Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 368
Filtrar
1.
J Clin Med ; 13(12)2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38930026

RESUMO

Background/Objectives: To date, data regarding the characteristics and management of obstructive, stable coronary artery disease (CAD) encountered in patients undergoing transcatheter aortic valve implantation (TAVI) are sparse. The aim of the study was to analyze granular details, treatment, and outcomes of patients undergoing TAVI with obstructive, stable CAD from real-world practice. Methods: REVASC-TAVI (Management of myocardial REVASCularization in patients undergoing Transcatheter Aortic Valve Implantation with coronary artery disease) is an investigator-initiated, multicenter registry, which collected data from patients undergoing TAVI with obstructive stable CAD found during the pre-TAVI work-up. Results: A total of 2025 patients from 30 centers worldwide with complete follow-up were included in the registry. Most patients had single-vessel CAD (56.1%). An involvement of proximal coronary tracts was detected in 62.5% of cases, with 12.0% of patients having CAD in left main (LM). Most patients received percutaneous coronary intervention (PCI) (n = 1617, 79.9%), especially those with proximal CAD (90.4%). At 2 years, the rates of all-cause death [Kaplan-Meier (KM) estimates 20.1% vs. 18.8%, plog-rank = 0.86] and of the composite of all-cause death, stroke, myocardial infarction, and rehospitalization for heart failure (KM estimates 29.7% vs. 27.5%, plog-rank = 0.82) did not differ between patients undergoing PCI and those who were not. Conclusions: Patients undergoing TAVI with obstructive CAD more commonly had a single-vessel disease and an involvement of proximal coronary tracts. They were commonly treated with PCI, with similar outcomes compared to those treated conservatively.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38775442

RESUMO

Coronary physiological assessment has garnered extensive application in managing patients with coronary artery disease, encompassing both acute and chronic scenarios. Beyond the historical purpose as tool to define the hemodynamic significance of a given artery lesion, coronary artery physiology allows for a complete investigation of epicardial and microvascular circulation. The longitudinal assessment of the distribution pattern of coronary disease based on pressure wire technology provides crucial information to define the best management and procedural planning. Moreover, post-percutaneous coronary intervention physiology reassessment showed a strong association with clinical outcomes and, more importantly, it can spot residual pressure gradients potentially amenable to further intervention and optimization. Growing evidence about the non-invasive angiography-based indices helps to overcome the limitations of the use of intracoronary physiology. This review aims to provide an overview of different utilizations of coronary physiology offering a historical perspective with a particular focus on current challenges and future potential applications.

4.
Cardiovasc Toxicol ; 24(6): 550-562, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38696070

RESUMO

Trastuzumab is widely used in HER2 breast cancer. However, it may cause left ventricular (LV) dysfunction. A decrease in LV global longitudinal strain (GLS) has been previously demonstrated to be a good predictor of subsequent cancer therapy related dysfunction (CTRCD). Left atrial morphological remodeling during Trastuzumab therapy has also been shown. The aim of this study is exploring the relationship between early changes in left atrial function and the development of Trastuzumab-induced cardiotoxicity. Consecutive patients with diagnosis of HER2+non-metastatic breast cancer treated with Trastuzumab were prospectively enrolled. A clinical, conventional, and advanced echocardiographic assessment was performed at baseline and every three months, until a one-year follow-up was reached. One-hundred-sixteen patients completed the 12 months follow-up, 10 (9%) cases of CTRCD were observed, all after the sixth month. GLS and LVEF significantly decreased in the CTRCD group at 6 months of follow-up, with an earlier (3 months) significant worsening in left atrial morpho-functional parameters. Systolic blood pressure, early peak atrial longitudinal strain (PALS), peak atrial contraction (PACS) and left atrial volume (LAVI) changes resulted independent predictors of CTRCD at multivariable logistic regression analysis. Moreover, early changes in PALS and PACS resulted good predictors of CTRCD development (AUC 0.85; p = 0.008, p < 0.001 and 0.77; p = 0.008, respectively). This prospective study emphasizes that the decline in PALS and PACS among trastuzumab-treated patients could possibly increase the accuracy in identifying future CTRCD in non-metastatic HER2 breast cancer cases, adding predictive value to conventional echocardiographic assessment.


