Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nano Lett ; 19(11): 7935-7940, 2019 11 13.
Artigo em Inglês | MEDLINE | ID: mdl-31647666

RESUMO

Magnetic resonance force microscopy (MRFM) is a scanning probe technique capable of detecting MRI signals from nanoscale sample volumes, providing a paradigm-changing potential for structural biology and medical research. Thus far, however, experiments have not reached sufficient spatial resolution for retrieving meaningful structural information from samples. In this work, we report MRFM imaging scans demonstrating a resolution of 0.9 nm and a localization precision of 0.6 nm in one dimension. Our progress is enabled by an improved spin excitation protocol furnishing us with sharp spatial control on the MRFM imaging slice, combined with overall advances in instrument stability. From a modeling of the slice function, we expect that our arrangement supports spatial resolutions down to 0.3 nm given sufficient signal-to-noise ratio. Our experiment demonstrates the feasibility of subnanometer MRI and realizes an important milestone toward the three-dimensional imaging of macromolecular structures.

2.
Nano Lett ; 17(4): 2367-2373, 2017 04 12.
Artigo em Inglês | MEDLINE | ID: mdl-28329445

RESUMO

Charge transport in nanostructures and thin films is fundamental to many phenomena and processes in science and technology, ranging from quantum effects and electronic correlations in mesoscopic physics, to integrated charge- or spin-based electronic circuits, to photoactive layers in energy research. Direct visualization of the charge flow in such structures is challenging due to their nanometer size and the itinerant nature of currents. In this work, we demonstrate noninvasive magnetic imaging of current density in two-dimensional conductor networks including metallic nanowires and carbon nanotubes. Our sensor is the electronic spin of a diamond nitrogen-vacancy center attached to a scanning tip and operated under ambient conditions. Using a differential measurement technique, we detect DC currents down to a few µA with a current density noise floor of ∼2 × 104 A/cm2. Reconstructed images have a spatial resolution of typically 50 nm, with a best-effort value of 22 nm. Current density imaging offers a new route for studying electronic transport and conductance variations in two-dimensional materials and devices, with many exciting applications in condensed matter physics and materials science.

3.
J Phys Condens Matter ; 25(17): 176004, 2013 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-23567900

RESUMO

We study the effect of magnetocrystalline anisotropy on the magnetic configurations of La0.7Sr0.3MnO3 bar and triangle elements using photoemission electron microscopy imaging. The dominant remanent state is a low energy flux-closure state for both thin (15 nm) and thick (50 nm) elements. The magnetocrystalline anisotropy, which competes with the dipolar energy, causes a strong modification of the spin configuration in the thin elements, depending on the shape, size and orientation of the structures. We investigate the magnetic switching processes and observe in triangular shaped elements a displacement of the vortex core along the easy axis for an external magnetic field applied close to the hard axis, which is well reproduced by micromagnetic simulations.

4.
Rev Sci Instrum ; 81(11): 113707, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21133478

RESUMO

Studying the interaction of spin-polarized currents with the magnetization configuration is of high interest due to the possible applications and the novel physics involved. High-resolution magnetic imaging is one of the key techniques necessary for a better understanding of these effects. Here, we present an extension to a magnetic microscope that allows for in situ current injection into the structure investigated, and furthermore for the study of current induced magnetization changes during pulsed current injection. The developed setup is highly flexible and can be used for a wide range of investigations. Examples of current-induced domain wall motion and vortex core displacements measured using this setup are presented.

5.
Phys Rev Lett ; 105(5): 056601, 2010 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-20867942

RESUMO

Using transmission electron microscopy, we investigate the thermally activated motion of domain walls (DWs) between two positions in Permalloy (Ni80Fe20) nanowires at room temperature. We show that this purely thermal motion is well described by an Arrhenius law, allowing for a description of the DW as a quasiparticle in a one-dimensional potential landscape. By injecting small currents, the potential is modified, allowing for the determination of the nonadiabatic spin torque: ßt=0.010±0.004 for a transverse DW and ßv=0.073±0.026 for a vortex DW. The larger value is attributed to the higher magnetization gradients present.

6.
Phys Rev Lett ; 105(7): 076601, 2010 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-20868064

RESUMO

We study the depinning of domain walls by pure diffusive spin currents in a nonlocal spin valve structure based on two ferromagnetic Permalloy elements with copper as the nonmagnetic spin conduit. The injected spin current is absorbed by the second Permalloy structure with a domain wall, and from the dependence of the wall depinning field on the spin current density we find an efficiency of 6×10{-14} T/(A/m{2}), which is more than an order of magnitude larger than for conventional current induced domain-wall motion. Theoretically we find that this high efficiency arises from the surface torques exerted by the absorbed spin current that lead to efficient depinning.

7.
Phys Rev Lett ; 104(6): 067201, 2010 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-20366851

RESUMO

Using photoemission electron microscopy, we image the dynamics of a field pulse excited domain wall in a Permalloy nanowire. We find a delay in the onset of the wall motion with respect to the excitation and an oscillatory relaxation of the domain wall back to its equilibrium position, defined by an external magnetic field. The origin of both of these inertia effects is the transfer of energy between energy reservoirs. By imaging the distribution of the exchange energy in the wall spin structure, we determine these reservoirs, which are the basis of the domain wall mass concept.

8.
Phys Rev Lett ; 105(18): 187203, 2010 Oct 29.
Artigo em Inglês | MEDLINE | ID: mdl-21231132

RESUMO

We use a pump-probe photoemission electron microscopy technique to image the displacement of vortex cores in Permalloy discs due to the spin-torque effect during current pulse injection. Exploiting the distinctly different symmetries of the spin torques and the Oersted-field torque with respect to the vortex spin structure we determine the torques unambiguously, and we quantify the amplitude of the strongly debated nonadiabatic spin torque. The nonadiabaticity parameter is found to be ß=0.15±0.07, which is more than an order of magnitude larger than the damping constant α, pointing to strong nonadiabatic transport across the high magnetization gradient vortex spin structures.

9.
Phys Rev Lett ; 99(9): 097203, 2007 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-17931031

RESUMO

Magnetization reversal in a periodic magnetic field is studied on an ultrathin, ultrasoft ferromagnetic Pt/Co(0.5 nm)/Pt trilayer exhibiting weak random domain wall (DW) pinning. The DW motion is imaged by polar magneto-optic Kerr effect microscopy and monitored by superconducting quantum interference device susceptometry. In close agreement with model predictions, the complex linear ac susceptibility corroborates the dynamic DW modes segmental relaxation, creep, slide, and switching.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...