1.
IEEE Trans Med Imaging ; 37(4): 1058-1066, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29621003

RESUMO

We are developing a 1-mm3 resolution, high-sensitivity positron emission tomography (PET) system for loco-regional cancer imaging. The completed system will comprise two cm detector panels and contain 4 608 position sensitive avalanche photodiodes (PSAPDs) coupled to arrays of mm3 LYSO crystal elements for a total of 294 912 crystal elements. For the first time, this paper summarizes the design and reports the performance of a significant portion of the final clinical PET system, comprising 1 536 PSAPDs, 98 304 crystal elements, and an active field-of-view (FOV) of cm. The sub-system performance parameters, such as energy, time, and spatial resolutions are predictive of the performance of the final system due to the modular design. Analysis of the multiplexed crystal flood histograms shows 84% of the crystal elements have>99% crystal identification accuracy. The 511 keV photopeak energy resolution was 11.34±0.06% full-width half maximum (FWHM), and coincidence timing resolution was 13.92 ± 0.01 ns FWHM at 511 keV. The spatial resolution was measured using maximum likelihood expectation maximization reconstruction of a grid of point sources suspended in warm background. The averaged resolution over the central 6 cm of the FOV is 1.01 ± 0.13 mm in the X-direction, 1.84 ± 0.20 mm in the Y-direction, and 0.84 ± 0.11 mm in the Z-direction. Quantitative analysis of acquired micro-Derenzo phantom images shows better than 1.2 mm resolution at the center of the FOV, with subsequent resolution degradation in the y-direction toward the edge of the FOV caused by limited angle tomography effects.


Assuntos
Tomografia por Emissão de Pósitrons/instrumentação , Tomografia por Emissão de Pósitrons/métodos , Desenho de Equipamento , Humanos , Imagens de Fantasmas
2.
Phys Med Biol ; 61(18): 6733-6753, 2016 09 21.
Artigo em Inglês | MEDLINE | ID: mdl-27551981

RESUMO

Cadmium zinc telluride (CZT) offers key advantages for small animal positron emission tomography (PET), including high spatial and energy resolution and simple metal deposition for fabrication of very small pixel arrays. Previous studies have investigated the intrinsic spatial, energy, and timing resolution of an individual sub-millimeter resolution CZT detector. In this work we present the first characterization results of a system of these detectors. The 3D position sensitive dual-CZT detector module and readout electronics developed in our lab was scaled up to complete a significant portion of the final PET system. This sub-system was configured as two opposing detection panels containing a total of twelve [Formula: see text] mm monolithic CZT crystals for proof of concept. System-level characterization studies, including optimizing the trigger threshold of each channel's comparators, were performed. 68Ge and 137Cs radioactive isotopes were used to characterize the energy resolution of all 468 anode channels in the sub-system. The mean measured global 511 keV photopeak energy resolution over all anodes was found to be [Formula: see text]% FWHM after correction for photon interaction depth-dependent signal variation. The measured global time resolution was 37 ns FWHM, a parameter to be further optimized, and the intrinsic spatial resolution was 0.76 mm FWHM.


Assuntos
Cádmio , Eletrônica/instrumentação , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/instrumentação , Tomografia por Emissão de Pósitrons/instrumentação , Telúrio , Zinco , Animais , Eletrônica/métodos , Humanos , Imageamento Tridimensional/métodos , Fótons , Tomografia por Emissão de Pósitrons/métodos
3.
IEEE Trans Med Imaging ; 30(2): 391-400, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20876008