Assuntos
Antineoplásicos Imunológicos , Função do Átrio Esquerdo , Neoplasias da Mama , Cardiotoxicidade , Receptor ErbB-2 , Trastuzumab , Função Ventricular Esquerda , Humanos , Trastuzumab/efeitos adversos , Feminino , Neoplasias da Mama/tratamento farmacológico , Pessoa de Meia-Idade , Receptor ErbB-2/metabolismo , Estudos Prospectivos , Antineoplásicos Imunológicos/efeitos adversos , Função Ventricular Esquerda/efeitos dos fármacos , Função do Átrio Esquerdo/efeitos dos fármacos , Adulto , Fatores de Tempo , Fatores de Risco , Resultado do Tratamento , Idoso , Valor Preditivo dos Testes , Medição de Risco , Remodelamento Atrial/efeitos dos fármacos , Cardiopatias/induzido quimicamente , Cardiopatias/fisiopatologia , Cardiopatias/diagnóstico por imagem , Disfunção Ventricular Esquerda/induzido quimicamente , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Átrios do Coração/efeitos dos fármacos , Átrios do Coração/fisiopatologia , Átrios do Coração/diagnóstico por imagem , Volume Sistólico/efeitos dos fármacos
5.
Int J Cardiol ; 407: 132113, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-38697398

RESUMO

BACKGROUND: Axillary vein puncture (AVP) is a valid alternative to Subclavan vein puncture for leads insertion in cardiac implantable electronic device implantation, that may reduce acute and delayed complications. Very few data are available about ICD recipients. A simplified AVP technique is described. METHODS: All the patients who consecutively underwent "de novo" ICD implantation, from March 2006 to December 2020 at the University of Verona, were considered. Leads insertion was routinely performed through an AVP, according to a simplified technique. Outcome and complications have been retrospectively analyzed. RESULTS: The study population consisted of 1711 consecutive patients. Out of 1711 patients, 38 (2.2%) were excluded because they were implanted with Medtronic Sprint Fidelis lead. Out of 1673 ICD implantations, 963 (57.6%) were ICD plus cardiac resynchronization therapy, 434 (25.9%) were dual-chamber defibrillators, and 276 (16.5%) were single-chamber defibrillators, for a total of 3879 implanted leads. The AVP success rate was 99.4%. Acute complications occurred in 7/1673 (0.42%) patients. Lead failure (LF) occurred in 20/1673 (1.19%) patients. Comparing the group of patients with lead failure with the group without LF, the presence of three leads inside the vein was significantly associated with LF, and the multivariate analysis confirmed three leads in place as an independent predictor of LF. CONCLUSION: AVP, according to our simplified technique, is safe, effective, has a high success rate, and a very low complication rate. The incidence of LF was exceptionally low. The advantages of AVP are maintained over time in a population of ICD recipients.


Assuntos
Veia Axilar , Desfibriladores Implantáveis , Punções , Humanos , Desfibriladores Implantáveis/efeitos adversos , Masculino , Feminino , Estudos Retrospectivos , Idoso , Pessoa de Meia-Idade , Veia Axilar/diagnóstico por imagem , Implantação de Prótese/métodos , Implantação de Prótese/efeitos adversos , Implantação de Prótese/instrumentação , Resultado do Tratamento , Fatores de Tempo
6.
JACC Cardiovasc Interv ; 17(10): 1187-1199, 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38811101

RESUMO

Calcified nodules (CNs) are among the most challenging lesions to treat in contemporary percutaneous coronary intervention. CNs may be divided into 2 subtypes, eruptive and noneruptive, which have distinct histopathological and prognostic features. An eruptive CN is a biologically active lesion with a disrupted fibrous cap and possibly adherent thrombus, whereas a noneruptive CN has an intact fibrous cap and no adherent thrombus. The use of intravascular imaging may allow differentiation between the 2 subtypes, thus potentially guiding treatment strategy. Compared with noneruptive CNs, eruptive CNs are more likely to be deformable, resulting in better stent expansion, but are paradoxically associated with worse clinical outcomes, in part because of their frequent initial presentation as an acute coronary syndrome and subsequent reprotrusion of the CN into the vessel lumen through the stent struts. Pending the results of ongoing studies, a tailored therapeutic approach based on the distinct features of the different CNs may be of value.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Stents , Calcificação Vascular , Humanos , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/efeitos adversos , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/terapia , Resultado do Tratamento , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Fatores de Risco , Valor Preditivo dos Testes , Vasos Coronários/diagnóstico por imagem , Placa Aterosclerótica , Ultrassonografia de Intervenção , Angiografia Coronária , Tomada de Decisão Clínica
7.
EuroIntervention ; 20(8): e504-e510, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38629420

