Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Tipo de estudo
Intervalo de ano de publicação
1.
Biomed Opt Express ; 3(3): 407-17, 2012 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-22435090

RESUMO

We proposed and validated a compensation method that accounts for the optical distortion inherent in measuring displacements on specimens immersed in aqueous solution. A spherically-shaped rubber specimen was mounted and pressurized on a custom apparatus, with the resulting surface displacements recorded using electronic speckle pattern interferometry (ESPI). Point-to-point light direction computation is achieved by a ray-tracing strategy coupled with customized B-spline-based analytical representation of the specimen shape. The compensation method reduced the mean magnitude of the displacement error induced by the optical distortion from 35% to 3%, and ESPI displacement measurement repeatability showed a mean variance of 16 nm at the 95% confidence level for immersed specimens. The ESPI interferometer and numerical data analysis procedure presented herein provide reliable, accurate, and repeatable measurement of sub-micrometer deformations obtained from pressurization tests of spherically-shaped specimens immersed in aqueous salt solution. This method can be used to quantify small deformations in biological tissue samples under load, while maintaining the hydration necessary to ensure accurate material property assessment.

2.
Invest Ophthalmol Vis Sci ; 52(10): 7365-75, 2011 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-21791586

RESUMO

PURPOSE: IOP is the most common independent risk factor for development and progression of glaucoma, but very little is known about IOP dynamics. Continuous IOP telemetry was used in three nonhuman primates to characterize IOP dynamics at multiple time scales for multiple 24-hour periods. METHODS: An existing implantable telemetric pressure transducer system was adapted to monitoring anterior chamber IOP. The system records 500 IOP, ECG, and body temperature measurements per second and compensates for barometric pressure in real time. The continuous IOP signal was digitally filtered for noise and dropout and reported using time-window averaging for 19, 18, and 4 24-hour periods in three animals, respectively. Those data were analyzed for a nycthemeral pattern within each animal. RESULTS: Ten-minute time-window averaging for multiple 24-hour periods showed that IOP fluctuated from 7 to 14 mm Hg during the day, and those changes occurred frequently and quickly. Two-hour time-window averages of IOP for multiple 24-hour periods in three animals showed a weak nycthemeral trend, but IOP was not repeatable from day-to-day within animals. CONCLUSIONS: The measured IOP was successfully measured continuously by using a new, fully implantable IOP telemetry system. IOP fluctuates as much as 10 mm Hg from day to day and hour to hour in unrestrained nonhuman primates, which indicates that snapshot IOP measurements may be inadequate to capture the true dynamic character of IOP. The distributions, magnitudes, and patterns of IOP are not reproducible from day to day within animals, but IOP tends to be slightly higher at night when IOP data are averaged across multiple 24-hour periods within animals.


Assuntos
Ritmo Circadiano/fisiologia , Pressão Intraocular/fisiologia , Telemetria/instrumentação , Animais , Temperatura Corporal , Eletrocardiografia , Feminino , Macaca mulatta , Próteses e Implantes , Telemetria/métodos , Transdutores de Pressão
3.
Invest Ophthalmol Vis Sci ; 50(10): 4709-18, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19443718

RESUMO

PURPOSE: To investigate spectral domain optical coherence tomography (SD-OCT)-detected optic disc margin anatomy in the monkey eye by colocalizing disc photographs to SD-OCT scans acquired from the same eyes. METHODS: The neural canal opening (NCO) was delineated within 40 digital radial sections generated from SD-OCT volumes acquired from 33 normal monkey eyes (15 degrees, 290 x 768 horizontal grid pattern). Each volume was colocalized to its disc photograph by matching the retinal vessels within each photograph to vessel outlines visible within en face SD-OCT images. Border tissue was delineated where it extended internally to the NCO. A clinician (masked to delineated points) marked the disc margin onto each photograph while viewing the relevant stereophotograph pair. Alignment of the clinician-ascribed disc margin to the NCO and border tissue delineation was assessed. The process was repeated in a single myopic human eye. RESULTS: In 23 eyes, the NCO aligned to the disc margin. In 10 eyes, externally oblique border tissue was detectable in the temporal disc. In these regions of the disc, the termination of border tissue was the disc margin. An exaggerated form of this phenotype was observed in the myopic human eye. In this case, temporal border tissue terminated at the anterior scleral canal opening, which was detected as the disc margin. CONCLUSIONS: The termination of Bruch's membrane, border tissue, and the anterior scleral canal opening may constitute the disc margin within the same eye, depending on the border tissue architecture; this anatomy is consistently visualized by SD-OCT.


Assuntos
Disco Óptico/anatomia & histologia , Tomografia de Coerência Óptica/métodos , Animais , Macaca mulatta , Nervo Óptico/anatomia & histologia , Fotografação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...