Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Am Coll Cardiol ; 58(11): 1140-9, 2011 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-21884952

RESUMO

OBJECTIVES: The purpose of this study was to determine the prognostic value of strain-encoded magnetic resonance imaging (SENC) during high-dose dobutamine stress cardiac magnetic resonance imaging (DS-MRI) compared with conventional wall motion readings. BACKGROUND: Detection of inducible ischemia by DS-MRI on the basis of assessing cine images is subjective and depends on the experience of the readers, which may influence not only the diagnostic classification but also the risk stratification of patients with ischemic heart disease. METHODS: In all, 320 consecutive patients with suspected or known coronary artery disease underwent DS-MRI, using a standard protocol in a 1.5T MR scanner. Wall motion abnormalities (WMA) and myocardial strain were assessed at baseline and during stress, and outcome data including cardiac deaths, nonfatal myocardial infarctions ("hard events"), and revascularization procedures performed >90 days after the MR scans were collected. RESULTS: Thirty-five hard events occurred during a 28 ± 9 month follow-up period, including 10 cardiac deaths and 25 nonfatal myocardial infarctions, and 32 patients underwent coronary revascularization. Using a series of Cox proportional-hazards models, both resting and inducible WMA offered incremental information for the assessment of hard cardiac events compared to clinical variables (chi-square = 13.0 for clinical vs. chi-square = 26.1 by adding resting WMA, p < 0.001, vs. chi-square = 39.3 by adding inducible WMA, p < 0.001). Adding visual SENC or quantitative strain rate reserve to this model further improved the prediction of outcome (chi-square = 50.7 vs. chi-square = 52.5, p < 0.001 for both). In a subset of patients (n = 175) who underwent coronary angiography, SENC yielded significantly higher sensitivity for coronary artery disease detection (96% vs. 84%, p < 0.02), whereas specificity and accuracy were not significantly different (88% vs. 94% and 93% vs. 88%, p = NS for both). CONCLUSIONS: Strain-encoded MRI aids the accurate identification of patients at high risk for future cardiac events and revascularization procedures, beyond the assessment of conventional atherogenic risk factors and resting or inducible WMA on cine images. (Strain-Encoded Cardiac Magnetic Resonance Imaging as an Adjunct for Dobutamine Stress Testing; NCT00758654).


Assuntos
Doença da Artéria Coronariana/diagnóstico , Ecocardiografia sob Estresse , Imagem Cinética por Ressonância Magnética , Idoso , Angiografia Coronária , Doença da Artéria Coronariana/mortalidade , Dobutamina , Feminino , Alemanha/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Análise de Sobrevida
2.
Catheter Cardiovasc Interv ; 76(4): 502-10, 2010 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-20882653

RESUMO

PURPOSE: To determine whether quantification of myocardial blush grade (MBG) during cardiac catheterization can aid the determination of follow-up left ventricular (LV)-function in patients with ST-elevation and non-ST-elevation myocardial infarction (STEMI and NSTEMI). METHODS: We prospectively examined patients with first STEMI (n = 46) and NSTEMI (n = 49). ECG-gated angiographic series were used to quantify MBG by analyzing the time course of contrast agent intensity rise. Hereby, the parameter G(max)/T(max) was calculated, derived from the plateau of grey-level intensity (G(max)), divided by the time-to-peak intensity (T(max)). Cardiac magnetic resonance imaging (CMR) deemed as the standard reference for the estimation of infarct size, transmurality and of the LV-function at 6 months of follow-up. RESULTS: Cut-off values of G(max)/T(max)=5.7/sec and 3.8/sec, respectively, yielded similar accuracy as infarct transmurality for the prediction of follow-up ejection fraction >55% (AUC = 0.86 for STEMI and AUC = 0.90 for NSTEMI, by G(max)/T(max) and AUC = 0.85 for STEMI and AUC = 0.89 for NSTEMI, by infarct transmurality, respectively, P = NS). Both clearly surpassed the predictive value of visual MBG (AUC = 0.69 for STEMI and AUC = 0.68 for NSTEMI, P < 0.05). CONCLUSION: G(max)/T(max) is an easy to acquire but highly valuable surrogate parameter for infarct size, which yields equally high accuracy with infarct transmurality and favorably compares with visually assessed blush grades for the prediction of follow-up LV-function in patients with acute ischemic syndromes.


Assuntos
Síndrome Coronariana Aguda/diagnóstico por imagem , Angiografia Coronária , Circulação Coronária , Infarto do Miocárdio/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Miocárdio/patologia , Função Ventricular Esquerda , Síndrome Coronariana Aguda/patologia , Síndrome Coronariana Aguda/fisiopatologia , Síndrome Coronariana Aguda/terapia , Idoso , Meios de Contraste , Feminino , Alemanha , Humanos , Imagem Cinética por Ressonância Magnética , Masculino , Microcirculação , Pessoa de Meia-Idade , Infarto do Miocárdio/patologia , Infarto do Miocárdio/fisiopatologia , Infarto do Miocárdio/terapia , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Prospectivos , Interpretação de Imagem Radiográfica Assistida por Computador , Recuperação de Função Fisiológica , Reprodutibilidade dos Testes , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento
3.
J Am Coll Cardiol ; 56(15): 1225-34, 2010 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-20883929

