuntos
Meios de Contraste , Iodo , Animais , Estudos de Viabilidade , Imagens de Fantasmas , Suínos , Tomografia Computadorizada por Raios X/métodos
12.
Invest Radiol ; 57(2): 122-129, 2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-34411033

RESUMO

PURPOSE: The aims of this study were to develop a single-scan dual-contrast protocol for biphasic liver imaging with 2 intravenous contrast agents (iodine and gadolinium) and to evaluate its effectiveness in an exploratory swine study using a photon-counting detector computed tomography (PCD-CT) system. MATERIALS AND METHODS: A dual-contrast CT protocol was developed for PCD-CT to simultaneously acquire 2 phases of liver contrast enhancement, with the late arterial phase enhanced by 1 contrast agent (iodine-based) and the portal venous phase enhanced by the other (gadolinium-based). A gadolinium contrast bolus (gadobutrol: 64 mL, 8 mL/s) and an iodine contrast bolus (iohexol: 40 mL, 5 mL/s) were intravenously injected in the femoral vein of a healthy domestic swine, with the second injection initiated after 17 seconds from the beginning of the first injection; PCD-CT image acquisition was performed 12 seconds after the beginning of the iodine contrast injection. A convolutional neural network (CNN)-based denoising technique was applied to PCD-CT images to overcome the inherent noise magnification issue in iodine/gadolinium decomposition task. Iodine and gadolinium material maps were generated using a 3-material decomposition method in image space. A set of contrast samples (mixed iodine and gadolinium) was attached to the swine belly; quantitative accuracy of material decomposition in these inserts between measured and true concentrations was calculated using root mean square error. An abdominal radiologist qualitatively evaluated the delineation of arterial and venous vasculatures in the swine liver using iodine and gadolinium maps obtained using the dual-contrast PCD-CT protocol. RESULTS: The iodine and gadolinium samples attached to the swine were quantified with root mean square error values of 0.75 mg/mL for iodine and 0.45 mg/mL for gadolinium from the contrast material maps derived from the denoised PCD-CT images. Hepatic arteries containing iodine and veins containing gadolinium in the swine liver could be clearly visualized. Compared with the original images, better distinctions between 2 liver phases were achieved using CNN denoising, with approximately 60% to 80% noise reduction in contrast material maps acquired with the denoised PCD-CT images compared with the original images. CONCLUSIONS: Simultaneous biphasic liver imaging in a single multienergy PCD-CT acquisition using a dual-contrast (iodine and gadolinium) injection protocol and CNN denoising was demonstrated in a swine study, where the enhanced hepatic arteries (containing iodine) and the enhanced hepatic veins (containing gadolinium) could be clearly visualized and delineated in the swine liver.


Assuntos
Gadolínio , Iodo , Animais , Meios de Contraste , Fígado/diagnóstico por imagem , Imagens de Fantasmas , Fótons , Suínos , Tomografia Computadorizada por Raios X/métodos
13.
Med Phys ; 48(10): 5712-5726, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34415068

