1.
J Hazard Mater ; 475: 134853, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-38878431

RESUMO

Passive samplers are key tools to sample hydrophilic micropollutants in water. Two main approaches address the influence of hydrodynamics: (1) determining site-specific sampling rate (RS) by characterizing kw, the mass transfer coefficient of the water-boundary layer (WBL), and (2) reducing WBL impact using a diffusive material to control the uptake. The first requires calibration data and the second has only been achieved using fragile diffusive material. This study assesses the transfer of hydrophilic contaminants through polytetrafluoroethylene (PTFE; 30 µm thick), a new membrane material with lower sorption than commonly used polyethersulfone (PES). Combined for the first time in a Chemcatcher-like configuration, we calibrated the modified samplers for 44 micropollutants to provide RS - kw relationships for in-situ RS determination (approach 1). Micropollutants accumulated over 2000 times more on the sorbent than on PTFE. PTFE-based RS (0.027 to 0.300 L day-1) were 2.5 higher than previously reported with PES. Membrane property measurements (porosity, tortuosity) indicated that accumulation is primarily controlled by the membrane. Extrapolation indicated that using thicker PTFE membranes (≥ 100 µm) would shift uptake control entirely to the membrane in river conditions (approach 2). This finding could enable RS prediction based on contaminants properties, thus representing a significant advancement in passive sampling.

2.
Sci Total Environ ; 871: 162037, 2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-36740052

RESUMO

When monitoring water quality with hydrophilic integrative passive sampling devices, it is crucial to use accurate sampling rates (RS) that account for exposure conditions such as hydrodynamics. This study aims at calibrating Chemcatcher-like passive samplers - styrene-divinylbenzene reverse phase sulfonate (SDB-RPS) extraction disk covered by a polyethersulfone (PES) membrane - at four water flow velocities (5 to 40 cm s-1) in a channel system. First, the four hydrodynamic conditions were characterized by measuring the mass transfer coefficients of the water boundary layer (kw) at the surface of the samplers using the alabaster dissolution method. Then, fifty-six samplers were deployed in the channels and exposed for 7 different intervals varying from 1 to 21 days. Thus, RS were determined at four different kw for 44 hydrophilic compounds, ranging from 0.015 to 0.115 L day-1. Relationships were established between kw and RS using models for mixed rate control by the membrane and the water boundary layer. The estimated parameters of those relationships are suitable for the determination of accurate RS when kw is measured in situ, for example by co-deploying silicone disks spiked with performance and reference compounds (PRC) as implemented in Part B.

3.
Sci Total Environ ; 871: 161937, 2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-36736390

RESUMO

Integrative passive sampling is particularly useful in the monitoring of hydrophilic contaminants in surface water, but the impact of hydrodynamics on contaminant uptake still needs to be better considered. In part A (Glanzmann et al., 2023), Chemcatcher-like hydrophilic samplers (i.e., SDB-RPS extraction disks covered by PES microporous membranes) were calibrated to determine the sampling rates RS of 44 hydrophilic contaminants (pesticides, pharmaceuticals, industrial products) taking into account the hydrodynamic conditions. In this study, Chemcatcher-like passive sampling devices that allowed co-deploying hydrophilic samplers and performance reference compounds (PRC)-spiked silicone disks were tested in a Swiss river with intermediate water velocities (5-50 cm s-1, 23 cm s-1 on average) during 11 consecutive 14-day periods. The PRC dissipation from silicone disks - combined with the calibration data from part A - allowed to determine in-situ RS that took into account hydrodynamic conditions. The obtained aqueous time-weighted average (TWA) concentrations were found to be robust with good concordance between duplicates (mean quotient of 1.16 between the duplicates). For most measurements (76 %), TWA concentrations showed no major difference (20 cm s-1). RS from the literature (RS,LIT) - obtained at water velocities between 8 and 37 cm s-1 - were also shown to provide comparable TWA concentrations in the studied hydrodynamic conditions (average water velocity of 24 cm s-1). The estimated errors due to the use of RS,MAX or RS,LIT rather than in-situ RS are given as a function of the water velocity to determine in which conditions the developed method is required (or not) in monitoring programs.