RESUMO

The treatment of coronary artery disease (CAD) in patients with severe aortic valve stenosis (AVS) eligible for transcatheter aortic valve implantation (TAVI) is not supported by clinical evidence, and the role of physiology over anatomy as well as the timing of coronary intervention are not defined. FAITAVI (ClinicalTrials.gov: NCT03360591) is a nationwide prospective, open-label, multicentre, randomised controlled study comparing the angiography-guided versus the physiology-guided coronary revascularisation strategy in patients with combined significant CAD and severe AVS undergoing TAVI. Significant CAD will be defined as coronary stenosis ≥50%, as assessed by visual estimation in vessels ≥2.5 mm. Physiology will be tested by fractional flow reserve (FFR) and instantaneous wave-free ratio (iFR). The study will be conducted at 15 sites in Italy. In the angiography arm, percutaneous coronary intervention (PCI) will be performed either before TAVI, during the TAVI procedure - before or after the valve implantation - or within 1 month±5 days of the valve implantation, left to the operator's decision. In the physiology arm, FFR and iFR will be performed before TAVI, and PCI will be indicated for FFR ≤0.80, otherwise the intervention will be deferred. In case of borderline values (0.81-0.85), FFR and iFR will be repeated after TAVI, with PCI performed when needed. With a sample size of 320 patients, the study is powered to evaluate the primary endpoint (a composite of death, myocardial infarction, stroke, major bleeding, or ischaemia-driven target vessel revascularisation). TAVI indication, strategy and medical treatment will be the same in both groups. After discharge, patients will be contacted at 1, 6, 12 and 24 months after the procedure to assess their general clinical status, and at 12 months for the occurrence of events included in the primary and secondary endpoints. FAITAVI is the first randomised clinical trial to investigate "optimal" percutaneous coronary intervention associated with TAVI in patients with severe AVS and CAD.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Humanos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Estudos Prospectivos , Resultado do Tratamento , Estudos Multicêntricos como Assunto , Ensaios Clínicos Controlados Aleatórios como Assunto
8.
Am J Cardiol ; 221: 102-109, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38636623

RESUMO

Transcatheter aortic valve implantation (TAVI) is an established treatment strategy in aortic valve disease. Infolding, as a nonuniform expansion of the prosthesis leading to introflection of part of the device circumference, is a complication specific to self-expandable prostheses. The aim of the study is to determine incidence, predictors, treatment strategy, and outcomes of infolding during Medtronic Evolut TAVI (Minneapolis, MN, US). Between January 2018 and March 2022, all patients treated with Evolut TAVI were included in a multicenter observational retrospective study. According to the occurrence of infolding, the enrolled cohort was divided into 2 groups; periprocedural characteristics and 30-day outcomes were compared. A total of 1,470 patients were included; 23 infolding cases (1.6%) were detected. Preprocedural imaging showed larger aortic anatomy and greater calcium burden in the infolding group. Infolding occurred mostly with Evolut Pro+ and size 34 mm and was diagnosed before full prosthesis release in 78.3%. The rate of moderate-to-severe paravalvular regurgitation was higher in the infolding group (21.7% vs 1.9%, p <0.001). Short-term follow-up showed greater all-cause and cardiovascular mortality (respectively, 4.3% vs 0.7% and 4.3% vs 0.6%, p <0.05) and higher rate of pacemaker implantation (33.3% vs 15.7%, p = 0.042) in case of infolding. High right cusp calcium score and resheathing maneuvers were independent predictors of infolding. In conclusion, prosthesis infolding is a TAVI complication burdened by worse cardiovascular outcomes. Prompt intraprocedural infolding diagnosis is pivotal, especially in case of great native valve calcium burden and resheathing maneuvers, to safely overcome this complication by prosthesis recapture or postdilation.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Desenho de Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Incidência , Idoso , Falha de Prótese , Complicações Pós-Operatórias/epidemiologia , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/epidemiologia
9.
Curr Cardiol Rep ; 26(5): 359-372, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38619711

