1.
Comb Chem High Throughput Screen ; 14(1): 22-7, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20958254

RESUMO

This paper describes a stripping method for the determination of nevirapine at the submicromolar concentration levels. The method is based on controlled adsorptive accumulation of nevirapine at thin-film mercury electrode, followed by a linear cyclic scan voltammetry measurement of the surface species. Optimal experimental conditions include a 2.0 x 10(-3) mol L(-1) NaOH solution (supporting electrolyte), an accumulation potential of -0.20 V, and a scan rate of 100 mV s(-1). The response of nevirapine is linear over the concentration range 0.01-0.14 ppm. For an accumulation time of 6 minutes, the detection limit was found to be 0.87 ppb (3.0 x 10(-9) mol L(-1)). More convenient methods to measure the nevirapine in presence of the efavirenz, acyclovir, didanosine, indinavir, nelfinavir, saquinavir, lamivudine, zidovudine and metals ions were also investigated. The utility of this method is demonstrated by the presence of nevirapine together with ATP or DNA.


Assuntos
Álcalis/química , Eletrodos , Eletrólitos/química , Mercúrio/química , Nevirapina/análise , Inibidores da Transcriptase Reversa/análise , Adsorção