RESUMO

OBJECTIVE: In X-raycomputed tomography (CT), many important clinical applications may benefit from a fast acquisition speed. The helical scan is the most widely used acquisition mode in clinical CT, where a fast helical pitch can improve the acquisition speed. However, on a typical single-source helical CT (SSCT) system, the helical pitch p typically cannot exceed 1.5; otherwise, reconstruction artifacts will result from data insufficiency. The purpose of this work is to develop a deep convolutional neural network (CNN) to correct for artifacts caused by an ultra-fast pitch, which can enable faster acquisition speed than what is currently achievable. METHODS: A customized CNN (denoted as ultra-fast-pitch network (UFP-net)) was developed to restore the underlying anatomical structure from the artifact-corrupted post-reconstruction data acquired from SSCT with ultra-fast pitch (i.e., p ≥ 2). UFP-net employed residual learning to capture the features of image artifacts. UFP-net further deployed in-house-customized functional blocks with spatial-domain local operators and frequency-domain non-local operators, to explore multi-scale feature representation. Images of contrast-enhanced patient exams (n = 83) with routine pitch setting (i.e., p < 1) were retrospectively collected, which were used as training and testing datasets. This patient cohort involved CT exams over different scan ranges of anatomy (chest, abdomen, and pelvis) and CT systems (Siemens Definition, Definition Flash, Definition AS+, Siemens Healthcare, Inc.), and the corresponding base CT scanning protocols used consistent settings of major scan parameters (e.g., collimation and pitch). Forward projection of the original images was calculated to synthesize helical CT scans with one regular pitch setting (p = 1) and two ultra-fast-pitch setting (p = 2 and 3). All patient images were reconstructed using the standard filtered-back-projection (FBP) algorithm. A customized multi-stage training scheme was developed to incrementally optimize the parameters of UFP-net, using ultra-fast-pitch images as network inputs and regular pitch images as labels. Visual inspection was conducted to evaluate image quality. Structural similarity index (SSIM) and relative root-mean-square error (rRMSE) were used as quantitative quality metrics. RESULTS: The UFP-net dramatically improved image quality over standard FBP at both ultra-fast-pitch settings. At p = 2, UFP-net yielded higher mean SSIM (> 0.98) with lower mean rRMSE (< 2.9%), compared to FBP (mean SSIM < 0.93; mean rRMSE > 9.1%). Quantitative metrics at p = 3: UFP-net-mean SSIM [0.86, 0.94] and mean rRMSE [5.0%, 8.2%]; FBP-mean SSIM [0.36, 0.61] and mean rRMSE [36.0%, 58.6%]. CONCLUSION: The proposed UFP-net has the potential to enable ultra-fast data acquisition in clinical CT without sacrificing image quality. This method has demonstrated reasonable generalizability over different body parts when the corresponding CT exams involved consistent base scan parameters.


Assuntos
Aprendizado Profundo , Artefatos , Humanos , Processamento de Imagem Assistida por Computador , Redes Neurais de Computação , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
14.
J Comput Assist Tomogr ; 45(5): 691-695, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34407061

RESUMO

OBJECTIVE: The aim of this study was to compare the contrast enhancement differences between gadolinium-based and iodine-based contrast agents at different single-energy tube potentials and dual-energy-based virtual monochromatic energies. In addition, we describe the application of a gadolinium-based contrast agent in computed tomography (CT) cystography for a patient with contraindications to iodine. METHODS: A phantom study was performed using 3 iodine samples (concentrations: 5, 10, and 15 mgI/mL) and 3 gadolinium samples (concentrations: 3.3, 6.6, and 9.9 mgGd/mL). The prepared phantom was scanned by a dual-energy CT (DECT) at 80, 100, 120, and 140 kV in the single-energy mode and at 100/Sn140 kV in the dual-energy mode. Virtual monoenergetic images (VMIs) at 50 keV were generated from the DECT scan. In addition, a DECT cystogram was performed using a gadolinium-based contrast agent in a patient with contraindications to iodinated contrast. RESULTS: Strong linear correlations between mean signal of contrast enhancement and mass concentration were found for both iodine and gadolinium samples across all single-energy CT (SECT) and DECT scan conditions. The VMI at 50 keV provided the highest contrast enhancement for both types of contrast samples at each concentration level, and single-energy CT scans at low-energy beams showed higher contrast enhancement than higher beam energies. In addition, the contrast enhancement for pure gadolinium solution was constantly higher than pure iodine solution at an identical mass concentration level. The DECT cystogram was performed with excellent technical success. The urinary bladder was appropriately distended with intravesical contrast measuring 606 Hounsfield units and no evidence of bladder leak or fistula. CONCLUSIONS: Imaging of gadolinium-based contrast agents is improved using a DECT technique, with VMI at 50 keV providing the highest contrast enhancement among our tested parameters. Dual-energy CT cystography using a gadolinium-based agent can be a safe and effective alternative when iodinated agents are contraindicated.