RESUMO

PURPOSE OF REVIEW: Acute coronary syndromes (ACS) are a major global health concern. Percutaneous coronary intervention (PCI) with new-generation drug-eluting stents (DES) has been endorsed as safe and effective in the management of culprit and non-culprit lesions of ACS. However, permanent metallic implants may have drawbacks, including the need for prolonged dual antiplatelet therapy (DAPT) and the risk of long-term stent-related complications. An alternative approach using drug-coated balloons (DCBs) is gaining growing interest, having the potential of delivering therapy directly to vulnerable plaques, avoiding the need for permanent metallic implants, and potentially allowing for better long-term medical treatment. Despite limited evidence, DCB is being explored in several patients' subgroups. This review aims to discuss the existing evidence regarding DCB in ACS management. RECENT FINDINGS: DCB appears to be a promising strategy in the management of ACS, showing comparable angiographic and clinical results as compared to new-generation DES in relatively small clinical trials or large prospective registries. The advantage of avoiding permanent implants is particularly appealing in this setting, where DCB has the potential of delivering anti-atherogenic local therapy directly to vulnerable plaques still amenable to atherogenic regression. This review seeks to underline the theoretical background of DCB use and reports the available evidence in its support in the specific setting of ACS. In the context of ACS, the use of DCB is highly attractive, offering a dedicated anti-atherogenic local therapy, capable of addressing a broad range of vulnerable plaques and patients.


Assuntos
Síndrome Coronariana Aguda , Angioplastia Coronária com Balão , Stents Farmacológicos , Humanos , Síndrome Coronariana Aguda/terapia , Resultado do Tratamento , Intervenção Coronária Percutânea/métodos , Materiais Revestidos Biocompatíveis , Inibidores da Agregação Plaquetária/uso terapêutico
10.
JACC Cardiovasc Interv ; 17(5): 681-692, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38479968

RESUMO

BACKGROUND: The performance of latest iteration transcatheter aortic valve replacement platforms in patients with small aortic anatomy remains underexplored. OBJECTIVES: The aim of this study was to evaluate effectiveness and performance between the self-expanding (SE) Evolut PRO and PRO+ and the balloon-expandable (BE) SAPIEN ULTRA in patients with small aortic annuli. METHODS: Data from the OPERA-TAVI (Comparative Analysis of Evolut PRO vs. SAPIEN 3 ULTRA Valves for Transfemoral Transcatheter Aortic Valve Implantation) registry were used, with 1:1 propensity score matching. Primary endpoints included 1-year effectiveness composite (all-cause mortality, disabling stroke, or heart failure hospitalization) and 30-day device-related (hemodynamic structural valve dysfunction and nonstructural valve dysfunction) outcomes. RESULTS: Among 3,516 patients, 251 matched pairs with aortic annular area <430 mm2 were assessed. The 1-year primary effectiveness outcome did not differ significantly between cohorts (SE 10.8% vs BE 11.2%; P = 0.91). The 30-day device-oriented composite outcome was more favorable in the Evolut PRO group (SE 4.8% vs BE 10.4%; P = 0.027). Notably, SE valve recipients showed higher rates of disabling stroke (SE 4.0% vs BE 0.0%; P < 0.01) and paravalvular leaks (mild or greater: SE 48.5% vs BE 18.6% [P < 0.001]; moderate: SE 4.5% vs BE 1.2% [P = 0.070]). The BE group had higher rates of prosthesis-patient mismatch (moderate or greater: SE 16.0% vs BE 47.1% [P < 0.001]; severe: SE 1.3% vs BE 5.7% [P = 0.197]) and more patients with residual mean gradients >20 mm Hg (SE 1.0% vs BE 13.5%; P < 0.001). CONCLUSIONS: In patients with small aortic annuli, transcatheter aortic valve replacement with latest iteration devices is safe. SE platforms are associated with more favorable device performance in terms of hemodynamic structural and nonstructural dysfunction. Randomized data are needed to validate these findings and guide informed device selection.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Desenho de Prótese , Resultado do Tratamento , Sistema de Registros , Acidente Vascular Cerebral/etiologia
11.
Am J Cardiol ; 217: 144-152, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38431052

