ASAIO J ; 55(3): 271-6, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19318921

RESUMO

The objective of this study was to test different pulsatile flow settings of the PediVAS centrifugal pump to seek an optimum setting for pulsatile flow to achieve better pulsatile energy and minimal backflow. The PediVAS centrifugal pump and the conventional pediatric clinical circuit, including a pediatric membrane oxygenator, arterial filter, arterial cannula, and 1/4 in circuit tubing were used. The circuit was primed with 40% glycerin water mixture. Postcannula pressure was maintained at 40 mm Hg by a Hoffman clamp. The experiment was conducted at 800 ml/min of pump flow with a modified pulsatile flow setting at room temperature. Pump flow and pressure readings at preoxygenator and precannula sites were simultaneously recorded by a data acquisition system. The results showed that backflows appeared at flow rates of 200-800 ml/min (200 ml/min increments) with the default pulsatile flow setting and only at 200 ml/min with the modified pulsatile flow setting. With an increased rotational speed difference ratio and a decreased pulsatile width, the pulsatility increased in terms of surplus hemodynamic energy and total hemodynamic energy at preoxygenator and precannula sites. Backflows seemed at preoxygenator and precannula sites at a 70% of rotational speed difference ratio. The modified pulsatile flow setting was better than the default pulsatile flow setting in respect to pulsatile energy and backflow. The pulsatile width and the rotational speed difference ratio significantly affected pulsatility. The parameter of the rotational speed difference ratio can automatically increase pulsatility with increased rotational speeds. Further studies will be conducted to optimize the pulsatile flow setting of the centrifugal pump.


Assuntos
Coração Auxiliar , Fluxo Pulsátil/fisiologia
2.
ASAIO J ; 55(1): 100-5, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19092653

RESUMO

The study objective was to evaluate the Jostra HL-20 roller pump under different baseflow and pump head settings with quantified energy values from pressure and flow waveforms, in a simulated pediatric bypass circuit. Pump flow rate was set at 800 mL/min for both pulsatile and nonpulsatile perfusion modes and the mean arterial pressure (MAP) of the pseudopatient was maintained at 40 mm Hg for each experiment. Pulsatile baseflow settings and pump head start points varied with each experiment. Pressure and flow waveforms were recorded at preoxygenator, precannula, and postcannula sites under each pump setting. A total of 91 experiments were performed (n=7, nonpulsatile; n=84, pulsatile). Increasing baseflow caused decreases in the mean circuit pressure and surplus hemodynamic energy (SHE) levels for all pump head start times. When increasing pump head start time within each baseflow, values for MAP and SHE increased significantly. Regardless of baseflow or pump head start time, values for mean circuit pressure and SHE were lower for nonpulsatile flow than for pulsatile flow. Total hemodynamic energy values were also significantly higher under pulsatile perfusion and increased pump start times while decreasing with increased baseflows in the circuit. This study concludes that decreased baseflows with increased pump head settings on the Jostra HL-20 roller pump could significantly increase quality of generated pulsatile energy. Further research is necessary to evaluate these various pump settings under microembolic loads and with different circuit components.


Assuntos
Oxigenação por Membrana Extracorpórea , Coração Auxiliar , Fluxo Pulsátil/fisiologia , Ponte Cardiopulmonar/instrumentação , Criança , Oxigenação por Membrana Extracorpórea/instrumentação , Humanos
3.
ASAIO J ; 55(1): 106-10, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19092661

RESUMO

The hemodynamic comparison of the Jostra HL-20 and the Levitronix PediVAS blood pumps is the focus this study, where pressure-flow waveforms and hemodynamic energy values are analyzed in the confines of a pediatric cardiopulmonary bypass circuit.The pseudo pediatric patient was perfused with flow rates between 500 and 900 ml/min (100 ml/min increments) under pulsatile and nonpulsatile mode. The Levitronix continuous flow pump utilized a customized controller to engage in pulsatile perfusion with equivalent pulse settings to the Jostra HL-20 roller pump. Hemodynamic measurements and waveforms were recorded at the precannula location, while the mean arterial pressure was maintained at 40 mm Hg for each test. Glycerin water was used as the blood analog circuit perfusate. At each flow rate 24 trials were conducted yielding a total of 120 experiments (n=60 pulsatile and n=60 nonpulsatile).Under nonpulsatile perfusion the Jostra roller pump produced small values for surplus hemodynamic energy (SHE) due to its inherent pulsatility, while the Levitronix produced values of essentially zero for SHE. When switching to pulsatile perfusion, the SHE levels for both the Jostra and Levitronix pump made considerable increases. In comparing the two pumps under pulsatile perfusion, the Levitronix PediVAS produced significantly more surplus and total hemodynamic energy than did the Jostra roller pump each pump flow rate.The study suggests that the Levitronix PediVAS centrifugal pump has the capability of achieving quality pulsatile waveforms and delivering more SHE to the pseudo patient than the Jostra HL-20 roller pump. Further studies are warranted to investigate the Levitronix under bovine blood studies and with various pulsatile settings.