RESUMO

We are developing a dual panel breast-dedicated positron emission tomography (PET) system using LSO scintillators coupled to position sensitive avalanche photodiodes (PSAPD). The charge output is amplified and read using NOVA RENA-3 ASICs. This paper shows that the coincidence timing resolution of the RENA-3 ASIC can be improved using certain list-mode calibrations. We treat the calibration problem as a convex optimization problem and use the RENA-3's analog-based timing system to correct the measured data for time dispersion effects from correlated noise, PSAPD signal delays and varying signal amplitudes. The direct solution to the optimization problem involves a matrix inversion that grows order (n(3)) with the number of parameters. An iterative method using single-coordinate descent to approximate the inversion grows order (n). The inversion does not need to run to convergence, since any gains at high iteration number will be low compared to noise amplification. The system calibration method is demonstrated with measured pulser data as well as with two LSO-PSAPD detectors in electronic coincidence. After applying the algorithm, the 511 keV photopeak paired coincidence time resolution from the LSO-PSAPD detectors under study improved by 57%, from the raw value of 16.3 ±0.07 ns full-width at half-maximum (FWHM) to 6.92 ±0.02 ns FWHM ( 11.52 ±0.05 ns to 4.89 ±0.02 ns for unpaired photons).


Assuntos
Algoritmos , Tomografia por Emissão de Pósitrons/instrumentação , Tomografia por Emissão de Pósitrons/métodos , Calibragem , Modelos Teóricos , Processamento de Sinais Assistido por Computador
4.
Phys Med Biol ; 55(23): 7149-74, 2010 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-21081831

RESUMO

A 1 mm(3) resolution clinical positron emission tomography (PET) system employing 4608 position-sensitive avalanche photodiodes (PSAPDs) is under development. This paper describes a detector multiplexing technique that simplifies the readout electronics and reduces the density of the circuit board design. The multiplexing scheme was validated using a simulation framework that models the PSAPDs and front-end multiplexing circuits to predict the signal-to-noise ratio and flood histogram performance. Two independent experimental setups measured the energy resolution, time resolution, crystal identification ability and count rate both with and without multiplexing. With multiplexing, there was no significant degradation in energy resolution, time resolution and count rate. There was a relative 6.9 ± 1.0% and 9.4 ± 1.0% degradation in the figure of merit that characterizes the crystal identification ability observed in the measured and simulated ceramic-mounted PSAPD module flood histograms, respectively.


Assuntos
Luz , Modelos Teóricos , Tomografia por Emissão de Pósitrons/instrumentação , Cerâmica , Eletrodos , Humanos
5.
IEEE Trans Neural Netw ; 18(3): 889-901, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17526353

RESUMO

Implementation of real-time neural network inversion on the SRC-6e, a computer that uses multiple field-programmable gate arrays (FPGAs) as reconfigurable computing elements, is examined using a sonar application as a specific case study. A feedforward multilayer perceptron neural network is used to estimate the performance of the sonar system (Jung et al., 2001). A particle swarm algorithm uses the trained network to perform a search for the control parameters required to optimize the output performance of the sonar system in the presence of imposed environmental constraints (Fox et al., 2002). The particle swarm optimization (PSO) requires repetitive queries of the neural network. Alternatives for implementing neural networks and particle swarm algorithms in reconfigurable hardware are contrasted. The final implementation provides nearly two orders of magnitude of speed increase over a state-of-the-art personal computer (PC), providing a real-time solution.


Assuntos
Computadores , Metodologias Computacionais , Modelos Teóricos , Redes Neurais de Computação , Reconhecimento Automatizado de Padrão/métodos , Processamento de Sinais Assistido por Computador/instrumentação , Inteligência Artificial , Simulação por Computador , Sistemas Computacionais , Desenho de Equipamento , Análise de Falha de Equipamento
6.
Eur J Gastroenterol Hepatol ; 16(2): 235-7, 2004 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15076002

RESUMO

Coeliac disease and hereditary haemochromatosis are genetic disorders paradoxically associated with altered intestinal absorption of iron. Hereditary haemochromatosis is the most common autosomal recessive disease in the Caucasian population and is characterised by an iron overload state. Coeliac disease, or gluten sensitive enteropathy, on the other hand is frequently associated with iron deficiency anaemia. We report the cases of two patients who developed both coeliac disease and hereditary haemochromatosis. We review the literature of this rare association and examine how the clinical presentation is modified by their co-existence and the potential genetic linkage of these two disorders.


Assuntos
Doença Celíaca/complicações , Hemocromatose/genética , Doença Celíaca/metabolismo , Feminino , Hemocromatose/metabolismo , Humanos , Ferro/metabolismo , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...