RESUMO

Coronary angiography (CA) is poorly correlated with non-invasive myocardial stress imaging (NSI) and myocardial ischemia is often observed in patients with unobstructed coronary arteries. Moreover, the diagnostic performance of combined epicardial and microcirculatory angiography-derived physiological assessment and its correlation with NSI remains unknown. A total of 917 coronary vessels in 319 patients who underwent both CA and NSI were included in this multicenter observational retrospective analysis. Quantitative flow ratio (QFR) and angiography-derived index of microcirculatory resistance (IMRangio) analyses were performed to estimate coronary epicardial and microcirculatory function respectively. NSI demonstrated evidence of myocardial ischemia in 76% of the cases. IMRangio (36 [22 to 50] vs 29 [21 to 41], p <0.001) was significantly higher and QFR (0.92 [0.78 to 0.99] vs 0.97 [0.91 to 0.99], p <0.001) was significantly lower in vessels subtending ischemic territories. Overall, the diagnostic accuracy of QFR was moderate (area under the curve of receiver operating characteristic [AUCROC] 0.632 [95% confidence interval [CI] 0.589 to 0.674], p <0.0001) but it was higher in patients with normal microcirculatory function (AUCROC = 0.726 [95% CI 0.669 to 0.784], p <0.0001, p Value for AUCROC comparison = 0.009). Combined QFR/IMRangio assessment provided incremental diagnostic performance compared with the evaluation of epicardial or microcirculatory districts in isolation (p Value for AUC comparison <0.0001) and it was able to identify the predominant mechanism of myocardial ischemia in 77% of the patients with positive NSI. Our study suggests the value of a combined angiography-derived assessment of epicardial and microvascular function for the definition of the predominant mechanism of myocardial ischemia in patients with suspected coronary artery disease.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Isquemia Miocárdica , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico , Estudos Retrospectivos , Microcirculação , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Angiografia Coronária/métodos , Isquemia Miocárdica/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Valor Preditivo dos Testes
12.
JACC Case Rep ; 29(9): 102287, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38500538

RESUMO

The long-established utility of multiwindow interrogation in echocardiography (suprasternal notch, right and left sternal border, apex, and subxiphoid) is sometimes not systematically implemented in routine practice. This case series emphasizes the pivotal importance of such practice for the systematic assessment of aortic valve stenosis and in the evaluation of left ventricular outflow tract and the aorta.

13.
JACC Cardiovasc Interv ; 17(6): 742-752, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38538170

RESUMO

BACKGROUND: Coronary obstruction (CO) is a potentially life-threatening complication of transcatheter aortic valve replacement (TAVR). Chimney stenting or leaflet laceration with transcatheter electrosurgery (Bioprosthetic or Native Aortic Scallop Intentional Laceration to Prevent Iatrogenic Coronary Artery Obstruction [BASILICA]) are 2 techniques developed to prevent CO. OBJECTIVES: The aim of the present study was to compare periprocedural and 1-year outcomes of chimney and BASILICA in TAVR patients at high risk of CO. METHODS: This multicenter observational registry enrolled consecutive TAVR patients at high risk of CO, undergoing either preventive chimney stenting or BASILICA. Clinical success was defined as successful performance of the chimney or BASILICA technique without clinically relevant ostial CO. The primary endpoint was major adverse cardiovascular events, a composite of death, myocardial infarction, stroke, or unplanned target lesion coronary revascularization at 1 year. RESULTS: A total of 168 patients were included: 71 (42.3%) received chimney stenting, and 97 (57.7%) underwent BASILICA. Patients undergoing BASILICA had higher preprocedural risk of CO, as indicated by lower sinotubular junction height (18.2 ± 4.8 mm vs 14.8 ± 3.4 mm; P < 0.001) and diameter (28.2 ± 4.5 vs 26.8 ± 3.4; P = 0.029). Rates of periprocedural complications were similar between the 2 groups. Clinical success was 97.2% and 96.9% in chimney and BASILICA, respectively (P = 0.92). At 1-year follow-up, the cumulative incidence of major adverse cardiovascular events was 18.7% (95% CI: 11%-30.6%) in the chimney group and 19.9% (95% CI: 12.1%-31.5%) in the BASILICA group (log-rank P = 0.848), whereas chimney was associated with a numerically higher cardiovascular mortality than BASILICA (6.7% vs 1.3%; log-rank P = 0.168). CONCLUSIONS: Chimney stenting and BASILICA effectively prevent TAVR-induced acute CO. Both techniques seem to have comparable acceptable periprocedural and 1-year outcomes.