Assuntos
Meios de Contraste , Cistografia/métodos , Compostos Organometálicos , Intensificação de Imagem Radiográfica/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Doenças da Bexiga Urinária/diagnóstico por imagem , Estudos de Viabilidade , Feminino , Gadolínio , Humanos , Iodo , Pessoa de Meia-Idade , Imagens de Fantasmas , Bexiga Urinária/diagnóstico por imagem
15.
Artigo em Inglês | MEDLINE | ID: mdl-33986559

RESUMO

Channelized Hotelling observer (CHO), which has been shown to be well correlated with human observer performance in many clinical CT tasks, has a great potential to become the method of choice for objective image quality assessment. However, the use of CHO in clinical CT is still quite limited, mainly due to its complexity in measurement and calculation in practice, and the lack of access to an efficient and validated software tool for most clinical users. In this work, a web-based software platform for CT image quality assessment and protocol optimization (CTPro) was introduced. A validated CHO tool, along with other common image quality assessment tools, was made readily accessible through this web platform for clinical users and researchers without the need of installing additional software. An example of its application to evaluation of convolutional-neural-network (CNN)-based denoising was demonstrated.

16.
Med Phys ; 48(9): 4857-4871, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33988849

RESUMO

PURPOSE: Multi-energy computed tomography (MECT) has a great potential to enable many novel clinical applications such as simultaneous multi-contrast imaging. The purpose of this study was to implement triple-beam MECT on a traditional energy-integrating-detector (EID) CT platform (EID-MECT). METHODS: This was accomplished by mounting a z-axis split-filter (0.05 mm Au, 0.6 mm Sn) on Tube A of a dual-source EID CT scanner. With the two split x-ray beams from Tube A and the third beam from Tube B, three beams with different x-ray spectra can be simultaneously acquired. With Tube B operated at 70 or 80 kV and Tube A at 120 or 140 kV, four different triple-beam configurations were calibrated for MECT measurements: 70/Au120/Sn120, 80/Au120/Sn120, 70/Au140/Sn140, and 80/Au140/Sn140 kV. Iodine (I), gadolinium (Gd), bismuth (Bi) samples, and their mixtures were prepared for 2 three-material-decomposition tasks and 1 four-material-decomposition task. For each task, samples were placed in a water phantom and scanned using each of the four triple-beam configurations. For comparison, the same phantom was also scanned using three other dual-energy CT (DECT) or MECT technologies: twin-beam DECT (TB-DECT), dual-source DECT (DS-DECT), and photon-counting-detector CT (PCD-CT), all with optimal x-ray spectrum settings and at equal volume CT dose index (CTDIvol). The phantom for four-material decomposition (I/Gd/Bi/Water imaging) was scanned using the PCD-CT only (140 kV with 25, 50, 75, and 90 keV). Image-based material decomposition was performed to acquire material-specific images, on which the mean basis material concentrations and noise levels were measured and compared across all triple-beam configurations in EID-MECT and various DECT/MECT systems. RESULTS: The optimal triple-beam configuration was task-dependent with 70/Au120/Sn120, 70/Au140/Sn140, and 70/Au120/Sn120 kV for I/Gd/Water, I/Bi/Water, and I/Gd/Bi/Water material decomposition tasks, respectively. At equal radiation dose level, EID-MECT provided comparable or better quantification accuracy in material-specific images for all three material decomposition tasks, compared to EID-based DECT and PCD-CT systems. In terms of noise level comparison, EID-MECT-derived material-specific images showed lower noise levels than TB-DECT and DS-DECT, but slightly higher than that from PCD-CT in I/Gd/Water imaging. For I/Bi/Water imaging, EID-MECT showed a comparable noise level to DS-DECT, and a much lower noise level than TB-DECT and PCD-CT in all material-specific images. For the four-material decomposition task involving I/Gd/Bi/Water, the bismuth-specific image derived from EID-MECT was slightly noisier, but both iodine- and gadolinium-specific images showed much lower noise levels in comparison to PCD-CT. CONCLUSIONS: For the first time, an EID-based MECT system that can simultaneously acquire three x-ray spectra measurements was implemented on a clinical scanner, which demonstrated comparable or better imaging performance than existing DECT and MECT systems.


