Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Med Tekh ; (6): 3-10, 2001.
Artigo em Russo | MEDLINE | ID: mdl-11837192

RESUMO

Treatment of extensive tissue defects should be complex, whose basis is an early free skin plastic repair with obligatory addition of agents that enhance the reparative capacities of tissues. For this, the authors propose a number of original appliances (forceps, variants of dermoperforators, bandage, etc.) and drugs, such as ximedon (tablets, 5-10% aqueous solution, lanolin-vaseline-based ointment, talc-based powder), whose clinical trials in 300 patients have shown their high therapeutical effect. The time of preparation of the wound surface for dermatoplastic interventions became shorter and the frequency of poor outcomes of operations reduced.


Assuntos
Adjuvantes Imunológicos/uso terapêutico , Pirimidinas/uso terapêutico , Transplante de Pele/instrumentação , Transplante de Pele/métodos , Adjuvantes Imunológicos/administração & dosagem , Humanos , Pomadas , Pirimidinas/administração & dosagem , Regeneração , Fenômenos Fisiológicos da Pele , Lesões dos Tecidos Moles/cirurgia , Retalhos Cirúrgicos , Instrumentos Cirúrgicos
3.
Khirurgiia (Mosk) ; (6): 75-8, 1989 Jun.
Artigo em Russo | MEDLINE | ID: mdl-2779131

RESUMO

Experiments on 200 animals and clinical use of 300 scalpels differing in the width of the cutting edge showed that operative lineal skin incisions made with a sharp instrument (a ruby knife, razor, scalpel with a 0.8 microns cutting edge) heal better and quicker than those inflicted with a blunt scalpel of serial production with a cutting edge 12.5 microns wide. Such blunting of scapels occurs after two operations and traditional methods of sterilization of the instruments. Mechanical damage of the instruments during cleansing and washing is most important in the clinic.


Assuntos
Ligas , Procedimentos Cirúrgicos Dermatológicos , Aço , Instrumentos Cirúrgicos/normas , Cicatrização , Ferimentos Penetrantes/fisiopatologia , Animais , Humanos , Coelhos , Ratos , Pele/fisiopatologia , Ferimentos Penetrantes/etiologia
4.
Med Tekh ; (2): 10-3, 1988.
Artigo em Russo | MEDLINE | ID: mdl-3405054

RESUMO

Tiny rotation-plate pneumomotors be made with a rotor lengthened to 3-5 diametres of a rotor with simultaneous gaz supply through 2-3 channels. It is recommended to use the kinetic energy of air current and a piston system of pneumomotor start.


Assuntos
Desenho de Equipamento , Equipamentos Ortopédicos/normas , Osteotomia/instrumentação , Ar , Humanos , Pressão , Rotação , Suíça , U.R.S.S.
5.
Med Tekh ; (2): 3-10, 1988.
Artigo em Russo | MEDLINE | ID: mdl-3405061

RESUMO

New original constructions of pneumatic motors and nozzles (with guaranteed start up of a pneumomotor with a nozzle) are described. They ensure non-traumatic treatment of osseous tissues and exclude the breakage of a cutting instrument in work.


Assuntos
Doenças Ósseas/cirurgia , Fraturas Ósseas/cirurgia , Equipamentos Ortopédicos , Osteotomia/instrumentação , Ar , Desenho de Equipamento , Europa (Continente) , Humanos , Pressão , U.R.S.S. , Estados Unidos
6.
Med Tekh ; (1): 36-40, 1988.
Artigo em Russo | MEDLINE | ID: mdl-3362053

RESUMO

Introduction of newer dental instruments is foreseen owing to the perfection of manufacturing methods, equipment and rigging.


Assuntos
Equipamentos Odontológicos , Instrumentos Odontológicos , Humanos , U.R.S.S.
7.
Med Tekh ; (1): 7-11, 1988.
Artigo em Russo | MEDLINE | ID: mdl-3362058

RESUMO

Piston compressor without lubrication with air blow to packing rings by plunger, disposed in subpiston space, is recommended as the basic scheme of construction of a power supply unit for medical pneumatic tooling. The construction reduces a leak of the compressive medium, increasing the efficiency of a compressor and seal reliability.