Assuntos
Estenose da Valva Aórtica , Oclusão Coronária , Próteses Valvulares Cardíacas , Lacerações , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Lacerações/complicações , Lacerações/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Resultado do Tratamento , Oclusão Coronária/etiologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Desenho de Prótese
14.
Minerva Cardiol Angiol ; 72(4): 313-328, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38535984

RESUMO

Renal denervation (RDN) is a safe and effective strategy for the treatment of difficult to treat hypertension. The blood pressure (BP)-lowering efficacy of RDN is comparable to those of many single antihypertensive medications and it allows to consider the RDN as a valuable option for the treatment of difficult to treat hypertension together with lifestyle modifications and medical therapy. A multidisciplinary team is of pivotal importance from the selection of the patient candidate for the procedure to the post-procedural management. Further studies are needed to investigate the effect of RDN on clinical outcomes and to better identify the predictors of BP response to RDN in order to recognize the patients who are more likely to benefit from the procedure.


Assuntos
Anti-Hipertensivos , Hipertensão , Rim , Simpatectomia , Humanos , Anti-Hipertensivos/uso terapêutico , Pressão Sanguínea/efeitos dos fármacos , Cardiologia , Denervação/métodos , Hipertensão/terapia , Hipertensão/cirurgia , Itália , Rim/inervação , Simpatectomia/métodos
15.
Circ Cardiovasc Interv ; 17(3): e013556, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38375667

RESUMO

BACKGROUND: Patients with ST-segment-elevation myocardial infarction but no coronary microvascular injury are at low risk of early cardiovascular complications (ECC). We aim to assess whether nonhyperemic angiography-derived index of microcirculatory resistance (NH-IMRangio) could be a user-friendly tool to identify patients at low risk of ECC, potentially candidates for expedited care pathway and early hospital discharge. METHODS: Retrospective analysis of 2 independent, international, prospective, observational cohorts included 568 patients with ST-segment-elevation myocardial infarction. NH-IMRangio was calculated based on standard coronary angiographic views with 3-dimensional-modeling and computational analysis of the coronary flow. RESULTS: Overall, ECC (a composite of cardiovascular death, cardiogenic shock, acute heart failure, life-threatening arrhythmias, resuscitated cardiac arrest, left ventricular thrombus, post-ST-segment-elevation myocardial infarction mechanical complications, and rehospitalization for acute heart failure or acute myocardial infarction at 30 days follow-up), occurred in 54 (9.3%) patients. NH-IMRangio was significantly correlated with pressure/thermodilution-based index of microcirculatory resistance (r=0.607; P<0.0001) and demonstrated good accuracy in predicting ECC (area under the curve, 0.766 [95% CI, 0.706-0.827]; P<0.0001). Importantly, ECC occurred more frequently in patients with NH-IMRangio ≥40 units (18.1% versus 1.4%; P<0.0001). At multivariable analysis, NH-IMRangio provided incremental prognostic value to conventional clinical, angiographic, and echocardiographic features (adjusted-odds ratio, 14.861 [95% CI, 5.177-42.661]; P<0.0001). NH-IMRangio<40 units showed an excellent negative predictive value (98.6%) in ruling out ECC. Discharging patients with NH-IMRangio<40 units at 48 hours after admission would reduce the total in-hospital stay by 943 days (median 2 [1-4] days per patient). CONCLUSIONS: NH-IMRangio is a valuable risk-stratification tool in patients with ST-segment-elevation myocardial infarction. NH-IMRangio guided strategies to early discharge may contribute to safely shorten hospital stay, optimizing resources utilization.


Assuntos
Insuficiência Cardíaca , Infarto do Miocárdio , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Angiografia Coronária , Vasos Coronários/diagnóstico por imagem , Insuficiência Cardíaca/etiologia , Microcirculação , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/terapia , Infarto do Miocárdio/etiologia , Alta do Paciente , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Estudos Retrospectivos , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Infarto do Miocárdio com Supradesnível do Segmento ST/etiologia , Resultado do Tratamento , Estudos Observacionais como Assunto
16.
Am J Cardiol ; 219: 60-70, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38401656

