Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Heliyon ; 10(4): e26364, 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38420384

RESUMO

The key solution to combat trace metal pollution and keep the environment, ecosystem, animals, and humans safe is earlier and rapid trace metal detection. For all these reasons, we propose in this work the design of a simple electrochemical sensor functionalized with green nanoparticles for electrochemical detection of the fourth most dangerous heavy metal ions namely copper, zinc, lead, and mercury. The green nanoparticles are fabricated by a one-step, consisting of reducing platinum nanoparticles by a natural gum Arabic polymer. To guarantee the success of these nanoparticles' design, the nanoparticles have been characterized by Fourier-transform infrared spectroscopy FTIR, and thermogravimetric TGA techniques. While, for the electrochemical characterization, we have adopted cyclic voltammetry CV and electrochemical impedance spectroscopy EIS to control different steps of surface modification, and the differential pulse anodic stripping DPAS was monitored to follow up the electrochemical detection of different heavy metals. Results: have confirmed the good chemical and physical properties of the elaborated nanoparticles. As, the developed sensor showed a specific electrochemical response toward the heavy metal ions separately, with a lower limit of detection lower LOD than that recommended by the World Health Organization, in order of 9.6 ppb for Cu2+, 1.9 ppb for Zn2+, 0.9 ppb for Hg2+, and 4.2 ppb for Pb2+. Impressively, the elaborated sensor has demonstrated also high stability, outstanding sensitivity, and excellent analytical performance.In addition, the elaborated analytical tool has been successfully applied to the determination of various heavy metal ions in real samples, reflecting then its promising prospect in practical application.

2.
Artigo em Inglês | MEDLINE | ID: mdl-18001902

RESUMO

There is an unmet medical need for a more reliable and earlier assessment of patients suspected of having a deep vein thrombosis. We describe a novel approach which is developing a highly reliable, accurate, portable and handheld prototype medical diagnostic device to improve radically the speed, accuracy and reliability with which DVT and related blood clotting conditions can be assessed. The device will measure whole blood concentration of D-dimer, a recognized biomarker of increased blood clotting activity, and through innovation in the development of a novel detection, measurement and reporting system, will offer the opportunity to use the test in the point of care setting. The device combines innovation in antibody bio-engineering for high specificity immunoassay-based diagnostics and nano/micro engineered impedimetric analysis electrodes incorporating a biocompatible polymer substrate with development of a disposable microfluidic manifold specifically enabling diagnostics at the point-of-first-contact.


Assuntos
Produtos de Degradação da Fibrina e do Fibrinogênio/análise , Imunoensaio/métodos , Trombose Venosa/sangue , Especificidade de Anticorpos , Materiais Biocompatíveis/química , Biomarcadores/sangue , Impedância Elétrica , Humanos , Imunoensaio/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Sistemas Automatizados de Assistência Junto ao Leito , Polímeros/química , Trombose Venosa/diagnóstico
3.
Talanta ; 69(2): 450-5, 2006 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-18970588

RESUMO

A highly sensitive, fast and stable conductometric enzyme biosensor for determination of nitrate in water is reported for the first time. The biosensor electrodes were modified by methyl viologen mediator mixed with nitrate reductase (NR) from Aspergillus niger by cross-linking with glutaraldehyde in the presence of bovine serum albumin and Nafion((R)) cation-exchange polymer. The process parameters for the fabrication of the enzyme electrode and various experimental variables such as pH, the enzyme loading and time of immobilization in glutaralaldehyde vapor were investigated with regard to their influence on sensitivity, limit of detection, dynamic range and operational and storage stability. The biosensor can reach 95% of steady-state conductance value in about 15s. Linear calibration in the range of 0.02 and 0.25 mM with detection limits of 0.005 mM nitrate was obtained with a signal-to-noise ratio of 3. When stored in 5 mM phosphate buffer (pH 7.5) at 4 degrees C, the sensor showed good stability over 2 weeks.

4.
Talanta ; 63(2): 365-70, 2004 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-18969441

RESUMO

The determination of diuron, atrazine, desisopropylatrazine (DIA) and desethylatrazine (DEA) were investigated using conductometric tyrosinase biosensor. Tyrosinase was immobilised on the biosensor sensitive part by allowing it to mix with bovine serum albumin (BSA) and then cross-linking in saturated glutaraldehyde (GA) vapour for 30min. The determination of pollutants in a solution was performed by comparison of the output signal (i.e percentage of the enzymatic activity) of the biosensor before and after contact with pollutants. The measurement of the enzymatic activity was performed using 4-chlorophenol, phenol and catechol substrates and response times ranging from 1 to 5min were observed. A 4-chlorophenol substrate was used to detect pesticides. A 30min contact time of the biosensor in the pollutant solution was used. Under the experimental conditions employed, detection limits for diuron and atrazine were about 1ppb and dynamic range of 2.3-2330 and 2.15-2150ppb were obtained for diuron and atrazine, respectively. A relative standard deviation (n=3) of the output signal was estimated to be 5% and a slight drift of 1.5muSh(-1) was observed. The 90% of the enzyme activity was still maintained after 23 days of storage in a buffer solution at 4 degrees C.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...