Assuntos
Iodo , Fótons , Imagens de Fantasmas , Doses de Radiação , Tomografia Computadorizada por Raios X
17.
Invest Radiol ; 55(10): 688-694, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32530868

RESUMO

OBJECTIVES: Dual-energy and multienergy computed tomography (DECT/MECT) has the potential to simultaneously visualize two contrast agents in the small bowel: arterial enhancement of iodine in the bowel wall and enteric enhancement of bismuth in the bowel lumen. The purpose of this study was to explore its feasibility in a swine study using a research whole-body photon-counting-detector (PCD) computed tomography (CT) system. MATERIALS AND METHODS: A phantom study was initially performed to evaluate the quantification accuracy of iodine and bismuth separation from a single PCD-CT scan, which also served as the calibration reference for material decomposition of in vivo swine PCD-CT data. In the animal study, a test bolus scan was first performed to determine the time-attenuation curve for the arterial enhancement, based on which the timing of the PCD-CT dual-contrast scan was determined. A 600 mL homogeneous bismuth-saline solution (180 mL Pepto-Bismol + 420 mL normal saline) was orally administered to the pig using esophageal intubation. Approximately 1 hour after bismuth administration, 40 mL iodine contrast (Omnipaque 350, 5 mL/s) was injected intravenously. A PCD-CT scan was performed 13 seconds after the initiation of the contrast injection to simultaneously capture the arterial enhancement of iodine and the enteric enhancement of bismuth. To provide optimal material separation and quantification, all PCD-CT scans in both phantom and animal studies were operated at 140 kV with 4 energy thresholds of 25, 50, 75, and 90 keV. RESULTS: Using a generic image-based material decomposition method, the iodine and bismuth samples were successfully delineated and quantified in the phantom images with a root-mean-square-error of 1.32 mg/mL in iodine measurement and 0.64 mg/mL in bismuth measurement. In the pig study, the enhancing bowel wall containing iodine and the small bowel loop containing bismuth were not differentiable in the original PCD-CT images. However, they were clearly distinctive from each other in the iodine- and bismuth-specific images after material decomposition, as reviewed by an abdominal radiologist. In addition, quantitative analysis showed that the misclassification between the two contrast materials was less than 1.0 mg/mL. CONCLUSIONS: Our study demonstrated the feasibility of simultaneous imaging of iodine and bismuth in small bowel of swine using PCD-CT.


Assuntos
Bismuto , Intestino Delgado/diagnóstico por imagem , Iodo , Fótons , Tomografia Computadorizada por Raios X/métodos , Animais , Meios de Contraste , Estudos de Viabilidade , Humanos , Imagens de Fantasmas , Suínos
18.
J Biomech Eng ; 142(3)2020 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-32006021

RESUMO

Density and mechanical properties (e.g., compressibility or bulk modulus) are important cellular biophysical markers. As such, developing a method to separate cells directly based on these properties can benefit various applications including biological research, diagnosis, prognosis, and therapeutics. As a potential solution, surface acoustic wave (SAW)-based cell separation has demonstrated advantages in terms of biocompatibility and compact device size. However, most SAW-reliant cell separations are achieved using an entangled effect of density, various mechanical properties, and size. In this work, we demonstrate SAW-based separation of cells/particles based on their density and compressibility, irrespective of their sizes, by manipulating the acoustic properties of the fluidic medium. Using our platform, SAW-based separation is achieved by varying the dimensions of the microfluidic channels, the wavelengths of acoustic signals, and the properties of the fluid media. Our method was applied to separate paraformaldehyde-treated and fresh Hela cells based on differences in mechanical properties; a recovery rate of 85% for fixed cells was achieved. It was also applied to separate red blood cells (RBCs) and white blood cells (WBCs) which have different densities. A recovery rate of 80.5% for WBCs was achieved.