Assuntos
Ponte Cardiopulmonar/instrumentação , Circulação Extracorpórea/instrumentação , Coração Auxiliar , Fluxo Pulsátil/fisiologia , Humanos , Lactente
4.
ASAIO J ; 54(5): 529-33, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18812747

RESUMO

This study aims to compare the Jostra HL-20 roller pump to the Medos DeltaStream DP1 rotary pump in terms of pressure and flow waveforms, as well as calculated energies based on pressure/flow relationships, in a simulated pediatric cardiopulmonary perfusion system. The flow rate was set at 1,000 ml/min for each pump, under both pulsatile and nonpulsatile perfusion modes. Mean arterial pressure (MAP) was maintained at 40 mm Hg. Pressure and flow measurements and waveforms were recorded at precannula site in the bypass circuit. Blood analog test fluid was used to simulate blood properties. A total of 24 experiments were performed (n = 12 nonpulsatile and n = 12 pulsatile). A significant increase in surplus hemodynamic energy (SHE) was observed in both pumps under pulsatile perfusion. In contrast, nonpulsatile perfusion generated very little SHE in the Jostra roller pump, whereas no SHE was generated in the Medos rotary pump. However, under pulsatile perfusion, the Medos rotary pump generated more than twice the amount of SHE or "extra" energy than the Jostra roller pump. The total hemodynamic energy was also significantly higher in the Medos rotary pump than the Jostra roller pump, under pulsatile perfusion. This pilot study suggests that the Medos DeltaStream DP1 rotary pump may produce greater hemodynamic energy levels and higher quality physiologic pressure/flow waveforms than the Jostra roller pump. Further investigation of the Medos DeltaStream DP1 rotary pump is necessary to evaluate hemodynamic energy generation under various pump settings, in contrast to different flow rates.


Assuntos
Ponte Cardiopulmonar/instrumentação , Coração Auxiliar , Modelos Cardiovasculares , Fluxo Pulsátil/fisiologia , Metabolismo Energético , Hemodinâmica , Humanos , Lactente , Perfusão/instrumentação , Projetos Piloto
5.
ASAIO J ; 54(3): 306-15, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18496282

RESUMO

This investigation compared pressure drops and surplus hemodynamic energy (SHE) levels in eight commercially available pediatric aortic cannulae (10 Fr) with different geometries during pulsatile and nonpulsatile perfusion conditions in an in vitro infant model of cardiopulmonary bypass. For each trial, the cannula was placed at the distal end of the arterial line, and the insertion tip was fixed to the inlet of the simulated patient. The pseudo patient was subjected to seven pump flow rates ranging from 400 to 1000 ml/min (at 100 ml/min increments), and the mean arterial pressure was set at a constant 40 mm Hg via Hoffman clamp. Of the eight cannulae, the Surgimedics and THI models had significantly larger pressure drops (48.8 +/- 0.3 mm Hg and 48.3 +/- 1.4 mm Hg, respectively; 600 ml/min pulsatile) compared with the RMI cannula (27.6 +/- 1.2 mm Hg; 600 ml/min pulsatile), which created, on average, half of the pressure drop seen in the poorest performing cannulae. When perfusion mode was switched from nonpulsatile to pulsatile, there was a 7-9 fold increase in delivery of SHE recorded at both the pre- and postcannulae sites, regardless of which cannula was being tested. Despite being classified under the same size (10 Fr), these eight cannulae were found to vary considerably in length, inner diameter, and geometrical design. The results suggest that these differences can have a significant impact on pressure drops, as well as generation and delivery of SHE. Furthermore, it was found that pulsatile perfusion produced more "extra" hemodynamic energy when compared with nonpulsatile perfusion, regardless of cannula model.


