Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Scott Med J ; 58(1): e41-2, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23596039

RESUMO

We report on a patient with longstanding multicentric Castleman's disease, hyaline-vascular type, who presented with nearly-fatal myocarditis associated with a 2009 pandemic H1N1 influenza virus infection. This is the first case of such an association described in the literature.


Assuntos
Hiperplasia do Linfonodo Gigante/complicações , Vírus da Influenza A Subtipo H1N1 , Influenza Humana/complicações , Miocardite/complicações , Feminino , Humanos , Influenza Humana/epidemiologia , Pessoa de Meia-Idade , Miocardite/etiologia , Pandemias , Espanha
2.
J Viral Hepat ; 19(10): 711-5, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22967102

RESUMO

Transient elastography is a useful method to assess liver fibrosis, but uncertainties still exist regarding reliability and reproducibility of the technique. We aimed to improve knowledge on interobserver variability with the procedure and tried to find factors associated with such variability. This was a cross-sectional study to compare the results of transient elastography performed by two different operators, one test made just after the other. We assessed both results with correlation tests and with repeated parametric or nonparametric tests, as needed. We also carried out a multivariate analysis to find factors associated with discrepancy in the results obtained by the two operators. We included a total of 333 pairs of transient elastography tests, belonging to 274 different patients. A total of 325 pairs of tests (97.6%) were valid. Results of the first and the second tests were, respectively, median (and interquartile range) of direct measurement 6.2 (4.6-10.6) and 6.0 (4.4-10.1) kPa (P = 0.012), and mean ± standard deviation of log(10) of direct measurement 0.892 ± 0.316 and 0.871 ± 0.324 (P = 0.001). In 87 pairs of tests (26.7%), a discrepancy of at least 2 kPa between both results was found, and in 15 pairs of tests (4.6%), a discrepancy of at least 10 kPa was found. Discordance of at least one stage between both measurements was noted in 74 pairs of tests (22.8%). An association was found between higher stiffness and discrepancy between both operators (P < 0.001). Although transient elastography is a very convenient test to assess liver fibrosis in clinical practice, interobserver discrepancy in results is common and represents a significant problem with the technique. Discrepant results are more common in patients with higher values of stiffness.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Cirrose Hepática/diagnóstico , Adulto , Estudos Transversais , Humanos , Pessoa de Meia-Idade , Variações Dependentes do Observador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...