Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Vasc Surg ; 2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38462062

RESUMO

OBJECTIVE: Management of follow-up protocols after endovascular aortic repair (EVAR) varies significantly between centers and is not standardized according to sac regression. By designing an international expert-based Delphi consensus, the study aimed to create recommendations on follow-up after EVAR according to sac evolution. METHODS: Eight facilitators created appropriate statements regarding the study topic that were voted, using a 4-point Likert scale, by a selected panel of international experts using a three-round modified Delphi consensus process. Based on the experts' responses, only those statements reaching a grade A (full agreement ≥75%) or B (overall agreement ≥80% and full disagreement <5%) were included in the final document. RESULTS: One-hundred and seventy-four participants were included in the final analysis, and each voted the initial 29 statements related to the definition of sac regression (Q1-Q9), EVAR follow-up (Q10-Q14), and the assessment and role of sac regression during follow-up (Q15-Q29). At the end of the process, 2 statements (6.9%) were rejected, 9 statements (31%) received a grade B consensus strength, and 18 (62.1%) reached a grade A consensus strength. Of 27 final statements, 15 (55.6%) were classified as grade I, whereas 12 (44.4%) were classified as grade II. Experts agreed that sac regression should be considered an important indicator of EVAR success and always be assessed during follow-up after EVAR. CONCLUSIONS: Based on the elevated strength and high consistency of this international expert-based Delphi consensus, most of the statements might guide the current clinical management of follow-up after EVAR according to the sac regression. Future studies are needed to clarify debated issues.

2.
Abdom Radiol (NY) ; 49(1): 312-319, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37978076

RESUMO

PURPOSE: To evaluate the diagnostic capabilities of a supplementary color ramped iodine density map compared to virtual monoenergetic images (VMIs) at 74 keV in the diagnosis of acute bowel ischemia (ABI). METHODS: Data for this study were prospectively gathered and retrospectively evaluated. Patients referred to the Department of Diagnostic Radiology between October 2020 and August 2022 on the suspicion of ABI and underwent surgery < 12 h following fast kV-switching venous phase abdominal dual-energy CT (DECT) were consecutively included. Images were evaluated by two board-certified radiologists and two radiology residents. First round included only 74 keV VMIs resembling conventional 120 kVp images, and the second round included a supplementary iodine density map. Readers were asked to register presence of ABI as well as their confidence in their diagnosis based on a 5-point Likert scale. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated for each observer with the surgical findings as the gold-standard. McNemar's and Wilcoxon signed-rank test were used to compare registrations and diagnostic confidence across assessment rounds. RESULTS: A total of 29 patients resulting in 31 DECT scans were included. Fourteen cases of ischemic/necrotic bowel were reported following surgery. Sensitivity and NPV were decreased with the use of supplementary iodine map images compared to 120 kVp-like images without supplementary iodine map images for three of four observers (round 1 range: 71.4-92.9% and 78.0-94.8%; round 2 range: 57.1-78.6% and 70.1-83.3%, respectively), while specificity and PPV were increased for three of four observers (round 1 range: 64.7-94.1% and 67.4-93.1%; round 2 range: 88.2-94.1% and 73.8-91.1%, respectively). However, no significant difference in ABI diagnosis or diagnostic confidence was found (p-value range: 0.07-1.00 and 0.23-0.58, respectively). CONCLUSION: No significant difference for the diagnosis of ABI was found using supplementary iodine mapping. Our study may suggest a trend of increased specificity and decreased sensitivity, hence, the use of supplementary iodine mapping should be carefully considered.


Assuntos
Iodo , Isquemia Mesentérica , Humanos , Tomografia Computadorizada por Raios X/métodos , Estudos Retrospectivos , Valor Preditivo dos Testes , Isquemia , Meios de Contraste
3.
J Vasc Surg ; 79(2): 198-206.e15, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37967588