Assuntos
Ponte Cardiopulmonar/instrumentação , Cateterismo , Modelos Cardiovasculares , Engenharia Biomédica , Ponte Cardiopulmonar/métodos , Desenho de Equipamento , Hemodinâmica , Humanos , Técnicas In Vitro , Lactente , Perfusão/instrumentação , Fluxo Pulsátil
6.
ASAIO J ; 54(3): 316-24, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18496283

RESUMO

The objective of this study was to detect and classify the number and size of gaseous microemboli in a simulated pediatric model of cardiopulmonary bypass. Tests were conducted at five different flow rates (400-1,200 ml/min in 200 ml/min increments), pulsatile versus nonpulsatile perfusion modes, and under normothermic, hypothermic, and deep hypothermic (35 degrees C, 25 degrees C, and 15 degrees C) conditions, yielding 180 total experiments. The circuit was primed with lactated Ringer's solution and filled with heparinized bovine blood. At the beginning of each experiment, 5 ml of air were injected into the venous line via the luer port of the oxygenator. Microemboli were quantified and classified by size for 5 minute segments at three transducer sites: postpump, postoxygenator, and postarterial filter. The purge line of the arterial filter was closed during all experiments. In all but one experiment, 90% of emboli at the postpump site were found to be smaller than 40 microm. At the postarterial filter site, nearly 99% of the emboli were smaller than 40 microm. Additionally, increasing microemboli counts were observed when the flow rate was increased and when the temperature was decreased. Lower temperatures, higher flow rates, and pulsatile perfusion were all associated with higher emboli counts. The majority of gaseous microemboli found in the simulated circuit was significantly below 40 microm; the smallest level detectable by traditional Doppler devices.


Assuntos
Ponte Cardiopulmonar/efeitos adversos , Embolia Aérea/diagnóstico por imagem , Embolia Aérea/etiologia , Animais , Engenharia Biomédica , Lesões Encefálicas/etiologia , Ponte Cardiopulmonar/métodos , Bovinos , Embolia Aérea/classificação , Humanos , Hipotermia Induzida , Técnicas In Vitro , Recém-Nascido , Modelos Cardiovasculares , Fluxo Pulsátil , Temperatura , Ultrassonografia
7.
ASAIO J ; 53(6): 706-9, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-18043152

RESUMO

Multiple factors influence the outcome of cardiopulmonary bypass (CPB) procedures in pediatric patients with congenital heart defects. The benefit of pulsatile over nonpulsatile perfusion is one such factor that continues to be widely debated among researchers, perfusionists, and surgeons. However, by accurately measuring pulsatile flow in terms of energy equivalent pressure and surplus hemodynamic energy, pulsatile perfusion is clearly seen to replicate the physiologic heart in a manner unparalleled by nonpulsatile perfusion. Studied benefits of pulsatile perfusion in pediatric patients include increased vital organ blood flow and improvement in postoperative recovery. Also, the components of the extracorporeal circuit used in CPB are directly related to pulsatility and have a profound effect on hemodynamics in the circuit and the patient. Therefore, pulsatility and surplus hemodynamic energy delivery to the patient can be maximized by choosing the best performing heart-pumps, oxygenators, arterial filters, and cannulae. Furthermore, in using the most optimal circuit components available, the CPB procedure under pulsatile perfusion can proceed efficiently. Currently, the outcomes resulting from pulsatile perfusion in pediatric and adult patients, as well as animal models, are well documented. However, more multilaboratory efforts are necessary to understand and further validate the benefits of pulsatile perfusion in pediatric patients.


Assuntos
Ponte Cardiopulmonar/métodos , Fluxo Pulsátil , Velocidade do Fluxo Sanguíneo , Pressão Sanguínea , Procedimentos Cirúrgicos Cardíacos/métodos , Circulação Cerebrovascular , Pré-Escolar , Metabolismo Energético , Oxigenação por Membrana Extracorpórea/métodos , Humanos , Lactente , Recém-Nascido , Perfusão/métodos