RESUMO

Evidence regarding gender-related differences in response to transcatheter aortic valve implantation according to the valve type is lacking. This study aimed to evaluate the impact of gender on the treatment effect of Evolut PRO/PRO+ (PRO) or SAPIEN 3 Ultra (ULTRA) devices on clinical outcomes. The Comparative Analysis of Evolut PRO vs SAPIEN 3 Ultra Valves for Transfemoral Transcatheter Aortic Valve Implantation (OPERA-TAVI) is a multicenter, multinational registry including patients who underwent the latest-iteration PRO or ULTRA implantation. Overall, 1,174 of 1,897 patients were matched based on valve type and compared according to gender, whereas 470 men and 630 women were matched and compared according to valve type. The 30-day and 1-year outcomes were evaluated. In the PRO and ULTRA groups, men had a higher co-morbidity burden, whereas women had smaller aortic root. The 30-day (device success [DS], early safety outcome, permanent pacemaker implantation, patient-prosthesis mismatch, paravalvular regurgitation, bleedings, vascular complications, and all-cause death) and 1-year outcomes (all-cause death, stroke, and heart failure hospitalization) did not differ according to gender in both valve groups. However, the male gender decreased the likelihood of 30-day DS with ULTRA versus PRO (p for interaction = 0.047). A higher risk of 30-day permanent pacemaker implantation and 1-year stroke and a lower risk of patient-prosthesis mismatch was observed in PRO versus ULTRA, regardless of gender. In conclusion, gender did not modify the treatment effect of PRO versus ULTRA on clinical outcomes, except for 30-day DS, which was decreased in men (vs women) who received ULTRA (vs PRO).


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Desenho de Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Masculino , Feminino , Estenose da Valva Aórtica/cirurgia , Fatores Sexuais , Idoso de 80 Anos ou mais , Idoso , Resultado do Tratamento , Complicações Pós-Operatórias/epidemiologia , Valva Aórtica/cirurgia
17.
Eur Heart J Cardiovasc Imaging ; 25(7): 947-957, 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38319610

RESUMO

AIMS: We sought to investigate the association of left atrial strain with the outcome in a large cohort of patients with at least moderate aortic stenosis (AS). METHODS AND RESULTS: We analysed 467 patients (mean age 80.6 ± 8.2 years; 51% men) with at least moderate AS and sinus rhythm. The primary study endpoint was the composite of all-cause mortality and hospitalizations for heart failure. After a median follow-up of 19.2 (inter-quartile range 12.5-24.4) months, 96 events occurred. Using the receiver operator characteristic curve analysis, the cut-off value of peak atrial longitudinal strain (PALS) more strongly associated with outcome was <16% {area under the curve (AUC) 0.70 [95% confidence interval (CI): 0.63-0.78], P < 0.001}. The Kaplan-Meier curves demonstrated a higher rate of events for patients with PALS < 16% (log-rank P < 0.001). On multivariable analysis, PALS [adjusted HR (aHR) 0.95 (95% CI 0.91-0.99), P = 0.017] and age were the only variables independently associated with the combined endpoint. PALS provided incremental prognostic value over left ventricular (LV) global longitudinal strain, LV ejection fraction, and right ventricular function. Subgroup analysis revealed that impaired PALS was also independently associated with outcome in the subgroups of paucisymptomatic patients [aHR 0.98 (95% CI 0.97-0.98), P = 0.048], moderate AS [aHR 0.92, (95% CI 0.86-0.98), P = 0.016], and low-flow AS [aHR 0.90 (95% CI 0.83-0.98), P = 0.020]. CONCLUSION: In our patients with at least moderate AS, PALS was independently associated with outcome. In asymptomatic patients, PALS could be a potential marker of sub-clinical damage, leading to better risk stratification and, potentially, earlier treatment.


Assuntos
Estenose da Valva Aórtica , Índice de Gravidade de Doença , Humanos , Masculino , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/mortalidade , Feminino , Medição de Risco , Idoso , Idoso de 80 Anos ou mais , Prognóstico , Estudos de Coortes , Ecocardiografia/métodos , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/fisiopatologia , Estudos Retrospectivos , Função do Átrio Esquerdo/fisiologia , Estimativa de Kaplan-Meier , Curva ROC , Causas de Morte
18.
Eur J Heart Fail ; 26(3): 581-589, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38404225