RESUMO

OBJECTIVE: We assessed the suitability of two triple branch arch devices (aBranch) (Terumo aortic and Cook Medical) and a balloon-expandable covered stent (VBX, W. L. Gore & Associates, Johnson & Johnson) to incorporate the brachiocephalic trunk (BCT) in a cohort previously treated with hybrid thoracic endovascular repair (TEVAR). METHODS: This is a single-center, retrospective, all-comers, preclinical suitability study. We conducted an analysis of preoperative computed tomography scans in surgical patients between 1999 and 2022 in a single vascular surgery unit. The primary outcome was the aortic suitability of aBranch devices and VBX as mating stent for BCT in previous hybrid TEVAR. Hybrid repair of the aortic arch included TEVAR, fenestrated or branched TEVAR associated with any surgical debranching of the supra-aortic trunks and chimney TEVAR with proximal landing in zones 0 to 2. Secondary outcomes included (i) suitability assessment when excluding minor instruction for use (IFU) criteria, (ii) a comparison of suitable and nonsuitable patients, (iii) risk factors analysis for nonsuitability, and (iv) a description of the exclusion causes. RESULTS: During the study period, 120 patients were treated. Among elective patients (n = 73), the suitability of any aBranch was 82.2% (60/73) and VBX was suitable in 64.4% of BCTs (47/73). The aBranch suitable patients had a significantly longer sinotubular-BCT length (P = .017) and smaller distal ascending aorta (P = .043) as compared with nonsuitable ones. The suitability of Terumo Aortic and Cook Medical devices was 52.1% (38/73) and 46.6% (34/73), respectively. When minor IFU criteria were ignored, suitability increased to 82.2% (60/73) and 63.0% (46/73), respectively. Left common carotid artery diameter and sinotubular-BCT length were significant nonsuitability risk factors for Terumo Aortic aBranch in multivariable analysis. No associations were found for Cook Medical device. The outcomes were tested in the entire cohort demonstrating a global suitability of 82.9%, increasing to 86.3% when ignoring minor IFUs. VBX was anatomically suitable to use in BCT in 73.2% of patient BCTs. CONCLUSIONS: aBranch devices are anatomically suitable in a vast majority of patients (86%) undergoing hybrid TEVAR. The innominate artery seems eligible for incorporation with VBX in almost two-thirds of patients. This mating stent may help to overcome some minor IFU restrictions.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Prótese Vascular , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Correção Endovascular de Aneurisma , Implante de Prótese Vascular/efeitos adversos , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/etiologia , Estudos Retrospectivos , Procedimentos Endovasculares/efeitos adversos , Desenho de Prótese , Stents , Resultado do Tratamento
4.
J Clin Med ; 12(21)2023 Oct 29.
Artigo em Inglês | MEDLINE | ID: mdl-37959301

RESUMO

BACKGROUND: The ultimate goal of treating patients with abdominal aortic aneurysms (AAAs) is to repair them when the risk of rupture exceeds the risk of repair. Small AAAs demonstrate a low rupture risk, and recently, large AAAs just above the threshold (5.5-6.0 cm) seem to be at low risk of rupture as well. The present review aims to investigate the outcomes of AAAs under surveillance through a comprehensive systematic review and meta-analysis. METHODS: PubMed, Embase, and the Cochrane Central Register were searched (22 March 2022; PROSPERO; #CRD42022316094). The Cochrane and PRISMA statements were respected. Blinded systematic screening of the literature, data extraction, and quality assessment were performed by two authors. Conflicts were resolved by a third author. The meta-analysis of prevalence provided estimated proportions, 95% confidence intervals, and measures of heterogeneity (I2). Based on I2, the heterogeneity might be negligible (0-40%), moderate (30-60%), substantial (50-90%), and considerable (75-100%). The primary outcome was the incidence of AAA rupture. Secondary outcomes included the rate of small AAAs reaching the threshold for repair, aortic-related mortality, and all-cause mortality. RESULTS: Fourteen publications (25,040 patients) were included in the analysis. The outcome rates of the small AAA group (<55 mm) were 0.3% (95% CI 0.0-1.0; I2 = 76.4%) of rupture, 0.6% (95% CI 0.0-1.9; I2 = 87.2%) of aortic-related mortality, and 9.6% (95% CI 2.2-21.1; I2 = 99.0%) of all-cause mortality. During surveillance, 21.4% (95% CI 9.0-37.2; I2 = 99.0%) of the initially small AAAs reached the threshold for repair. The outcome rates of the large AAA group (>55 mm) were 25.7% (95% CI 18.0-34.3; I2 = 72.0%) of rupture, 22.1% (95% CI 16.5-28.3; I2 = 25.0%) of aortic-related mortality, and 61.8% (95% CI 47.0-75.6; I2 = 89.1%) of all-cause mortality. The sensitivity analysis demonstrated a higher rupture rate in studies including <662 subjects, patients with a mean age > 72 years, >17% of female patients, and >44% of current smokers. CONCLUSION: The rarity of rupture and aortic-related mortality in small AAAs supports the current conservative management of small AAAs. Surveillance seems indicated, as one-fifth reached the threshold for repair. Large aneurysms had a high incidence of rupture and aortic-related mortality. However, these data seem biased by the sparse and heterogeneous literature overrepresented by patients unfit for surgery. Specific rupture risk stratified by age, gender, and fit-for-surgery patients with large AAAs needs to be further investigated.

6.
Acta Radiol ; 64(3): 945-950, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35918808

RESUMO

BACKGROUND: Incidental findings are common in abdominal computed tomography (CT) and often warrant further investigations with economic implications as well as implications for patients. PURPOSE: To evaluate the potential of dual-energy CT (DECT) in the identification and/or characterization of abdominal incidental mass lesions compared to conventional contrast-enhanced CT. MATERIAL AND METHODS: This retrospective study from a major tertiary hospital included 96 patients, who underwent contrast-enhanced abdominal DECT. Incidental lesions in adrenals, kidneys, liver, and pancreas were evaluated by two board-certified abdominal radiologists. Observer 1 only had access to standard CT reconstructions, while observer 2 had access to standard CT as well as DECT reconstructions. Disagreements were resolved by consensus review and used as a reference for observers using McNemar's test. RESULTS: Observers 1 and 2 identified a total of 40 and 34 findings, respectively. Furthermore, observer 1 registered 13 lesions requiring follow-up, of which seven (two renal and five adrenal lesions) were resolved following consensus review using DECT (P = 0.008). The inter-observer agreement was near perfect (κ = 0.82). CONCLUSION: DECT has the potential to improve the immediate characterization of incidental findings when compared to conventional CT for abdominal imaging.