Assuntos
Fontes de Energia Elétrica , Ciência de Laboratório Médico/instrumentação , Lubrificação
8.
Med Tekh ; (1): 43-8, 1987.
Artigo em Russo | MEDLINE | ID: mdl-3550360

RESUMO

The main tendency in designing mechanized medical instruments is developing systems with automatic fine adjustment and self-regulation. The automated gear adjustment, self-regulating mouthpieces and cutting tools create a flexible automated system with optimal cutting regime. The instruments do not overheat bone tissues which helps to avoid unnecessary traumatization.


Assuntos
Osso e Ossos/cirurgia , Equipamentos Cirúrgicos , Instrumentos Cirúrgicos , Fontes de Energia Elétrica , Desenho de Equipamento , Humanos , Movimento (Física) , Transdutores
10.
Med Tekh ; (2): 50-1, 1984.
Artigo em Russo | MEDLINE | ID: mdl-6374362

RESUMO

A set for experimental studies of heat release in the process of bone cutting by drills , circular saws, cutters and so on is produced and tested. With the set, a rotational speed of instruments may be varied over a range of I to 200 s-1 and up to 8330 s-1 when using dental tips.


Assuntos
Equipamentos Odontológicos de Alta Rotação , Osteotomia/instrumentação , Trepanação/instrumentação , Humanos , Rotação
11.
Med Tekh ; (1): 41-5, 1984.
Artigo em Russo | MEDLINE | ID: mdl-6708765

RESUMO

An experimental set is developed to study and test pneumatic micromotors. With the set, the following parameters may be measured: a rotatory speed, a torque, air discharge and pressure, temperature of the micromotor housing. The set may be also used as a load in tests for reability.


Assuntos
Eletrônica Médica/instrumentação , Equipamentos e Provisões , Desenho de Equipamento , Estudos de Avaliação como Assunto
12.
Med Tekh ; (1): 26-31, 1984.
Artigo em Russo | MEDLINE | ID: mdl-6369063

RESUMO

The method to compute friction loss in medical microturbines and tips at the stage of their development is proposed. It is verified when designing friction loss of the following devices: a turbine tip HTC-300-02, a pneumatic micromotor MMP-20, and micromotor tips (NVP-30M) and (NP-30M). The method may be useful in estimated designs of friction loss.


Assuntos
Equipamentos Odontológicos de Alta Rotação , Desenho de Equipamento , Falha de Equipamento , Matemática , Estresse Mecânico
13.
Med Tekh ; (6): 16-9, 1983.
Artigo em Russo | MEDLINE | ID: mdl-6664262

RESUMO

Rotary-plate motors with the increased power are recommended for using in medical pneumatically-driven instruments. Provided in the design bumper pockets make it possible to raise the power of the pneumatic motor while its dimensions and weight remain unchanged.


Assuntos
Equipamentos e Provisões , Desenho de Equipamento , Ciência de Laboratório Médico
14.
Med Tekh ; (3): 5-9, 1983.
Artigo em Russo | MEDLINE | ID: mdl-6888225

RESUMO

The methodology of designing performance for medical microturbines is described. The method has been verified when designing the net moment and power of a turbine tip HTC-300-02 and a micromotor MMp-20. The comparison of theoretical and experimental data has shown the discordance to be less than 5%.


Assuntos
Equipamentos e Provisões , Desenho de Equipamento , Matemática , Rotação
15.
Med Tekh ; (2): 14-9, 1983.
Artigo em Russo | MEDLINE | ID: mdl-6343753

RESUMO

In order to extend an operating range of angular tips, six types of these tips for micromotors and a coupling are designed. In the course of experimental studies using a suitable set the temperature of heads as well as friction loss in the tips and the coupling have been measured. The specified relationships made it possible to define more exactly the operating range for the tips according to their rotational speed.


Assuntos
Equipamentos Odontológicos de Alta Rotação , Tecnologia Odontológica
16.
Med Tekh ; (3): 21-4, 1982.
Artigo em Russo | MEDLINE | ID: mdl-7050601

RESUMO

Experimental studies of handpieces for micromotors have been performed to make more precise their operating parameters. The special stand has been used for the measurements of the following data: head temperature, power losses in handpieces at no-load, and operating power required for machining by means of spherical burrs. The experimental results made it possible to specify more exactly the range of handpiece rotational speeds and to select optimum loads under reliability testing.


Assuntos
Equipamentos Odontológicos de Alta Rotação , Estudos de Avaliação como Assunto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...