Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Appl Opt ; 61(11): 2957-2966, 2022 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-35471271

RESUMO

The standard uncertainty of detector-based radiance and irradiance responsivity calibrations in the short-wave infrared (SWIR) traditionally has been limited to around 1% or higher by the poor spatial uniformity of detectors used to transfer the scale from radiant power. Pyroelectric detectors offer a solution that avoids the spatial uniformity uncertainty but also introduces additional complications due to alternating current (AC) measurement techniques. Herein, a new, to the best of our knowledge, method for low uncertainty irradiance responsivity calibrations in the SWIR is presented. An absolute spectral irradiance responsivity scale was placed on two pyroelectric detectors (PED) at wavelengths λ from 500 to 3400 nm. The total combined uncertainty (k=1) was ≈0.28% (>1000nm), 0.44% (900 nm), and 0.36% (≈950nm and <900nm) for PED #1 and 0.34% (>1000nm), 0.48% (900 nm), and 0.42% (≈950nm and <900nm) for PED #2. This was done by utilizing a demodulation technique to digitally analyze the time-dependent AC waveforms, which obviates the use of lock-in amplifiers and avoids associated additional uncertainty components.

2.
J Biomed Opt ; 20(12): 121309, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26502383

RESUMO

A hyperspectral image projector (HIP) based on liquid crystal on silicon spatial light modulators is explained and demonstrated to generate data cubes. The HIP-constructed data cubes are three-dimensional images of the spatial distribution of spectrally resolved abundances of intracellular light-absorbing oxyhemoglobin molecules in single erythrocytes. Spectrally and spatially resolved image data indistinguishable from the real scene may be used as standard data cubes, so-called digital phantoms, to calibrate image sensors and validate image analysis algorithms for their measurement quality, performance consistency, and interlaboratory comparisons for quantitative biomedical imaging applications.

3.
J Biomed Opt ; 20(12): 121309, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26361340

RESUMO

A hyperspectral image projector (HIP) based on liquid crystal on silicon spatial light modulators is explained and demonstrated to generate data cubes. The HIP-constructed data cubes are three-dimensional images of the spatial distribution of spectrally resolved abundances of intracellular light-absorbing oxyhemoglobin molecules in single erythrocytes. Spectrally and spatially resolved image data indistinguishable from the real scene may be used as standard data cubes, so-called digital phantoms, to calibrate image sensors and validate image analysis algorithms for their measurement quality, performance consistency, and interlaboratory comparisons for quantitative biomedical imaging applications.


Assuntos
Anticorpos Antibacterianos/imunologia , Proteínas da Membrana Bacteriana Externa/imunologia , Vacinas Bacterianas/imunologia , Infecções Meningocócicas/imunologia , Neisseria meningitidis/imunologia , Humanos
4.
Biomed Opt Express ; 3(6): 1433-45, 2012 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-22741088

RESUMO

Hyperspectral imaging has the potential to achieve high spatial resolution and high functional sensitivity for non-invasive assessment of tissue oxygenation. However, clinical acceptance of hyperspectral imaging in ischemic wound assessment is hampered by its poor reproducibility, low accuracy, and misinterpreted biology. These limitations are partially caused by the lack of a traceable calibration standard. We proposed a digital tissue phantom (DTP) platform for quantitative calibration and performance evaluation of spectral wound imaging devices. The technical feasibility of such a DTP platform was demonstrated by both in vitro and in vivo experiments. The in vitro DTPs were developed based on a liquid blood phantom model. The in vivo DTPs were developed based on a porcine ischemic skin flap model. The DTPs were projected by a Hyperspectral Image Projector (HIP) with high fidelity. A wide-gap 2nd derivative oxygenation algorithm was developed to reconstruct tissue functional parameters from hyperspectral measurements. In this study, we have demonstrated not only the technical feasibility of using DTPs for quantitative calibration, evaluation, and optimization of spectral imaging devices but also its potential for ischemic wound assessment in clinical practice.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...