Assuntos
Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Humanos , Estudos Retrospectivos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Abdome/diagnóstico por imagem , Fígado , Meios de Contraste
7.
J Surg Res ; 280: 209-217, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35994983

RESUMO

INTRODUCTION: Endovascular procedures have become commonplace in vascular surgery. This development calls for new training strategies for future specialists. Most simulation-based education (SBE) programs have a monodisciplinary focus on physicians, although successful surgery is a multidisciplinary team effort. Mental stress impairs the learning process and surgical performance and heart rate variability (HRV) can be measured as a proxy for both mental and physical stress. This study aims to assess how SBE of endovascular scrub nurses affects team performance and HRV during endovascular aneurysm repair (EVAR). MATERIALS AND METHODS: Prospective interventional study in which EVAR-inexperienced scrub nurses followed a focused SBE EVAR program. During real-life EVAR procedures, HRV was continuously recorded with a wireless electrocardiogram patch and multidisciplinary team performance was assessed with the Imperial College Error CAPture (ICECAP) tool, before and after the SBE program, allowing each scrub nurse to serve as their own control. Eight scrub nurses with experience in lower limb endovascular procedures, but not EVAR, were invited to participate. RESULTS: Seven participants completed the study. In five of seven scrub nurses, HRV-derived stress levels during real-time EVAR procedures were lower after SBE compared to before SBE. Mean HRV increased from 24 msec to 35 msec (P < 0.001), indicating stress level reduction. Before SBE, the mean number of errors/hour was 7.3 (standard deviation ± 1.8) compared to 3.6 (standard deviation ± 2.7) after SBE. Most errors were categorized as technical (58 %) and communicative (23 %). CONCLUSIONS: SBE of scrub nurses may improve team performance and may lower mental stress during EVAR procedures. In this small study, we suggest using mental stress, as evaluated with HRV, and multidisciplinary team performance, as evaluated with ICECAP, to assess SBE effectiveness in real-case EVAR procedures. This SBE program and live ICECAP observations and electrocardiogram patches was well-accepted by scrub nurses and the entire team.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Aneurisma da Aorta Abdominal/cirurgia , Procedimentos Endovasculares/métodos , Implante de Prótese Vascular/métodos , Estudos Prospectivos , Simulação por Computador
8.
Vasc Endovascular Surg ; 55(5): 495-500, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33511919

RESUMO

A 60-year male patient presented with a thoracoabdominal aortic aneurysm rupture, which was treated emergently with a modified off-the-shelf t-Branch stent-graft (COOK Medical Inc). The sole renal branch occluded 1 month after TEVAR due to branch compression, and the patient became anuric and temporarily dialysis-dependent. Despite the prolonged renal ischemia time, the occluded renal branch was successfully opened with thrombolysis and reinforced with a bare-metal stent. The patient recovered his renal function and came off dialysis.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Ruptura Aórtica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Obstrução da Artéria Renal/etiologia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Ruptura Aórtica/diagnóstico por imagem , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Procedimentos Endovasculares/instrumentação , Humanos , Masculino , Pessoa de Meia-Idade , Obstrução da Artéria Renal/diagnóstico por imagem , Obstrução da Artéria Renal/terapia , Diálise Renal , Stents , Terapia Trombolítica , Resultado do Tratamento
9.
Diagnostics (Basel) ; 10(10)2020 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-33066281

RESUMO

Dual-energy computed tomography (DECT) can estimate tissue vascularity and perfusion via iodine quantification. The aim of this systematic review was to outline current and emerging clinical applications of iodine quantification within the gastrointestinal tract using DECT. The search was conducted with three databases: EMBASE, Pubmed and The Cochrane Library. This identified 449 studies after duplicate removal. From a total of 570 selected studies, 30 studies were enrolled for the systematic review. The studies were categorized into four main topics: gastric tumors (12 studies), colorectal tumors (8 studies), Crohn's disease (4 studies) and miscellaneous applications (6 studies). Findings included a significant difference in iodine concentration (IC) measurements in perigastric fat between T1-3 vs. T4 stage gastric cancer, poorly and well differentiated gastric and colorectal cancer, responders vs. non-responders following chemo- or chemoradiotherapy treatment among cancer patients, and a positive correlation between IC and Crohn's disease activity. In conclusion, iodine quantification with DECT may be used preoperatively in cancer imaging as well as for monitoring treatment response. Future studies are warranted to evaluate the capabilities and limitations of DECT in splanchnic flow.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...