RESUMO

OBJECTIVES: This study sought to determine the prognostic value of wall motion and perfusion assessment during high-dose dobutamine stress (DS) cardiac magnetic resonance imaging (MRI) in a large patient cohort. BACKGROUND: DS-MRI offers the possibility to integrate myocardial perfusion and wall motion analysis in a single examination for the detection of coronary artery disease (CAD). METHODS: A total of 1,493 consecutive patients with suspected or known CAD underwent DS-MRI, using a standard protocol in a 1.5-T magnetic resonance scanner. Wall motion and perfusion were assessed at baseline and during stress, and outcome data including cardiac death, nonfatal myocardial infarction ("hard events"), and "late" revascularization performed >90 days after the MR scans were collected during a 2 ± 1 year follow-up period. RESULTS: Fifty-three hard events, including 14 cardiac deaths and 39 nonfatal infarctions, occurred during the follow-up period, whereas 85 patients underwent "late" revascularization. Using multivariable regression analysis, an abnormal result for wall motion or perfusion during stress yielded the strongest independent prognostic value for both hard events and late revascularization, clearly surpassing that of clinical and baseline magnetic resonance parameters (for wall motion: adjusted hazard ratio [HR] of 5.9 [95% confidence interval (CI): 2.5 to 13.6] for hard events and of 3.1 [95% CI: 1.7 to 5.6] for late revascularization, and for perfusion: adjusted HR of 5.4 [95% CI: 2.3 to 12.9] for hard events and of 6.2 [95% CI: 3.3 to 11.3] for late revascularization, p < 0.001 for all). CONCLUSIONS: DS-MRI can accurately identify patients who are at increased risk for cardiac death and myocardial infarction, separating them from those with normal findings, who have very low risk for future cardiac events. (Prognostic Value of High Dose Dobutamine Stress Magnetic Resonance Imaging; NCT00837005).


Assuntos
Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/fisiopatologia , Dobutamina/administração & dosagem , Teste de Esforço/efeitos dos fármacos , Imagem de Perfusão do Miocárdio/métodos , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Relação Dose-Resposta a Droga , Teste de Esforço/métodos , Feminino , Seguimentos , Humanos , Angiografia por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/fisiopatologia , Prognóstico , Estudos Prospectivos
4.
Am Heart J ; 159(4): 643-651.e2, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20362724

RESUMO

BACKGROUND: Cardiac allograft vasculopathy (CAV) progressively compromises microvascular perfusion and function in heart transplantation (HTx)-recipients. The aim of our study was to investigate the ability of quantitative myocardial blush grade (MBG) to detect CAV. METHODS: In consecutive HTx-recipients (n = 72) who underwent surveillance cardiac catheterization, MBG was assessed visually and quantitatively, by analyzing the time course of contrast agent intensity rise. Hereby, the parameter G(max)/T(max) was calculated as the plateau of grey-level intensity (G(max)) divided by the time-to-peak intensity (T(max)). HTx-recipients and 18 healthy volunteers underwent cardiac magnetic resonance, to assess diastolic strain rates and myocardial perfusion reserve during pharmacologic hyperemia. RESULTS: Significant correlations were observed between G(max)/T(max) with perfusion reserve and with mean diastolic strain rates (r(2) = 0.68 and r(2) = 0.58, P < .001 for both). Visual and quantitative MBG using a cutoff value of G(max)/T(max) = 2.7/s yielded significantly higher accuracy than stenosis severity on coronary angiograms for the detection of impaired microvascular integrity as a surrogate marker for CAV (AUC = 0.78, SE = 0.06, 95% CI = 0.66-0.87 for lumen narrowing versus AUC = 0.91, SE = 0.03, 95%CI = 0.84-0.97 for G(max)/T(max); P < .01). Furthermore, quantitative MBG provided more robust prediction of survival (chi(2)= 14.0, P < .001), compared to visually estimated blush (chi(2)= 5.4, P = .02) and to coronary lumen narrowing assessment, (chi(2)= 4.8, P = .04). CONCLUSIONS: Quantification of MBG can be performed on coronary angiograms of HTx-recipients, and may help with the identification of early CAV in patients with impaired perfusion reserve but without angiographically evident atherosclerosis.


Assuntos
Doença da Artéria Coronariana/patologia , Circulação Coronária , Transplante de Coração , Adulto , Idoso , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Sobrevivência de Enxerto , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Transplante Homólogo
5.
J Magn Reson Imaging ; 29(5): 1053-61, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19388131

RESUMO

PURPOSE: To investigate regional strain response during high-dose dobutamine stress cardiac magnetic resonance imaging (DS-CMR) using myocardial tagging and Strain-Encoded MR (SENC). MATERIALS AND METHODS: Stress induced ischemia was assessed by wall motion analysis, by tagged CMR and by SENC in 65 patients with suspected or known CAD who underwent DS-CMR in a clinical 1.5 Tesla scanner. Coronary angiography deemed as the standard reference for the presence or absence of CAD (> or =50% diameter stenosis) in all patients. RESULTS: SENC and conventional tagging detected abnormal strain response in six and five additional patients, respectively, who were missed by cine images and proved to have CAD by angiography (P < 0.05 for SENC versus cine, P = 0.06 for tagging versus cine and p = NS for SENC versus tagging). On a per-vessel level, wall motion analysis on cine images showed high specificity (95%) but moderate sensitivity (70%) for the detection of CAD. Tagging and SENC yielded significantly higher sensitivity of 81% and 89%, respectively (P < 0.05 for tagging and P < 0.01 for SENC versus wall motion analysis, and p = NS for SENC versus tagging), while specificity was equally high (96% and 94%, respectively, P = NS for all). CONCLUSION: Both the direct color-coded visualization of strain on CMR images and the generation of additional visual markers within the myocardium with tagged CMR represent useful adjuncts for DS-CMR, which may provide incremental value for the detection of CAD in humans. J. Magn. Reson.


Assuntos
Algoritmos , Doença da Artéria Coronariana/diagnóstico , Dobutamina , Técnicas de Imagem por Elasticidade/métodos , Teste de Esforço , Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Coloração e Rotulagem , Vasodilatadores
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...