4.
Environ Sci Technol ; 56(10): 6391-6398, 2022 05 17.
Artigo em Inglês | MEDLINE | ID: mdl-35420785

RESUMO

Passive sampling devices (PSDs) offer key benefits for monitoring chemical water quality, but the uptake process of PSDs for hydrophilic compounds still needs to be better understood. Determining mass transfer coefficients of the water boundary layer (kw) during calibration experiments and in situ monitoring would contribute toward achieving this; it allows for combining calibration data obtained at different temperature and hydrodynamic conditions and facilitate the translation of laboratory-derived calibration data to field exposure. This study compared two kw measurement methods applied to extraction disk housings (Chemcatcher), namely, alabaster dissolution and dissipation of performance reference compounds (PRCs) from silicone. Alabaster- and PRC-based kw were measured at four flow velocities (5-40 cm s-1) and two temperatures (11 and 20 °C) in a channel system. Data were compared using a relationship based on Sherwood, Reynolds, and Schmidt numbers. Good agreement was observed between data obtained at both temperatures, and for the two methods. Data were well explained by a model for mass transfer to a flat plate under laminar flow. It was slightly adapted to provide a semi-empirical model accounting for the effects of housing design on hydrodynamics. The use of PRC-spiked silicone to obtain in situ integrative kw for Chemcatcher-type PSDs is also discussed.


Assuntos
Monitoramento Ambiental , Poluentes Químicos da Água , Sulfato de Cálcio , Calibragem , Monitoramento Ambiental/métodos , Hidrodinâmica , Silicones , Poluentes Químicos da Água/química
5.
Sci Total Environ ; 811: 152139, 2022 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-34871677

RESUMO

3,4-Methylenedioxymethamphetamine (MDMA) and amphetamine are commonly used psychoactive stimulants. Illegal manufacture of these substances, mainly located in the Netherlands and Belgium, generates large amounts of chemical waste which is disposed in the environment or released in sewer systems. Retrospective analysis of high-resolution mass spectrometry (HRMS) data was implemented to detect synthesis markers of MDMA and amphetamine production in wastewater samples. Specifically, suspect and non-target screening, combined with a prioritization approach based on similarity measures between detected features and mass loads of MDMA and amphetamine was implemented. Two hundred and thirty-five 24 h-composite wastewater samples collected from a treatment plant in the Netherlands between 2016 and 2018 were analyzed by liquid chromatography coupled to high-resolution mass spectrometry. Samples were initially separated into two groups (i.e., baseline consumption versus dumping) based on daily loads of MDMA and amphetamine. Significance testing and fold-changes were used to find differences between features in the two groups. Then, associations between peak areas of all features and MDMA or amphetamine loads were investigated across the whole time series using various measures (Euclidian distance, Pearson's correlation coefficient, Spearman's rank correlation coefficient, distance correlation and maximum information coefficient). This unsupervised and unbiased approach was used for prioritization of features and allowed the selection of 28 presumed markers of production of MDMA and amphetamine. These markers could potentially be used to detect dumps in sewer systems, help in determining the synthesis route and track down the waste in the environment.


Assuntos
N-Metil-3,4-Metilenodioxianfetamina , Águas Residuárias , Anfetamina , Cromatografia Líquida , Estudos Retrospectivos , Detecção do Abuso de Substâncias
6.
Forensic Sci Int ; 325: 110883, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34229141

RESUMO

In post-mortem investigations of fatal intoxication, it is challenging to determine which drug(s) were responsible for the death, and which drugs did not. This study aims to provide post-mortem femoral blood drug levels in lethal intoxication and in post-mortem control cases, where the cause of death was other than intoxication. The reference values could assist in the interpretation of toxicological results in the routine casework. To this end, all post-mortem toxicological results in femoral blood from 2011 to 2017 in Western Switzerland were considered. A full autopsy with systematic toxicological analysis (STA) was conducted in all cases. Results take into account the cause of death classified into one of four categories (as published by Druid and colleagues): I) certified intoxication by one substance alone, IIa) certified intoxication by more than one substance, IIb) certified other causes of death with incapacitation due to drugs, and III) certified other causes of death without incapacitation due to drugs. This study includes 1 990 post-mortem cases where femoral blood was analysed. The material comprised 619 women (31%) and 1 371 men (69%) with a median age of 50 years. The concentrations of the 32 most frequently recorded substances as well as alcohol are discussed. These include 6 opioids and opiates, 3 antidepressants, 6 neuroleptics and hypnotics, 1 barbiturate, 11 benzodiazepines (and related drugs), 2 amphetamine-type stimulants, cocaine, paracetamol, and tetrahydrocannabinol (THC). The most common substances that caused intoxication alone were morphine, methadone, ethanol, tramadol, and cocaine. The post-mortem concentration ranges for all substance are categorized as I, IIa, IIb, or III. Statistical post-mortem reference concentrations for drugs are discussed and compared with previously published concentrations. This study shows that recording and classifying cases is time-consuming, but it is rewarding in a long-term perspective to achieve a more reliable information about fatal and non-fatal blood concentrations.


Assuntos
Depressores do Sistema Nervoso Central/sangue , Etanol/sangue , Drogas Ilícitas/sangue , Preparações Farmacêuticas/sangue , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Feminino , Toxicologia Forense , Humanos , Masculino , Pessoa de Meia-Idade , Mudanças Depois da Morte , Suíça , Adulto Jovem