RESUMO

AIMS: Dilated cardiomyopathy (DCM) with arrhythmic phenotype combines phenotypical aspects of DCM and predisposition to ventricular arrhythmias, typical of arrhythmogenic cardiomyopathy. The definition of DCM with arrhythmic phenotype is not universally accepted, leading to uncertainty in the identification of high-risk patients. This study aimed to assess the prognostic impact of arrhythmic phenotype in risk stratification and the correlation of arrhythmic markers with high-risk arrhythmogenic gene variants in DCM patients. METHODS AND RESULTS: In this multicentre study, DCM patients with available genetic testing were analysed. The following arrhythmic markers, present at baseline or within 1 year of enrolment, were tested: unexplained syncope, rapid non-sustained ventricular tachycardia (NSVT), ≥1000 premature ventricular contractions/24 h or ≥50 ventricular couplets/24 h. LMNA, FLNC, RBM20, and desmosomal pathogenic or likely pathogenic gene variants were considered high-risk arrhythmogenic genes. The study endpoint was a composite of sudden cardiac death and major ventricular arrhythmias (SCD/MVA). We studied 742 DCM patients (45 ± 14 years, 34% female, 410 [55%] with left ventricular ejection fraction [LVEF] <35%). During a median follow-up of 6 years (interquartile range 1.6-12.1), unexplained syncope and NSVT were the only arrhythmic markers associated with SCD/MVA, and the combination of the two markers carried a significant additive risk of SCD/MVA, incremental to LVEF and New York Heart Association class. The probability of identifying an arrhythmogenic genotype rose from 8% to 30% if both early syncope and NSVT were present. CONCLUSION: In DCM patients, the combination of early detected NSVT and unexplained syncope increases the risk of life-threatening arrhythmic outcomes and can aid the identification of carriers of malignant arrhythmogenic genotypes.


Assuntos
Cardiomiopatia Dilatada , Morte Súbita Cardíaca , Fenótipo , Humanos , Feminino , Cardiomiopatia Dilatada/genética , Cardiomiopatia Dilatada/fisiopatologia , Cardiomiopatia Dilatada/diagnóstico , Cardiomiopatia Dilatada/complicações , Masculino , Pessoa de Meia-Idade , Prognóstico , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Adulto , Medição de Risco/métodos , Síncope/genética , Síncope/etiologia , Síncope/fisiopatologia , Arritmias Cardíacas/genética , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/diagnóstico , Volume Sistólico/fisiologia , Taquicardia Ventricular/genética , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/diagnóstico , Testes Genéticos/métodos
20.
JACC Cardiovasc Interv ; 17(3): 374-387, 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38180419

RESUMO

BACKGROUND: The COVID-19 pandemic adversely affected health care systems. Patients in need of transcatheter aortic valve replacement (TAVR) are especially susceptible to treatment delays. OBJECTIVES: This study sought to evaluate the impact of the COVID-19 pandemic on global TAVR activity. METHODS: This international registry reported monthly TAVR case volume in participating institutions prior to and during the COVID-19 pandemic (January 2018 to December 2021). Hospital-level information on public vs private, urban vs rural, and TAVR volume was collected, as was country-level information on socioeconomic status, COVID-19 incidence, and governmental public health responses. RESULTS: We included 130 centers from 61 countries, including 65,980 TAVR procedures. The first and second pandemic waves were associated with a significant reduction of 15% (P < 0.001) and 7% (P < 0.001) in monthly TAVR case volume, respectively, compared with the prepandemic period. The third pandemic wave was not associated with reduced TAVR activity. A greater reduction in TAVR activity was observed in Africa (-52%; P = 0.001), Central-South America (-33%; P < 0.001), and Asia (-29%; P < 0.001). Private hospitals (P = 0.005), urban areas (P = 0.011), low-volume centers (P = 0.002), countries with lower development (P < 0.001) and economic status (P < 0.001), higher COVID-19 incidence (P < 0.001), and more stringent public health restrictions (P < 0.001) experienced a greater reduction in TAVR activity. CONCLUSIONS: TAVR procedural volume declined substantially during the first and second waves of the COVID-19 pandemic, especially in Africa, Central-South America, and Asia. National socioeconomic status, COVID-19 incidence, and public health responses were associated with treatment delays. This information should inform public health policy in case of future global health crises.


Assuntos
Estenose da Valva Aórtica , COVID-19 , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Pandemias , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/epidemiologia , Resultado do Tratamento , COVID-19/epidemiologia , Sistema de Registros , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...