Assuntos
Acústica , Separação Celular , Eritrócitos , Células HeLa , Humanos
19.
Artigo em Inglês | MEDLINE | ID: mdl-35414740

RESUMO

Energy-integrating-detector (EID)-based triple-beam multi-energy CT (TB-MECT) was recently implemented on a dual-source (DS) CT platform by mounting a z-axis split-filter (0.05 mm Au, 0.6 mm Sn) on one of the two tubes. The purpose of this work is to perform a feasibility animal study on this new MECT platform for a small bowel imaging task using two contrast agents, iodine and bismuth. Optimal triple-beam configurations, 70/Au140/Sn140 kV were determined in a phantom study for this task and applied in the animal study for best material decomposition imaging performance. The results demonstrated that the TB-MECT can successfully separate and quantify the two contrast agents from one single scan for the task of small bowel imaging.

20.
Med Phys ; 47(2): 441-456, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31705664

RESUMO

PURPOSE: To evaluate the quantitative accuracy and dose efficiency of simultaneous imaging of two contrast agents using dual-energy computed tomography (DECT), two imaging tasks each representing one potential clinical application were investigated in a phantom study: biphasic liver imaging with iodine and gadolinium, and small bowel imaging with iodine and bismuth. METHODS: To separate and quantify mixtures of two contrast agents using a single DECT scan, mixed iodine and gadolinium samples were prepared with the contrast enhancement values corresponding to the late arterial (iodine) and the portal-venous (gadolinium) phase for biphasic liver imaging. Mixed iodine and bismuth samples were prepared mimicking the arterial (iodine) and the enteric (bismuth) enhancement for small bowel imaging. For comparison to the reference condition of performing two single-energy CT (SECT) scans, contrast samples were prepared separately to mimic separate scans in the arterial/venous phase and arterial/enteric enhancement. Samples were placed in a 35 cm wide water tank and scanned using a third-generation dual-source DECT scanner with three tube potential pairs: 80/Sn150, 90/Sn150, and 100/Sn150 kV, all with default dose partitioning between two x-ray beams to acquire DECT data. The same scanner operated in a single-energy mode acquired SECT data (120 kV). Total radiation dose (CTDIvol) was matched for the single-scan DECT and the two-scan SECT protocols. The DECT protocol was followed by a generic image-based three-material decomposition method to determine the material-specific images, based on which concentrations of each basis material were quantified and noise levels were measured. To compare with the SECT images directly acquired with the SECT protocol, the concentration values in each contrast-specific image were converted to CT numbers at 120 kV (i.e., virtual SECT (vSECT) images). The noise level and noise power spectra differences between the SECT and vSECT images were compared to evaluate the dose efficiency of the single-scan DECT protocol. The impact of dose partitioning in the DECT protocol on quantitative dual-contrast imaging performance was also studied. RESULTS: For each imaging task, contrast materials were accurately quantified against the nominal concentrations using the DECT data with strong correlation (R2  ≥ 0.98 for both imaging tasks). Compared to the SECT protocol, the DECT protocol was not dose efficient. With the optimal x-ray tube potential pair 80/Sn150 kV, the noise level in vSECT images increased by 401%/488% (arterial/portal-venous) for the biphasic liver imaging task and by 10%/41% (arterial/enteric) for the small bowel imaging task compared to that in SECT images. The corresponding radiation dose increase is 2410%/3357% for the biphasic liver imaging task and 21%/99% for the small bowel imaging task, respectively, to achieve the same noise as that in SECT images. This could be improved by adjusting the dose partitioning in DECT. CONCLUSIONS: DECT can be used to simultaneously separate and quantify two contrast materials. However, compared to a two-scan SECT protocol, much higher radiation dose is needed in a single-scan DECT protocol to achieve the same image noise, especially for tasks involving the dual contrast of iodine and gadolinium.


Assuntos
Imagens de Fantasmas , Doses de Radiação , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X/instrumentação , Meios de Contraste , Humanos , Intestino Delgado/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...