Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Biomech Eng ; 145(10)2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37219841

RESUMO

Biomechanical testbench emulating the physiological loading of the pelvis is crucial in developing reconstructive implants for fragility fractures of the pelvis. Additionally, it will help understand the influence of the common daily loading on the pelvic ring. However, most reported experimental studies were mainly comparative with simplified loading and boundary conditions. In Part I of our study, we described the concept of the computational experiment design to design and construct a biomechanical testbench emulating the gait movement of the pelvis. The 57 muscles and joints' contact forces were reduced to four force actuators and one support, producing a similar stress distribution. The experimental setup is explained in this paper and some experimental results are presented. In addition, a series of repeatability and reproducibility tests were conducted to assess the test stand capabilities of replicating the gait physiological loading. The calculated stresses and the experimentally recorded strains showed that the pelvic ring response to the loading always follows the loaded leg side during the gait cycle. Furthermore, the experimental results of the pelvis displacement and strain at selected locations match the numerical ones. The developed test stand and the concept of computational experiment design behind it provide guidelines on how to design biomechanical testing equipment with physiological relevance.


Assuntos
Marcha , Pelve , Reprodutibilidade dos Testes , Fenômenos Biomecânicos , Pelve/fisiologia , Marcha/fisiologia , Fenômenos Mecânicos
2.
J Biomech Eng ; 145(10)2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37199569

RESUMO

Biomechanics of the human pelvis and the associated implants are still a medical and engineering debated topic. Today, no biomechanical testing setup is dedicated to pelvis testing and associated reconstructive implants with accepted clinical relevance. This paper uses the computational experiment design procedure to numerically design a biomechanical test stand that emulates the pelvis physiological gait loading. The numerically designed test stand reduces the 57 muscles and joints' contact forces iteratively to only four force actuators. Two hip joints' contact forces and two equivalent muscle forces with a maximum magnitude of 2.3 kN are applied in a bilateral reciprocating action. The stress distribution of the numerical model of the developed test stand is very similar to that of the numerical model of the pelvis with all 57 muscles and joint forces. For instance, at the right arcuate line, the state of stress is identical. However, at the location of superior rami, there is a deviation ranging from 2% to 20% between the two models. The boundary conditions and the nature of loading adopted in this study are more realistic regarding the clinical relevance than state-of-the-art. The numerically developed biomechanical testing setup of the pelvis in this numerical study (Part I) was found to be valid for the experimental testing of the pelvis. The construct of the testing setup and the experimental testing of an intact pelvis under gait loading are discussed in detail in Part II: Experimental Testing.


Assuntos
Articulação do Quadril , Pelve , Humanos , Pelve/fisiologia , Articulação do Quadril/fisiologia , Marcha/fisiologia , Músculos , Fenômenos Mecânicos , Fenômenos Biomecânicos
3.
Int J Numer Method Biomed Eng ; 36(4): e3319, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32017442

RESUMO

This study focuses on the influence of the softening and stiffening of pubic symphysis on the load distribution within the bones of the pelvic ring under the physiological loadings of the single leg stance. Muscle forces and joint reaction forces were first determined by inverse dynamics and applied to a linear finite element model of the pelvis. With normal pubic symphysis stiffness, high Von Mises stresses are located on the anterior surface to the sacrum around the sacroiliac joint and on the superior ramus, both on the side of the weight-bearing leg. Softening of the pubic symphysis redirects the load backward, decreases the stresses at the anterior pelvis, and increases them at the posterior pelvis. A stiffening of the pubic symphysis redirects the load forward, increases the load on the posterior pelvis, and decreases them at the anterior pelvis. This investigation highlights the significance of the pubic symphysis on the load distribution of the pelvis and in maintaining the integrity of the structures. Its role should not be neglected when analyzing the pelvis.


Assuntos
Análise de Elementos Finitos , Humanos , Pelve/fisiologia , Sínfise Pubiana/fisiologia , Suporte de Carga/fisiologia
4.
J Exp Orthop ; 5(1): 33, 2018 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-30178260

RESUMO

BACKGROUND: The objective of the study is to investigate the load transmission within the pelvic ring under physiological loading during gait and to correlate these results with clinical findings. In a second approach, we analysed how load distribution is altered by fractures of the anterior pelvic ring. METHODS: Muscle forces and joint reaction forces are calculated by inverse dynamics and implemented in a finite element pelvis model including the joints. RESULTS: With the intact configuration and according to the moment of the gait, left and right superior and inferior rami show the highest stresses of the model, corresponding to the typical location of an anterior pelvic ring fracture. A superior ramus fracture induces larger stresses to the lower ramus and a slight increase of stresses on the posterior structures. A total disruption of anterior rami redirects the loads to the back of the pelvis and introduces significantly higher stresses on the posterior structures. CONCLUSIONS: This investigation enhances the understanding of the biomechanics of the pelvis and highlights the important role of the rami in load carrying and in maintaining integrity of the pelvic ring.

5.
Int Sch Res Notices ; 2015: 439095, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-27347518

RESUMO

The present paper deals with the design, the repeatability, and the comparison to literature data of a new measuring device called "Rotameter" to characterize the rotational knee laxity or the tibia-femoral rotation (TFR). The initial prototype P1 of the Rotameter is shortly introduced and then modified according to trials carried out on a prosthetic leg and on five healthy volunteers, leading therefore to an improved prototype P2. A comparison of results obtained from P1 and P2 with the same male subject shows the enhancements of P2. Intertester and intratester repeatability of this new device were shown and it was observed that rotational laxities of left and right knees are the same for a healthy subject. Moreover, a literature review showed that measurements with P2 presented lower TFR values than other noninvasive devices. The measured TFR versus torque characteristic was quite similar to other invasive devices, which are more difficult to use and harmful to the patient. Hence, our prototype P2 proved to be an easy-to-use and suitable device for quantifying rotational knee laxity. A forthcoming study will validate the Rotameter thanks to an approach based on computed tomography in order to evaluate its precision.

6.
Int Sch Res Notices ; 2015: 705201, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-27347541

RESUMO

The purpose of this study is to validate a noninvasive rotational knee laxity measuring device called "Rotameter P2" with an approach based on Computed Tomography (CT). This CT-approach using X-rays is hence invasive and can be regarded as a precise reference method that may also be applied to similar devices. An error due to imperfect femur fixation was observed but can be neglected for small torques. The most significant estimation error is due to the unavoidable soft tissues rotation and hence flexibility in the measurement chain. The error increases with the applied torque. The assessment showed that the rotational knee angle measured with the Rotameter is still overestimated because of thigh and femur displacement, soft tissues deformation, and measurement artefacts adding up to a maximum of 285% error at +15 Nm for the Internal Rotation of female volunteers. This may be questioned if such noninvasive devices for measuring the Tibia-Femoral Rotation (TFR) can help diagnosing knee pathologies and investigate ligament reconstructive surgery.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...